IMAGING OBSERVATION SYSTEM USING CMOS IMAGE SENSOR (CMOS 영상센서를 이용한 영상관측장비 활용)

  • Jin, Ho;Park, Young-Sik;Park, Jang-Hyun;Yuk, In-Soo;Seon, Kwang-Il;Nam, Wook-Won;Han, Won-Yong;Lee, Woo-Baik;Lee, Sung-Woon;Shin, Young-Hoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.231-238
    • /
    • 2001
  • A prototype CMOS (complementary metal oxide semiconductor) imaging system has been built and the possibility of applying to the application to astronomical observations has been investigated. The CCD (charge coupled device) image sensor has been the mainstay of image capture and astronomical imaging for the last 30 years, but CMOS devices have shown rapidly increasing success and have been adapted to many commercial imaging systems . Although the photometric performances and system noise of CMOS sensors are lower than that of CCD image sensors, CMOS Imaging system can be used to obtain general image capture for astronomical applications.

  • PDF

기획특집 (3)_3D 디스플레이 산업의 동향 - 3D 영상 관련 장비 기술 및 업체 현황

  • Lee, Seung-Hyeon
    • The Optical Journal
    • /
    • s.126
    • /
    • pp.34-38
    • /
    • 2010
  • 최근 할리우드를 중심으로 디지털 3D 시네마가 일반화되고 있으며, 삼성, LG를 비롯한 국내외 기업들이 적극적으로 3D 시장에 뛰어들기 시작했다. 3D는 단순히 영상분야 뿐만이 아닌 전 분야에 걸쳐 파급효과가 있는 융합형 IT 산업임에 틀림없다. 본 고에서는 이러한 3D 영상 촬영을 위한 장비 기술과 업체 현황에 대해 소개하고자 한다.

  • PDF

Development of 4K UHD Graphic Moving Pattern Generator for Testing 4K UHD broadcast Equipment (방송장비 시험을 위한 4K UHD 그래픽 동영상 패턴발생장비 개발)

  • Kwak, Kyungchul;Yang, Jinyoung;Shin, Soogeun;Kwon, Donghyun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.384-387
    • /
    • 2016
  • 본 논문에서는 4K UHD 방송장비 중 디스플레이기기와 인코더의 성능 시험을 위해 개발된 패턴 발생장비를 소개하고 있다. 패턴의 제작 및 재생 방법에 따라 표출되는 패턴의 종류를 그래픽/실사, 정지/동영상으로 구분할 수 있는데 본 논문에서는 모션블러, 모션져더, AV lip sync, 텍스트 주변 인코딩 화질 열화 확인, 화이트 노이즈, 프레임 누락, HDR 확인, 지연시간 측정, 계단현상 확인, 이미지 스티킹 등 그래픽 동영상 패턴에 대해 각각의 제작 의도를 설명하고 이를 통해 디스플레이기기와 인코더의 성능을 평가하는 방법에 대한 간략한 소개와 개발된 패턴발생장비의 입출력 사양을 제시하고 있다.

  • PDF

Implementation of Wireless Stereoscopic Image Player for PC (PC용 무선 입체 영상 재생 장치 구현)

  • Kim, Kyong-Won;Cho, Hwa-Hyun;Kwon, Byong-Heon;Choi, Myung-Ryul
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05a
    • /
    • pp.555-558
    • /
    • 2003
  • 본 논문에서는 PC용 투선 입체 영상 재생 장치의 원리를 제안하고 설계 및 구현하였다. 무선 LCD(Liquid Crystal Display) 셔터 고글은 적외선 방식을 이용하였다. 본 장비는 유선 장비에 비교하여 자유로운 활동을 보장하며 다수의 사용자가 별도 추가장비 없이 입체 영상을 감상할 수 있다. 본 논문에서는 입체 영상 원리, 입체 영상 재생 모드, 투선 LCD 셔터 고글 동작을 논하였다. 무선 LCD 모니터용 입체 영상 재생 장치의 필요성과 향후 연구 방향을 제시하였다.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Dose and Image Evaluations of Imaging for Radiotherapy (방사선치료를 위한 영상장비의 선량 및 영상 평가)

  • Lee, Hyounggun;Yoon, Changyeon;Kim, Tae Jun;Kim, Dongwook;Chung, Weon Kyu;Park, Sung Ho;Lee, Wonho
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.292-302
    • /
    • 2012
  • The patient dose in advanced radiotherapy techniques is an important issue. These methods should be evaluated to reduce the dose in diagnostic imaging for radiotherapy. Especially, the Computed Tomography in radiotherapy has been used widely; hence the CT was evaluated for dose and image in this study. The evaluations for dose and image were done in equal condition due to compare the dose and image simultaneously. Furthermore, the possibility of dose and image evaluations by using the Monte Carlo simulation MCNPX was confirmed. We made the iterative reconstruction for low dose CT image to elevate image quality with Maximum Likelihood Expectation Maximization; MLEM. The system we developed is expected to be used not only to reduce the patient dose in radiotherapy, also to evaluate the overall factors of image modalities in industrial research.

기획특집 1: 군사용 전자광학 기술의 현재와 미래 -전자광학기술의 군사적 응용 및 전망

  • Hong, Seok-Min
    • The Optical Journal
    • /
    • s.130
    • /
    • pp.18-24
    • /
    • 2010
  • 군사용 전자광학장비는 1970년대 중반부터 국방과학연구소를 중심으로 관련 방산업체들이 협력하여 연구개발한 결과, 비교적 짧은 시간에 선진국 수준의 기술들이 확보되었다. 특히 생산된 전자광학장비는 군의 감시정찰 능력 증대에 활용되었고 대부분의 전술급 감시정찰 영상 장비나 사격통제용 영상센서들이 이제는 독자 개발, 생산되고 있다. 전자광학장비는 선진국에 비해 비용대비 투자 효과면에서 우위를 점하고 있기 때문에 국내 수요 뿐 아니라 세계시장을 겨냥한 수출을 적극적으로 추진해야 할 시점으로 보여지며 기술 확보를 위한 방산전문업체와 우수 중소기업의 참여 확대가 요구되고 있다.

  • PDF

SDR-HDR image conversion and considerations from post-production perspective (후반 작업 관점에서 본 SDR-HDR 영상 변환과 고려사항)

  • Kim, Ji-Hyeon
    • Broadcasting and Media Magazine
    • /
    • v.22 no.3
    • /
    • pp.69-75
    • /
    • 2017
  • SDR 영상과 함께 HDR 버전 제작을 함께 요청하는 프로젝트가 점점 늘어나는 추세다. 어느 정도 규모의 업체에서는 고가의 HDR 레퍼런스 모니터와 라이선스 비용을 지불하고 비교적 편리하게 작업할 수 있다. 상황이 그렇지 못할 경우 최소의 비용으로 장비를 구매하고, 기존 장비와 호환성을 점검하고, 컬러링 어플리케이션에서 지원하는 기능을 활용하여 최선의 워크플로를 구성해야 한다. 또한 SDR 버전을 HDR 버전으로 제작하거나 HDR 영상을 SDR 버전으로 변환할 때 장면마다 다시 보정하는 일을 최소화하기 위한 세심한 보정이 필요하다. 본 원고에서는 동시에 촬영된 BT.709 기반의 HD 프록시 영상과 RAW로 촬영된 UHD 원본 영상을 활용하여 변환 작업에서 주의 깊게 살펴보아야 할 사항들을 알아보도록 하겠다.

The development of digital camera for the medical DF instrument (의료용 DF 장비의 디지털 카메라 개발)

  • 김용민;이성운;구기현;김진용;김승식;문지영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.76-77
    • /
    • 2003
  • Digital Radiograpy & Fluoroscopy(DRF 또는 DR 또는 DF)는 cone beam을 이용하여 인체를 투과한 X선을 영상증배관(Image Intensifying Tube: IIT)을 통하여 가시광선으로 변환시킨 후 영상을 카메라로 보내고, 이곳에서 발생한 영상정보를 디지털로 처리하여 모니터를 통해 눈에 보이는 영상으로 만드는 방법으로 IIT에 기초한 디지털 방사선 촬영술이라고도 한다. DF 방법은 즉시 영상 표시와 진단이 가능하기 때문에 즉시성이 요구되는 심장이나 두복부 등의 순환기 분야에서 DSA(Digital Subtraction Angiography) 장비로 이용되고 있고, 순환기뿐만 아니라 위를 중심으로 한 소화관(식도, 위, 소장, 대장, 직장)의 분야에서 적용 가능하다. (중략)

  • PDF

핵의학 DICOM 영상 Data 분석

  • Kim, Sae-Rom;Jeong, Hae-Jo;Seong, Min-Mo;Choe, Seung-Uk;Jang, Bong-Mun;Yang, Geon-Ho;Kim, Hui-Jung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.108-112
    • /
    • 2004
  • 현재 많은 병원의 핵의학과에서 핵의학 장비를 이용하여 많은 수의 핵의학영상을 생성하고 있다. 생성된 핵의학영상은 환자의 질병을 진단 또는 치료하기 위해 기능적 정보를 많이 포함하고 있다. 하지만 이렇게 중요한 기능적 정보가 현재의 PACS 에서는 그 중요한 기능적 정보를 모두 표현하지 못 하는 문제점이 있다. DICOM 에서는 핵의학 영상 및 데이터에 대하여 표준을 정해놓고 그 표준을 따르도록 규정하고 있다. 이러한 DICOM 3.0 표준에서 핵의학 영상 및 데이터에 대하여 표준을 정해놓은 일은 비교적 최근의 일이어서 많은 수의 핵의학 영상 장비나 PACS에서는 핵의학영상에 대한 특징이 반영되지 않고 있는 실정이다. 이에 핵의학 영상의 호환성을 향상과 PACS와 핵의학 장비간의 호환성을 향상시키기 위하여 DICOM 3.0 Part 3에 정의된 IOD 중 꼭 필요하다고 생각되는 최소한의 Tag들을 선별하여 Guideline을 작성하여 DICOM 영상을 Guideline의 내용을 토대로 분석하였고 핵의학 영상이 PACS에서 제대로 활용되지 못 하는 원인을 분석 하였다.

  • PDF