• Title/Summary/Keyword: 영상신호 분석

Search Result 1,007, Processing Time 0.026 seconds

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Evaluation of Fibrosis in Liver Cirrhosis by Superparamagnetic Iron Oxide (SPIO)-Enhanced MR Imaging: Does the Radiological Non-Invasive Fibrosis Index Correlate with the Laboratory Non-Invasive Fibrosis Index? (Superparamagnetic Iron Oxide-Enhanced MRI를 이용한 간섬유화의 평가: 영상의학적 비침습적 간섬유화 지표가 AST/혈소판 비와 상관 관계가 있는가?)

  • Kim, Shin-Kee;Lee, Chang-Hee;Kim, Kyeong-Ah;Choi, Jae-Woong;Lee, Jong-Mee;Park, Cheol-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2008
  • Purpose : To evaluate the correlation between the radiological non-invasive hepatic fibrosis index (RNHFI), as determined by SPIO-enhanced MRI, and the laboratory non-invasive hepatic fibrosis index. Materials and Methods : Patients (99 total: 61 men and 38 women; mean age: 58 years) who underwent SPIO-enhanced MRI (1.5T) during 5 years included. These patients were subdivided into a liver cirrhosis group (LCG) and a non-liver cirrhosis group (non-LCG). Using PACS view, we measured the RNHFI (mean standard deviation of hepatic signal intensity (SD), noise-corrected coefficient of variation (CV)) of three ROIs in the liver parenchyma by SPIO-enhanced MRI. The laboratory non-invasive hepatic fibrosis index (AST-platelet ratio index (APRI)) of all patients was calculated from the laboratory data. We compared the RNHFI and APRI of LCG with those of non-LC group using Student's t-test. A bivariate correlation was performed to investigate the relationship between the RNHFI and APRI in the LCG. Results : For the LCG, mean values of SD and CV by SPIO-enhanced MRI were $10.3{\pm}3.7$ and $0.19{\pm}0.08$, respectively. For the non-LCG, mean values of SD and CV were $6.5{\pm}1.6$ and $0.08{\pm}0.05$, respectively. The mean APRI of the LCG and the non- LCG were $2.04{\pm}1.7$ and $0.32{\pm}0.32$, respectively. The RNHFI and APRI were significantly different between both groups (p<0.05). For the LCG, the bivariate correlation between SD and APRI revealed a statistically significant positive correlation (r=0.5, p<0.001). In both groups, there was no statistically significant correlation between CV and APRI. Conclusion: A measurement of SD can be a simple and useful method for the evaluation of hepatic fibrosis.

  • PDF

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

BOLD Responses to Acupuncture on Each Side of ST36 (족삼리 좌우측 자침에 대한 BOLD 반응)

  • Yeo, Sujung;Bae, Seong-In;Choe, Ilwhan;Jahng, Geon-Ho;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.31 no.1
    • /
    • pp.20-32
    • /
    • 2014
  • Objectives : There has been some controversy about the modulatory effects on brain function during acupuncture on each side of the same acupoint. This study was designed to investigate and compare the blood oxygen level-dependent(BOLD) responses of acupuncture on each side of ST36. Methods : Fourteen healthy subjects were recruited for imaging and received acupuncture or placebo stimulations either on the left or on the right acupoint of ST36 in each scan. For the voxel-wise statistical analysis, one sample T-test and the within-subject analysis of variance(ANOVA) test were performed using SPM8 software. Results : This study showed that acupuncture on each side of ST36 showed different BOLD signal patterns. Higher BOLD responses after acupuncture stimulations at the left ST36 compared to the right were observed mainly in the parahippocampal gyrus(BA 28), dorsolateral prefrontal cortex(DLPFC, BA 44), thalamus, culmen and claustrum. We investigated the different neural responses between rest and activation periods of placebo and acupuncture stimulations on each side of ST36. Acupuncture at the right ST36 elicited activation mainly in the insula, supplementary motor area(SMA) and anterior cingulate cortex(ACC), while acupuncture at the left ST36 elicited activation mainly in the insula, primary somatosensory cortex(SI, BA 2) and DLPFC(BA 44). Conclusions : To our knowledge, this is the first reported functional MRI study directly comparing when needling at the right and at the left side of ST36. This study's preliminary results proved to be evidence of acupuncture's different effects when performed on opposite sides of an acupoint.

Application of Borehole Radar to Tunnel Detection (시추공 레이다 탐사에 의한 지하 터널 탐지 적용성 연구)

  • Cho, Seong-Jun;Kim, Jung-Ho;Kim, Chang-Ryol;Son, Jeong-Sul;Sung, Nak-Hun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.279-290
    • /
    • 2006
  • The borehole radar methods used to tunnel detection are mainly classified into borehole radar reflection, directional antenna, crosshole scanning, and radar tomography methods. In this study, we have investigated the feasibility and limitation of each method to tunnel detection through case studies. In the borehole radar reflection data, there were much more clear diffraction signals of the upper wings than lower wings of the hyperbolas reflected from the tunnel, and their upper and lower wings were spreaded out to more than 10m higher and lower traces from the peaks of the hyperbolas. As the ratio of borehole diameter to antenna length increases, the ringing gets stronger on the data due to the increase in the impedance mismatching between antennas and water in the boreholes. It is also found that the reflection signals from the tunnel could be enhanced using the optimal offset distance between transmitter and receiver antennas. Nevertheless, the borehole radar reflection data could not provide directional information of the reflectors in the subsurface. Direction finding antenna system had a advantage to take a three dimensional location of a tunnel with only one borehole survey even though the cost is still very high and it required very high expertise. The data from crosshole scanning could be a good indicator for tunnel detection and it could give more reliable result when the borehole radar reflection survey is carried out together. The images of the subsurface also can be reconstructed using travel time tomography which could provide the physical property of the medium and would be effective for imaging the underground structure such as tunnels. Based on the results described above, we suggest a cost-effective field procedure for detection of a tunnel using borehole radar techniques; borehole radar reflection survey using dipole antenna can firstly be applied to pick up anomalous regions within the borehole, and crosshole scanning or reflection survey using directional antenna can then be applied only to the anomalous regions to detect the tunnel.

A Study on the Digital Decipherment of the Goguryeo Stele in Chungju (충주고구려비(忠州高句麗碑) 디지털 판독의 성과와 고찰)

  • JO, Younghoon;KWON, Dakyung;AHN, Jaehong;KO, Kwangeui
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.240-253
    • /
    • 2021
  • Various decipherment technologies, including manual rubbing, have been continuously applied to the Goguryeo Stele in Chungju. However, an official document for advanced decipherment is required as there remain characters to be deciphered. This study focuses on interdisciplinary digital decipherment using digital visualization results based on reflectance transformation imaging and three-dimensional scanning. On that basis, the joint decipherment document in 2019 is classified into eight types according to character changes from 1979 to 2000, and decipherment achievements are discussed. Important outcomes of the joint decipherment document include a new interpretation of four existing characters and the identification of 28 new characters. Additionally, 68 characters on the front face and 20 on the left face, which are listed differently in previous decipherment documents, are determined to be a single character through a consensus process. Compared to the previous decipherment document, the "decision" character is increased by a total of 89 characters (22.6%), and the "different opinion" character is decreased by 126 characters (32.0%). Thus, this digital decipherment greatly contributes to the reexamination of the Goguryeo Stele in Chungju and complements the previous decipherment document through reflectance transformation imaging and three-dimensional scanning. However, continuous research is necessary to enhance decipherment rates, since 123 characters (31.3%) are yet to receive decipherment. In the future, decipherment advancement regarding the Goguryeo Stele in Chungju should be based on convergence research between the humanities and science. Furthermore, it seems that researchers must make constant efforts to apply new imaging analysis technology and to develop customized technology for decipherment.

Estimation of High Resolution Sea Surface Salinity Using Multi Satellite Data and Machine Learning (다종 위성자료와 기계학습을 이용한 고해상도 표층 염분 추정)

  • Sung, Taejun;Sim, Seongmun;Jang, Eunna;Im, Jungho
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.747-763
    • /
    • 2022
  • Ocean salinity affects ocean circulation on a global scale and low salinity water around coastal areas often has an impact on aquaculture and fisheries. Microwave satellite sensors (e.g., Soil Moisture Active Passive [SMAP]) have provided sea surface salinity (SSS) based on the dielectric characteristics of water associated with SSS and sea surface temperature (SST). In this study, a Light Gradient Boosting Machine (LGBM)-based model for generating high resolution SSS from Geostationary Ocean Color Imager (GOCI) data was proposed, having machine learning-based improved SMAP SSS by Jang et al. (2022) as reference data (SMAP SSS (Jang)). Three schemes with different input variables were tested, and scheme 3 with all variables including Multi-scale Ultra-high Resolution SST yielded the best performance (coefficient of determination = 0.60, root mean square error = 0.91 psu). The proposed LGBM-based GOCI SSS had a similar spatiotemporal pattern with SMAP SSS (Jang), with much higher spatial resolution even in coastal areas, where SMAP SSS (Jang) was not available. In addition, when tested for the great flood occurred in Southern China in August 2020, GOCI SSS well simulated the spatial and temporal change of Changjiang Diluted Water. This research provided a potential that optical satellite data can be used to generate high resolution SSS associated with the improved microwave-based SSS especially in coastal areas.