• Title/Summary/Keyword: 영상검출기

Search Result 843, Processing Time 0.026 seconds

Development of Trans-Admittance Scanner (TAS) for Breast Cancer Detection (유방암 검출을 위한 생계 어드미턴스 스캐너의 개발)

  • 이정환;오동인;이재상;우응제;서진근;권오인
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.335-342
    • /
    • 2004
  • This paper describes a trans-admittance scanner for breast cancer detection. A FPGA-based sinusoidal waveform generator produces a constant voltage. The voltage is applied between a hand-held electrode and a scan probe placed on the breast. The scan probe contains an 8x8 array of electrodes that are kept at the ground potential. Multi-channel precision digital ammeters using the phase-sensitive demodulation technique were developed to measure the exit current from each electrode in the array. Different regions of the breast are scanned by moving the probe on the breast. We could get trans-admittance images of resistor and saline phantoms with an anomaly inside. The images provided the information on the depth and location of the anomaly. In future studies, we need to improve the accuracy through a better calibration method. We plan to test the scanner's ability to detect a cancer lesion inside the human breast.

Development of technique to detect weeds in paddy field using spectrophotometric analysis (분광특성 분석에 의한 논 잡초 검출법 개발)

  • 서규현;서상룡;성제훈
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.438-443
    • /
    • 2002
  • 본 연구는 수도작에서 토양과 식물체의 분광반사특성과 영상처리를 이용한 기계시각 잡초검출 센서를 개발하기 위한 기초연구로서 분류하고자 하는 대상체들의 분광반사율을 조사하여 주요한 파장을 선정하고 선정된 파장을 이용한 판별분석을 통해 각 대상체에 대한 분류 정확도를 중심으로 잡초검출 가능성을 조사하기 위하여 수행하였으며, 실험으로부터 얻은 결론은 다음과 같다. 1. 토양과 식물체를 구분하는데 효과적인 파장은 마른 토양의 경우 680 nm, 배수 토양에 있어서는 810 nm로 선정하였고, 토양을 배제한 후 벼와 잡초를 구분하기에 효과적인 파장은 580, 680 nm로 선정하였다. 2. 토양과 식물체를 구분하기 위한 판별분석 결과 2가지 토양상태 모두 식물체와 완전히 구분 가능한 것으로 나타났다. 벼와 잡초를 구분하기 위한 실험에서, 벼는 98%의 분류정확도로 구분이 가능하였고, 잡초는 83%의 분류정확도로 구분이 되는 것으로 나타났다. 따라서 차후 분광학적 원리를 이용한 센서를 제작할 때 본 연구에서 선택한 주요 파장과 판별함수를 이용하여 장치를 구성하고 알고리즘을 제작한다면 벼, 잡초, 토양을 효과적으로 구분이 가능할 것으로 판단되었다. 3. 컬러 CCD 카메라를 사용하는 경우에 있어 식물체와 토양을 구분하기 위해 3 종의 파장 중 630 nm 파장만의 이용을 고려하여 그 분류성능을 분석한 결과, 식물체와 토양은 소수의 관측치를 제외하고 완전히 구분이 가능했고, 벼와 잡초를 구분한 결과에서는 비교적 높은 분류능력을 가진 것으로 나타나 차후 컬러 CCD 카메라를 이용하여 장치를 구성하는데 좋은 기초가 될 것으로 판단된다. 배양체의 접종작업은 모든 배양실이 인력에 의존하였으며, 배양체를 배지와 분리하여 불필요한 부분을 제거하고 배양작물에 따라 생육정도를 2~3등급으로 구분하여 배양용기의 배지 위에 치상하는 과정으로 수행되었으며, 작업능률은 호접란의 경우 배양병에 25본을 접종하는데 시간당 6병, 심비디움은 원형 플라스크에 25본을 접종하는데 시간당 10병 정도였다. 바. 식물체의 대량증식에 사용되는 플라스크, 배양병, PE용기 등 배양용기의 세척작업은 농원의 1개배양실에서 간이식 세척기, 이 외의 9개배양실은 모두 물에 담겨 두었다가 세제와 브러쉬 등을 사용하여 인력으로 세척하고 있어 생력화 기술개발이 요구되었다.도가 빠를수록 건조속도가 빨라졌으며, 건조에너지도 1,334kcal/kg.water로 비슷하게 소요되었다. 마. 시험구와 대비구의 건감률은 시험구에서 1.08~1.36w.b./h로 나타나 대비구보다 약 9.9~18.3%가 높게 나타났고, 건조에너지는 10.2~14.6%가 절감되었다. 발아율은 열풍온도가 낮을수록 높게 나타났고 시험구가 대비구보다 발아율이 낮게 나타났으며, 동할률 증가량도 원적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을

  • PDF

Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment (MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가)

  • Sun, Geo Jun;Son, Sang Jun;Lee, Yang Hoon;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.169-176
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate clinical applicability of Co-60 ViewRay treatment plan to increase the skin dose in case of high skin dose is required such as Malignant Fungating Wound By measuring the presence / absence of Bolus application and skin dose by the treatment device and comparing it Materials and Methods : Nine inner measuring points of 2.5 cm lattice arrangement and all 13 measuring points including upper and lower left and right measuring points touching the chest and skin were marked. After CT was taken, each treatment plan was formulated through Eclipse and ViewRay-TPS, and a Fixed beam-IMRT treatment plan was formulated so that the left chest V2Gy=95 % is delivered. Before measurement QED detector was calibrated and the QED detector was positioned at the 13 measurement points displayed on Phantom and surface dose of each treatment planner was measured using 5 mm Bolus application using True-beam and View-ray before and after, measure three times and compare each before applying 5 mm Bolus. Results : The surface dose of the Co-60 ViewRay and the linear accelerator appeared at $76.8%{\pm}5.2%$ vs. $67.3{\pm}%7.5%$ and the surface dose after application of 5 mm Bolus was $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$ It was measured at 10.2 % (p<0.001). Conclusion : As a result of the surface dose measurement of each treatment instrument, Co-60 ViewRay confirmed that the surface dose reached 95.6 % of 6 MV Linac with conventional 5 mm bolus, despite not using Bolus (p<0.001). Also, by utilizing magnetic resonance images for each treatment, it is possible to observe the change in the treatment site without the problem of exposure, it is easy to formulate an adaptive treatment plan and it is easy to secure the skin dose, so the size In the case of Malignant Fungating Wound patients who need fast skin changes and need high skin doses, Co-60 ViewRay is considered to be more useful than linear accelerators.

  • PDF

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

Evaluation on Organ Dose and Image Quality by Changing kVp and Ion Chamber Combination while Taking Digital Chest Lateral Decubitus PA Projection (디지털 흉부 측와위 후전방향 검사 시 Ion chamber조합 설정과 관전압 변화에 따른 장기선량 및 화질 평가)

  • Lee, Jin-Soo;Park, Hyong-Hu
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.316-323
    • /
    • 2015
  • In this study, we analyzed radiation dose and MTF with setting of Ion chamber and changing kVp so that we are able to suggest acquiring optimized diagnostic images and minimizing patient dose. we assumed right lateral decubitus position among chest decubitus projection and set 7 combination of Ion chamber. By changing kVp(100, 110, 120, 130kVp), we exposed x-ray five times respectively and calculated average value after measuring entrance dose. we input the entrance dose value to PCXMC Monte carlo simulation tool and calculated organ dose and effective dose. Then we did physical image evaluation with MTF for the purpose to compare image quality. As a result, the high kVp, entrance dose is reduced. As change of ion chamber, when selecting second ion chamber, both organ dose and effective dose were the lowest. In contrast, selecting first ion chamber was the highest. MTF is superior to set second Ion chamber and using 120 kVp. Consequently, when taking chest right lateral decubitus using Digital radiography, the optimized combination which have both reducing dose efficiently without declining image quality and aquring good qualified image is set 120 kVp and selecting second Ion chamber.

Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector (디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구)

  • Kim, Byung-Ki;Kim, Sang-Keun;Cha, Seon-Hwa;Choi, Jun-Gu;Lee, Jun;Kim, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Sun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

Flight model development of the NISS structure for NEXTSat-1 payload

  • Moon, Bongkon;Ko, Kyeongyeon;Lee, Duk-Hang;Jeong, Woong-seob;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Kim, Mingyu;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.87.3-88
    • /
    • 2017
  • 한국천문연구원은 차세대소형위성 1호의 근적외선 영상분광기 NISS (Near-infrared Imaging Spectrometer for Star formation history) 탑재체를 개발하여 2017년 6월 30일에 최종 비행모델을 납품하였고, 이 발표는 탑재체 NISS 구조체의 비행모델 개발 결과를 보고한다. NISS는 0.9 - 2.5um (R~20) 근적외선 파장에서 관측을 해야 하기 때문에, 구조체의 배경잡음을 없애기 위해서 200K까지 passive cooling으로 냉각되며, H2RG 검출기는 소형 냉동기에 의해 약 88K에서 운영된다. NISS 구조체의 passive cooling을 효율적으로 수행하기 위해서 방열판, Kevlar 지지대, MLI, 표면제어용 필름 등을 조립하였고, 실제 지상 시험을 통해서 그 성능을 확인하였다. NISS 구조체는 최종 시스템 조립 과정에서 전자부 하네스 조립을 함께 수행했으며, 온도 모니터링 센서를 부착하고 소형 냉동기 피드백 온도를 반복 시험을 통해서 결정하였다. NISS 구조체는 미러 및 렌즈를 지지하는 광기계부를 함께 포함하기 때문에 발사 및 우주환경에서 광학 성능을 유지하기 위한 설계를 거쳐서 제작 되었으며, 최종 시스템 검교정 시험, 진동 및 열진공 시험을 통해서 그 성능을 확인하였다. NISS를 탑재한 차세대소형위성 1호는 2018년 상반기에 미국의 Falcon 9 발사체에 실려서 발사될 예정이다.

  • PDF

A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera (마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Song, Ha-Ryong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • Magnetic nondestructive testing is very useful far detecting a crack on the surface or near of the surface of the ferromagnetic materials. The distribution of the magnetic flux leakage (DMFL) on a specimen has to be obtained quantitatively to evaluate the crack. The magnetic camera is proposed to obtain the DMFL at the large lift-off. The magnetic camera consists of a magnetic source, magnetic lens, analog to digital converters (ADCs), interface, and computer. The magnetic leakage fields or the distorted magnetic fields from the object, which are concentrated on the magnetic lens, are converted to analog electrical signals tv arrayed small magnetic sensors. These analog signals are converted to digital signals by the ADCs, and are stored, imaged, and processed by the interface and computer. However the magnetic camera has limitations with respect to converting and switching speed, full range and resolution, direct memory access (DMA), temporary storage speed and volume because common ADCs were used. Improved techniques, such as those that introduce the operational amplifier (OP-Amp), amplify the signal, reduce the connection line, and use the low pass filter (LPF) to increase the signal to noise ratio are necessary. This paper proposes the exclusive embedded ADC including OP-Amp, LPF, microprocessor and DMA circuit for the magnetic camera to satisfy the conditions mentioned above.