• Title/Summary/Keyword: 영구적 인공심박동기

Search Result 5, Processing Time 0.026 seconds

Study on Recipients' Experience of Adapting to Permanent Pacemakers (영구적 인공심박동기 이식자의 적응 경험)

  • Han, Sun Hee;Kang, Jeong Hee
    • Journal of Korean Critical Care Nursing
    • /
    • v.11 no.3
    • /
    • pp.23-34
    • /
    • 2018
  • Purpose : This study develops a substantive theory on the recipients' experience of adapting to a permanent pacemaker. Method : The study used the grounded theory method developed by Strauss and Corbin (1998). The participants of the study were 13 adults who had received a permanent pacemaker during the previous year. The study addressed the research question "what is the experience of adaptation in people who had received permanent pacemakers?" From October 2016 to March 2017, data were collected from the participants through in-depth interviews. Results : The core category indicating the essence of the adaptation experience was shown to be "accepting the pacemaker as part of my body and living in line with it." Conclusions : In nursing practice, the results of this study will assist nurses in improving their communications with and developing guidelines or interventions for their clients who have received permanent pacemakers. In the field of nursing education, this study is expected to provide a framework to understand the experiences of future nurses and other healthcare workers working with permanent pacemaker recipients.

Cardiac Surgery for the Patient with VVI Unipolar Pacing System -One Case- (VVI 단극유도의 심박조율치를 가진 환자의 개심술 -1례 치험-)

  • 정해동;최종범;최형호
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.398-401
    • /
    • 1998
  • A 56-year-old female with a permanent unipolar pacing(VVI) system underwent elective coronary bypass surgery and mitral valve replacement. Because the unipolar sensing is subject to considerable nonmyocardial electrical noise, the pacing function may be disturbed by the use of electrocautery. Temporary atrial and ventricular bipolar epicardial leads and external generator were used for maintaining A-V sequential pacing during the use of electrocautery. Before aortic cross-clamp was released after cardiac operation, regular cardiac rhythm could spontaneously be resumed with an integrated cardioplegic strategy, avoiding the use of defibrillator

  • PDF

Thirteen-year Experience of Permanent Epicardial Pacing in Children (소아연령군에서의 영구 심외막 심박 조율 13년 경험)

  • 한국남;임홍국;김웅한;김용진;노준량;배은정;노정일;윤용수;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.499-503
    • /
    • 2004
  • Background: We investigated the longevity, thresholds of epicardial pacemaker and causes of reoperation in the pediatric patients who underwent epicardial pacemaker implantation performed during the last 13 years Material and Method: 121 operations were performed in 83 patients from January 1989 to July 2002. We analyzed the stimulation threshold, resistance, R-wave and P-wave, and sensitivity of pacemaker lead at initial implantation. Longevity and causes of reoperations were investigated. Result At implantation, epicardial ventricular mean stimula-tion threshold was 1.2$\pm$0.1 (0.1∼5) mV, mean resistance was 519.1$\pm$18.1 (319∼778) Ohm, and mean R-wave sensitivity was 8.9$\pm$0.7 (4∼20) mV, and mean P wave sensivity was 2.5$\pm$0.7 (0.4∼12) mV. The mean longe-vity of pacemaker generator was 64.7$\pm$3.7 (2∼196) months. The reoperation free rate was 94.6% for 1 year, 93.6% for 2 years, 80.8% for 5years, 63.7% for 7 years, and 45.5% for 10 years. The causes of reoperation were battery waste in 26 cases and lead malfunction in 9 cases. There was no postoperative death related to pacemaker malfunction. Conclusion: in the childrens, average longevity of epicardial pacemaker was within accep-table range. 19.1% of the patients required pacemaker related reoperation. However, recent developments, including steroid eluting lead, 6.7% of the patients required pacemaker related reoperation, look promising in expansion of pacemaker life span.

The Early Results of Tricuspid Valvuloplasty with Using the Edwards MC3 Annuloplasty System (Edwards MC3 Annuloplasty System을 이용한 삼첨판 성형술의 조기 성적)

  • Oh, Tak-hyuck;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik;Kim, Dae-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.28-33
    • /
    • 2009
  • Background: Functional tricuspid regurgitation (TR) greater than or equal to a mild grade requires tricuspid valvuloplasty, and tricuspid valvuloplasty with ring annuloplasty has shown good outcomes. We report here on our early experience with the Edwards $MC^3$ annuloplasty system (Edwards LifeSciences, Irvine, CA). Material and Method: From November 2004 to July 2006, 72 patients with tricuspid annular dilatation and TR underwent tricuspid valvuloplasty with using the Edwards $MC^3$ annuloplasty ring. Sixty-eight patients were operated on via median sternotomy and four patients were operated on using robotic assisted minimal invasive thoracotomy. The patient population included 21 males and 51 females and their mean age was $53.9{\pm}12.3$. The mean grade of TR, as assessed by the preoperative echocardiography, was $2.2{\pm}1.0$. The mean NYHA functional class was $3.1{\pm}0.8$. The mean left ventricular ejection fraction was $57.0{\pm}9.9$%. Result: The TR and NYHA functional class, as assessed by postoperative echocardiography, was significantly reduced (mean=$0.4{\pm}0.6$ and $2.0{\pm}0.7$, respectively p<0.001). There was one case of hospital mortality. One patient required permanent pacemaker insertion for third degree atrioventricular block. Conclusion: Our study shows that the Edwards $MC^3$ remodeling ring is easy to implant and it effectively corrects functional TR with excellent clinical and echocardiographic outcomes. Further follow-up and a larger clinical series are required to establish the long-term stability of this repair technique.

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF