• Title/Summary/Keyword: 염화물 침투시기

Search Result 9, Processing Time 0.024 seconds

Quantifying Chloride Ingress in Cracked Concrete Using Image Processing (이미지 분석을 이용한 균열 콘크리트 내 염화물 침투 정량화 평가)

  • Kim, Kun-Soo;Park, Ki-Tae;Kim, Jaehwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.57-64
    • /
    • 2022
  • Chloride, which is one of the main deterioration factors in reinforced concrete structures, can degrade the performance of the structure due to chloride-induced corrosion of steel. Chloride content at steel depth or the rate of chloride penetration is necessary to determine deterioration of reinforced concrete or to calculate initiation time of steel corrosion caused by chloride attack. Chlorides in concrete are generally identified with typical two methods including chloride profiling using potentiometric titration method and discoloration method using AgNO3 solution. The former is advantageous to estimate chloride penetration rate (diffusion coefficient in general) with measured chloride contents directly, but it is laborious. In the case of latter, while the result is obtained easily with the range of discoloration, the error may occur depending on workmanship when the depth of chloride ingress is measured. This study shows that chloride penetrated depth is evaluated with the results obtained from discoloration method through image analysis, thereby the error is minimized by workmanship. In addition, the effect of micro-crack in concrete is studied on chloride penetration. In conclusion, the depth of chloride penetration was quantified with image analysis and as it was confirmed that chlorides can rapidly penetrate through micro-cracks, caution is especially required for cracks in concrete structure.

Effects of Surface Material of Forms on Durability of Offshore Concrete (구조물의 표면마감 특성이 해양콘크리트의 내구성에 미치는 영향)

  • Park, Sang-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.233-240
    • /
    • 2008
  • This paper presents an experimental study on the air contents and the chloride penetration in offshore concrete depending on the types of forms. Three types of concretes(plain, MSF, and FA concretes) with four kinds of forms(wood, coating wood, steel, and polypropylene film) were investigated. The test results show that the air contents in the concrete cured with steel and polypropylene forms were higher than those with wood and coating wood forms. The concrete with wood forms has the least air content. The variation of chloride ingress time was large depending on the types of forms on the same concrete, i.e. 13.2, 20.3, and 17.7% for Plain, MSF, and FA concretes, respectively. Consequently, the surface conditions of forms should be considered for design of durable concrete.

The Analysis of Chloride Ions Intrusion into Concrete Structure (콘크리트 구조물의 염화물이온 침투거동 해석)

  • 김은겸;신치범;이윤한
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.6
    • /
    • pp.233-241
    • /
    • 1997
  • 최근 해안환경하에 있는 콘크리트구조물의 철근부식은 구조물의 내구성 저하 및 유지관리라는 차원에서 커다란 문제점을 가지고 있다. 이와 같은 현상은 해양구조물의 건설이 날로 증가하고 있고, 또 콘크리트 제조시 잔골재의 일부를 염분이 함유된 해사를 사용함으로써 더욱 심각해지고 있다. 본 연구에서는 콘크리트 표면으로부터 침투해 들어오는 침입염분의 거동을 모델화하였으며, 콘크리트 세공속의 수용액상에 있은 염화물이온의 확산을 포함하는 물리 화학적 진행, 시멘트 수화물에 고정되는 염분의 흡착과 탈착 및 고정염과의 화학반응 등의 현상을 유한요소법에 의해 해석을 실시하였다. 본 연구의 결과는 콘크리트 내부의 철근 발청시기의 예측, 해안환경하에 있는 콘크리트 구조물의 침투 염분에 의한 콘크리트 덮개의 결정, 콘크리트 구조물의 염화물이온의 허용치 설정을 비롯하여 내구년수를 예측하는데 유용하게 활용될 수 있을 것으로 기대된다.

Influence of Painting Materials based on Wasted Oil and Applying Timing on Carbonation and Chloride Resistances of High Volume SCM Concrete (폐유지류를 중심으로 한 도포제 종류 및 도포시기 변화가 혼화재 다량치환 콘크리트의 탄산화 및 염해저항성에 미치는 영향)

  • Han, Cheon-Goo;Choi, Young-Doo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.228-236
    • /
    • 2015
  • In this research, the influence of painting materials and applying timing on carbonation and chloride resistances of high volume SCMs concrete was evaluated. As a durability improving method, comparative tests were conducted with painting materials of ERCO (emulsified refined cooking oil), RCO (refined cooking oil), WR (water repellent agent), and ERCO + WR and with painting timings of right after demolding, and 28 days after the wet curing. From the experiment results, in the case of carbonation and chloride resistance, the carbonation depth and chloride penetration depth were decreased when the painting materials were applied in 28 days of wet curing. Additionally, for painting materials, with the order of ERCO, RCO, ERCO+WR, and WR, the carbonation and chloride penentration was delayed. Hence it is considered that ERCO shows the most favorable performance of resistance against carbonation and chloride penetration.

A Study of the Effect of Mineral Admixtures on the Chloride Diffusion of the Concrete Immersed in Chloride Solution (무기질 혼화재가 염수침지한 콘크리트의 염화물 확산에 미치는 영향에 관한 연구)

  • Kim Dong-Seok;Yoo Jae-Kang;Park Sang-Joon;Won Cheol;Kim Young-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.679-686
    • /
    • 2005
  • The corrosion of reinforcement induced by chloride ingress is the main deterioration cause of coastal reinforced concrete structures. In this paper, an experimental study was executed to investigate the effect of the kinds and replacement ratios of mineral admixtures (fly-ash, ground granulated blast-furnace slag silica fume and meta-kaolin), W/B and curing time on chloride diffusion of concrete by long-time immersion test in chloride solution. According to the result, the use of mineral admixtures was effective in improving the resistant to chloride ingress. The chloride penetration depth and diffusion coefficient were decreased as replacement ratios of mineral admixture were increased. The kind and replacement ratio of the mineral admixture are more important than the W/B in reducing the chloride diffusion of concrete. Chloride binding capacity of mineral admixture, which was sequenced in the order of MK

Characteristics of OCP of Reinforced Concrete Using Socket-type Electrodes during Periodic Salt Damage Test (주기적 염해 시험에 따른 소켓 타입 전극을 활용한 철근 콘크리트의 OCP 특성)

  • Lee, Sang-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.28-36
    • /
    • 2021
  • It is known that buried rebars inside concrete structures are protected from corrosion due to passive layer. It is very important to delay the timing of corrosion or evaluate a detection of corrosion initiation for the purpose of cost-beneficiary service life of a structure. In this study, corrosion monitoring was performed on concrete specimens considering 3 levels of cover depth(60 mm, 45 mm, and 30 mm), W/C(water to cement) ratio(40.0%, 50.0%, and 60.0%) and chloride concentration(0.0%, 3.5%, and 7.0%). OCP(Open Circuit Potential) was measured using agar-based socket type sensors. The OCP measurement showed the consistent behavior where the potential was reduced in wet conditions and it was partially recovered in dry conditions. In the case of 30 mm of cover depth for most W/C ratio cases, the lowest OCP value was measured and rapid OCP recovery was evaluated in increasing cover depth from 30 mm to 45 mm, since cover depth was an effective protection against chloride ion ingress. As the chloride concentration increased, the effect on the cover depth tended to be more dominant than the that of W/C ratio. After additional monitoring and physical evaluation of chloride concentration after specimen dismantling, the proposed system can be improved with increasing reliability of the corrosion monitoring.

CO2 Evaluation of Reinforced Concrete Column Exposed to Chloride Attack Considering Repair Timing (보수시기를 고려한 염해에 노출된 콘크리트 교각의 탄소량 평가)

  • Kim, Seong-Jun;Kim, Young-Joon;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • In this paper, $CO_2$ amount is evaluated considering repairing timing and unit $CO_2$ amount per repair method including various stage of material manufacturing, moving, and construction. Four mix proportions with mineral admixture are considered and repairing timing/numbers are simulated based on the results from Life 365 which can handle chloride penetration. Furthermore two repair methods (simple cover concrete replacement and replacement with electro-chemical method for removing chloride content) are considered and the related $CO_2$ emissions are evaluated. From the study, the case with high W/B (water to binder ratio) ratio shows smaller $CO_2$ emission in construction stage but it increases more rapidly with increasing number of repair. $CO_2$ emission considering electro-chemical method greatly increases with the increasing unit $CO_2$ for the repairing method. The numbers of jumping step (repairing number) are evaluated to be 9 for WB37-OPC, 18 for WB50-OPC, 4 for WB40-SG, and 7 for WB47-SG respectively. RC structures with the longer maintenance free period are evaluated to be advantageous for saving $CO_2$ emission.

Resistance to Corrosion of Reinforcing Steel and Critical Chloride Content of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 저항성 및 임계 염화물량)

  • Lee, Hyun-Jin;Bae, Su-Ho;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.375-381
    • /
    • 2017
  • Recently, due to the increasing of interest about the eco-friendly concrete, it is being increased to use concretes containing by-products of industry such as fly ash, ground granulated blast furnace slag, silica fume, and etc. Especially, these are well known for improving the resistance to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance to corrosion of reinforcement and critical chloride content of high volume fly ash concrete(HVFAC) which is replaced with fly ash for approximately 50% cement content. For this purpose, corrosion monitoring of reinforcement by half cell potential method was carried out for the cylindrical test specimens that the upper of reinforcement in concrete was exposed to detect the time of corrosion initiation for reinforcement. It was observed from the test result that the the time of corrosion initiation for reinforcement of HVFAC by the accelerated corrosion tests increased 1.2~1.3 times than plain concrete and the critical chloride contents of plain concrete and HVFAC were found to range $0.80{\sim}1.20kg/m^3$, $0.89{\sim}1.60kg/m^3$, respectively.

A Study on the Temporal Correlation of Long-term Exposure Test and Accelerated Corrosion Test of Rebar (장기폭로 시험과 철근 부식 촉진시험의 시간적 상관성에 관한 연구)

  • Lee, Min-Woo;Park, Sang-Soon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • Recent interest in the increased structural performance and durability evaluation of this concrete structure in a salt damage environment is increasing. The most secure and reliable method of accelerated corrosion test is a method to carry out the rebar corrosion monitoring can be exposed directly to the marine test site exposure. However, long-term exposure testinghas the disadvantage that a long period is necessary. So, a lot of research on RC of salt damage environment have beenpromoted as alternatives to replace this. However, accelerated corrosion test, in the short term only is appropriate and is but an accelerated test method to evaluate the critical chlorine concentration, there is a difficult problem that you still get the answer. It is one of the correlation problems accelerated test correspond to a certain period of exposure environment. Therefore, in this study, to clarify the differences rebar corrosion beginning, through the actual corrosion accelerated test in corrosion time and laboratory test chamber of the structure of the marine environment results in both environments, it is an object of correlation coefficient derived.