• Title/Summary/Keyword: 염소이온확산

Search Result 158, Processing Time 0.033 seconds

Analysis of Chloride Ion Penetraion for Marine Concrete Structure with Cyclic Humidity Environment (건습이 반복되는 환경하의 해양콘크리트 구조물에 대한 염소이온 침투 해석)

  • Han, Sang-Hun
    • Ocean and Polar Research
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • The diffusion model, which considers diffusion and sorption, is proposed. The FEM program developed on the basis of the diffusion model provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

Diffusion of Chloride Ions and Evaluation of Lifetime in Highway Bridges (고속도로 교량의 염소이온확산 특성과 공용수명 평가)

  • Shin Jae In;Park Chang Ho;Lee Byeong Ju;Lim Hong Beam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.663-666
    • /
    • 2005
  • Chloride attach is one of the main factors which cause the deterioration of structures. In the case highway bridges, de-icer salts very significantly increase the surface scaling due to frost action. The deteriorated concrete is subject to experience degrading of durability under chloride attach environment. In this study, diagnosis report of 147 bridges is investigated and core sample of 21 bridge decks is examined and analyzed. The results show that the cover of decks concrete is required more than 8cm for retaining bridge lifetime over 30 years.

  • PDF

Comparisons of Grain Size Analysis Results by Different Pretreatments Procedures in Loess-paleosol Sediments (뢰스-고토양 퇴적물의 전처리 과정에 따른 입도분석 결과 비교)

  • Yoon, Soon-Ock;Park, Chung-Sun;Hwang, Sang-Ill
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.5
    • /
    • pp.553-572
    • /
    • 2010
  • Grain size analysis of sediments and soils has been regarded as a one of the most important analytical methods in Earth Sciences. The results of grain size analysis by 10 different pretreatment procedures in loess-paleosol sediments are compared in the study. In spite of the most powerful effectiveness of dispersant(sodium hexametaphosphate) on the dispersions of sediments, the effects show large differences by its treatment orders with HCl. It may result from that $Na^+$ ions in the dispersant may not be able to effectively substitute $Ca^{2+}$ ions in the sediments due to the electrostatic forces between $Na^+$ and $Cl^-$ ions in the dispersant and HCl, respectively. Although $H_2O_2$ and HCl are more effective in dispersion than hot water, they do not affect greatly the dispersions. Therefore, the reliable results of grain size analysis can be obtained by selecting the adequate pretreatment procedures most suitable for the purposes of researches and characteristics of sediments.

A Study on Corrosion Resistance of the Reinforement in Concrete Using Blast-Furnace Slag Powder (고로슬래그미분말을 사용한 콘크리트의 염화물이온에 의한 철근부식 저항성 연구)

  • Kim Eun-Kyun;Kim Jin-Keun;Lee Dong-Hyuk;Kim Young-Ung;Kim Yong-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.1-9
    • /
    • 2004
  • This paper represents the permeability of chloride ions and the corrosion performance in the concrete blended with granulate blast furnace slag exposed to chloride environment. An ordinary cement (type I ) and sulfate resisting cement(type V) were used for the experiment. The two cements were combined with $0\%$, $25 \%$, $40\%$, and $55\%$ of the granulated blast furnace slag. The accelerated permeability tests of chloride ions were performed in accordance with ASTM C1202, and the accelerated corrosion tests of steel were carried out by using the method of immersion/drying cycles. After water curing 28 days, 56 days and 91 days, these tests were conducted until 30 cycles. In every cycle, test specimens were wetted in $3\%$ NaCl solution for three days and dried again in $60^{\circ}C$ air for four days. As an experimental results, the diffusion coefficient of chloride ions of the ordinary cement Concrete Combined granulated blast furnace slag was much lower than that of non granulated blast furnace slag concrete. Moreover, the diffusion coefficient of chloride ions of sulfate resisting cement concrete was higher than that of ordinary cement concrete. On the basis of the results of accelerated corrosion tests, corrosion resistance of the concrete mixed with granulated blast furnace slag shows good to corrosion resistance, however, the concrete with sulfate resisting cement shows bad to corrosion resistance.

Correlation of Soil Particle Distribution and Hydrodynamic Dispersion Mechanism in Ununiformed Soils Through Laboratory Column Tests (실내주상실험에 의한 불균일한 토양의 입도와 수리분산기작의 상관성 연구)

  • Kang, Dong-Hwan;Chung, Sang-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.28-34
    • /
    • 2006
  • Laboratory column tests using $Cl^-$ tracer were conducted to study the correlation of soil particle distribution and hydrodynamic dispersion mechanism with three kinds of ununiformed soil samples, in which the ratio of gravel and sand versus silt and clay is 24.5 for S-1 soil, 4.48 for S-2 soil, and 0.4 for S-3 soil. Chloride breakthrough curves with time were fitted with gaussian functions. The relative concentrations of chloride were converged to 1.0 after 0.7 hours for S-1, 6.3 hours for S-2, and 389 hours for S-3. Average linear velocity, longitudinal dispersion coefficient, and longitudinal dispersivity were calculated by chloride breakthrough curves. Longitudinal dispersion coefficients were $1.20{\times}10^{-4}\;m^2/sec$ for S-1, $8.87{\times}10^{-7}\;m^2/sec$ for S-2, and $1.94{\times}10^{-9}\;m^2/sec$ for S-3. Peclet numbers calculated by the molecular diffusion coefficient of chloride and the mean grain diameters of soils were $2.59{\times}10^2$ for S-1, $6.27{\times}10^0$ for S-2, and $1.35{\times}10^{-4}$ for S-3. Mechanical dispersion was dominant for the hydrodynamic dispersion mechanism of S-1. Both mechanical dispersion and molecular diffusion were dominant for the hydrodynamic dispersion mechanism of S-2, but mechanical dispersion was ascendant over molecular diffusion. Hydrodynamic dispersion in S-3 was occurred mainly by molecular diffusion. When plotting three soils on the graph of $D_L/D_m$ versus Peclet number produced by Bijeljic and Blunt (2006), the values of $D_L/D_m$ for S-1 and S-2 were more than 2.0 order compared to their graph. S-3 was not plotted on their graph because the Peclet number was as small as $1.35{\times}10^{-4}$.

Probability-Based Durability Analysis of Concrete Structures under Chloride Attack Environments (염해를 받는 콘크리트 구조물의 확률론적 내구성 해석)

  • Kim, Jee-Sang;Jung, Sang-Hwa;Kim, Joo-Hyung;Lee, Kwang-Myong;Bae, Su-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.239-248
    • /
    • 2006
  • Recently, a variety of researches has been carried out to obtain a more controlled durability and long-term performance of concrete structures under chloride attack environments. In particular, new procedures for probability-based durability analysis/design have been noticed to be very valuable for the enhancement of service life of concrete structures. Although there is still a lack of relevant data, this approach has been successfully applied to some new concrete structures. In this paper, the diffusion equation based on Fick's second law has been solved with a time dependent diffusion coefficient and the probabilistic analysis of the durability performance has been carried out by using a Monte Carlo Simulation. From the results, the influence of each parameter on the durability of concrete structures was investigated and the new procedure for durability analysis was demonstrated in terms of chloride penetration data from various concrete structures. The new procedure might be very useful in designing important concrete structures and help to predict the remaining service life of existing concrete structures under chloride attack environments.

Estimation of Distributed Groundwater Recharge in Mihocheon Watershed (미호천 유역의 분포형 지하수 함양량 산정)

  • Chung, Il-Moon;Kim, Nam-Won;Lee, Jeong-Woo;Won, Yoo-Seung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.698-701
    • /
    • 2007
  • 지하수 개발가능량 산정을 위한 함양량의 평가는 수문계의 물리적인 형태나 함수층의 수리성 분석 및 수직인 지질분포를 파악하여 어떤 조건하에서 물이 유입 유출되는가를 파악한 후에만 가능하다. 또한 지하수계의 물리적인 형태를 이해함으로써 조사지역의 지표수계나 지하수계의 양계를 통해서 흐르는 물의 양을 결정짓는 물수지 분석이 수행되어야 한다. 이에 따라 강수량, 증발산량, 지하수 유출량, 지표유출량 그리고 하천유출량 등을 수문학적으로 고려해야만 한다. 본 연구는 지표수-지하수 결합모형을 도입하여 분포형 지하수 함양량의 시공간적인 변동성을 파악하는 데 그 목적이 있다. 이를 위해 지표수-지하수 결합모형인 SWAT-K모형을 미호천 유역에 적용하였으며, 지표수의 총유출량과 지하수위의 공간분포자료를 이용하여 검정과 검증을 수행하였다. 전체유역에 대한 연평균 함양량은 수문총량의 약 19%인 것으로 나타났다. 1999년${\sim}$2004년까지의 소유역별 연간 함양량 결과를 월별로 나타냈으며, HRU(Hydrologic Response Unit)별 함양량의 공간분포를 통해 월별, 계절별 특성을 살펴볼 수 있었다. 소유역 모두 강수가 집중하는 7-9월에 걸쳐 많은 함양이 이루어지며 $1{\sim}3$월에는 상대적으로 함양이 적은 것을 볼 수 있다. 월함양량의 경우 최대 약200mm범위내에서 유역의 토지이용 및 토양특성, 경사등에 따라 매우 비균질하게 분포하는 것을 확인할 수 있었다. 이와같은 함양량의 시공간적 불균일성으로 인해 지하수 관리방안은 소유역별 함양특성을 반영해야 할 것으로 판단된다.의 종분산지수가 일반적인 자연대수층에 비해 9.1배 정도 높다는 것을 의미한다. 이는 시험대수층의 투수성이 매우 높아 염소이온의 용질이송이 매우 빠르게 발생되었기 때문이다. 본 연구에서 추정된 종분산지수를 Gelhar et al.(1992)의 연구 결과와 비교 분석한 결과에서도 시험규모에 비해 매우 높은 수리분산이 발생된 것으로 나타났다. 그리고 염소이온의 확산면적을 추정하기 위해, 수렴흐름 추적자시험에 의한 종분산지수와 시험대수층의 평균선형유속을 이용하여 종분산계수를 구하였다. 현장에서 수행된 양수시험에 의한 평균선형유속 22.44 m/day와 평균 종분산지수 0.4155 m를 적용하여 산정된 종분산계수는 $9.32\;m^2/day$이었다. 따라서, 시험부지 내 충적층에서 일정한 양수율$(2,500\;m^3/day)$로 지하수를 개발할 시에 양수정 주변지역으로 유입되는 염소이온의 확산면적은 1일 $9.32\;m^2$ 정도일 것으로 나타났다.적인 $OH{\cdot}$ 의 생성은 ascorbate가 조직손상에 관여할 가능성을 시사하였다.었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin

  • PDF

Diffusion of Cr(VI) in Porous Media (심층 지하에서의 육가 크롬 확산)

  • 현재혁
    • The Journal of Engineering Geology
    • /
    • v.3 no.2
    • /
    • pp.203-214
    • /
    • 1993
  • Underground Injection Control regulations for Class I injection wells require that the vertical dufusion be considered as a mechanism for transport of contaninants in evaluating containment Due to the low permeability in the confining aquitard, the movement of contaminants over the long term is controlled by the molecular diffusion. The movement can be predicted, using the Fick' S second law of diffusion. The diffusion coefficient in Fick' s law has been determined experimentally in this study. Instantaneous injection of $^{51}Cr$ was used to trace the distribution of Cr(VI) in soil plugs and an analytical solution was applied to calculate the diffusion coefficients. This study shows the effect of environmental factors, such as temperature, chloride concentration, applied amount of $^{51}Cr$, and bulk density of injection formations on diffusion of Cr(VI)

  • PDF

Development and Application of Unit Table Form using Euro Form for High-rise Building Construction (슬래그 혼입 콘크리트의 염소이온 차단성능)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.136-137
    • /
    • 2018
  • The properties of concrete produced by ready mixed concrete company in Busan were measured. Because the concrete was mixed with blast furnace slag and fly ash etc., the compressive, tensile strength and chloride ion diffusion coefficient were lower than OPC concrete even though the specified concrete strength was same. If the durability about salt attack were satisfied, the concrete of lower specified concrete strength would be adopted to concrete mixing design. FEM analysis was carried out to predict the life time expectancy.

  • PDF

Experimental Study on Diffusivity of High Performance Concrete containing GGBF for Road Structures (고로슬래그 미분말 혼합 도로구조물용 고성능 콘크리트의 확산특성에 대한 실험적 고찰)

  • Han, Seoung-Woo;Kim, Hong-Sam;Kim, Jin-Cheol;Ahn, Tae-Ho;Ahn, Tae-Song
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.195-196
    • /
    • 2010
  • The objective of this experiments is to investigate chloride diffusivity of high performance concrete based binary cimentitious materials such as ordinary portland cement and ground granulated blast furnace slag. The results from the study will be utilized as the basic data and guideline in making standard mixproportions and the manufacture, construction work and quality control of HPC.

  • PDF