• Title/Summary/Keyword: 염분침투

Search Result 117, Processing Time 0.022 seconds

Chloride Penetration Analysis of Concrete Structures with Chloride Concentration (염분 농도에 따른 콘크리트 구조물의 염분침투 해석)

  • Yang, Joo-Kyoung
    • Journal of the Korea Computer Industry Society
    • /
    • v.9 no.3
    • /
    • pp.137-142
    • /
    • 2008
  • The major influence factor on chloride penetration into concrete structures is chloride ion concentration. In this study, chloride penetration analyses with chloride ion concentration were carried out by the developed program. Also, the service life of concrete structures was predicted. The penetration depth was 32mm in case that chloride ion concentration wad 600ppm. It was shown that the service life of concrete structures with 40mm cover depth was 167 years even though they had been exposed at chloride ion concentration 600ppm during 100 years.

  • PDF

Chloride Penetration of Concrete Mixed with High Volume Fly Ash and Blast Furnace Slag (FA 및 BFS를 다량 혼입한 콘크리트의 염분침투성)

  • Park, Ki-Cheul;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • This study examined dynamic and characteristics and chloride penetration of concrete mixed with large amount of FA and BFS, which are considered for positive application to construction fields with purpose of long-tern durability of concrete structures. As a result of strength test on FA and BFS, FA concrete showed higher increase of strength compared to OPC, when FA4000 and FA5000 were mixed 30%, respectively. For BFS concrete, those mixed with 30% and 50% of BFS8000, respectively, showed higher or equivalent strength compare to OPC. As a result of test of chloride penetration on FA and BFS, diffusion coefficients of concrete mixed with 30% FA4000 and FA5000, respectively, showed to restrain average 6.5% of diffusion coefficient compared to OPC. And in case of BFS concrete, those mixed with BFS6000 and BFS8000, restrained diffusion of chloride ions 253% and 336%, respectively, compared to OPC. Therefore, Mixing 50% of BFS was most efficient in order to maximize restraint of chloride penetration according to metathesis of large amount. For relation between compression strength and diffusion coefficient of FA and BFS concrete, as strength increased, diffusion coefficient decreased. In this study, when mixing FA and BFS to concrete for long-run durability and restraint against chloride penetration, for FA, mixing it to concrete with less or equivalent 30% of replacement rate was most efficient. And for BFS, as fineness was higher and mixing it to concrete with less or equivalent 50% of replacement rate, there were results of higher strength compared to OPC and more efficient restraint of chloride ions.

The Analysis of Chloride Ion Penetration into a Concrete Structure in Marine Environment (해안환경하에 있는 콘크리트의 염분침투해석)

  • Cho, Sun-Kyu;Jeon, Gui;Shin, Chee-Burm
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.3 s.29
    • /
    • pp.68-74
    • /
    • 1998
  • An increase of concrete construction in marine environments as well as an increasing use of marine aggregate at the mixing stage of concrete has provoked an important problem. A high concentration of chloride ion in the vicinity of steel bars in concrete is the principal cause of premature reinforcement corrosion in concrete structures. In this study, the behavior of chloride ions introduced into concrete from concrete surface by marine evironment was analysed. A mathematical model including the diffusion of chloride ion in aqueous phase of pores, the adsorption and desorption of chloride ions to and from the surface of solid phase of concrete and the chemical reactions of chloride ions with solid phase was presented. Finite element method was employed to carry out numerical analysis. The results of this study may be used to predict the onset of reinforcement corrosion and to identify the maximum limit of chloride ions contained in concrete admixtures.

  • PDF

A Study on the Characteristics of the Seawater Seepage According to Stratum Structures (지층구조에 따른 해수 침투 특성 분석)

  • Ahn, Seung-Seop;Park, Dong-Il;Jung, Do-Joon;Moon, Sang-Cheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1982-1985
    • /
    • 2010
  • 해수침투는 대수층의 염분 농도를 증가시켜 지하수 염분화에 의한 용수의 부족 등을 야기시키며 다른 지하수 오염과 마찬가지로 회복에 대한 막대한 비용과 시간이 소모되어 피해지역에 대한 정확한 현황파악이 어려워 피해방지대책의 수립이 필요한 실정이다. 따라서 본 연구에서는 흐름과 이송을 모의할 수 있는 GMS-FEMWATER 모델을 이용하여 대상지역의 지층구조를 구분하고 실제 대상지역의 지층과 동일하게 모델링하여 해안지역의 해수침투에 대한 특성을 규명하였다. 분석결과 양수기간이 길어 질수록 지하수두강하 폭이 양수기간 30일, 60일, 90일 및 180일 경과 시 초기 수위에서 점차 4.25m (1.36%), 3.5m (1.13%), 2.96m (0.97%), 1.97m (0.65%)으로 감소하는 것을 알 수 있었다. 또한 양수량이 많은 관정일수록 해수 침투가 큰 것을 알 수 있다. 양수기간 30일 0.59mg/l, 채수 60일 1.65mg/l, 채수 90일 3.14mg/l, 180일 5.55mg/l으로 분석되었다. 이결과로 볼 때 양수기간 초기에서 기간이 지날 수록 해수침투가 큰영향을 주는 것을 알 수 있었다.

  • PDF

Effect of Compressive Loading on the Chloride Penetration of Concrete Mixed with Granulated Blast Furnace Slag (고로슬래그미분말을 혼입한 콘크리트의 염분침투성에 미치는 압축하중의 영향)

  • Kim, Dong-Hun;Lim, Nam-Gi;Horiguchi, Takashi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.6
    • /
    • pp.71-78
    • /
    • 2009
  • The analysis of the effect of loading on chloride penetration into concrete is very important. In this study, we confirmed that the chloride penetration rates for plain and BFS concrete were increased by 47% and 89% under compressive stress, respectively. The diffusion coefficient of BFS concrete was lower than for conventional concrete with no BFS, no loads, and under stressed states. Therefore, BFS substitution plays an important role in the repression of chloride penetration even under compressive stress. Under compressive stress,the diffusion coefficient for BFS concrete was higher with increasing stress, and this was also the case for plain concrete. However, BFS concrete was strongly influenced by compressive stress in comparison to plain concrete. We investigated the effect of the difference of specific surfaces on the diffusion coefficient. As a result, the larger specific surface of BFS exhibited a lower diffusion coefficient. This tendency was most pronounced under the high stress conditions.

Effects of the Pumping Rate on the Salt Concentration (지하수의 염분농도 변화에 미치는 양수의 영향)

  • Park, Jae-Sung;Lee, Ho-Jin;Kim, Kyoung-Ho;Yun, Young-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1895-1899
    • /
    • 2006
  • Seawater intrusion phenomenons of coastal area happen by natural or artificial factor. For example, density difference of seawater and fresh water, surface of the water change by tidal current, pumping, aggregate picking from mouth of a river, large scale reclamation in water area business etc. This research analyzed effect that groundwater TDS changed by pumping.As a result, it was expose that TDS density increases by sudden inflow of seawater when do pumping up more than $200m^3/day$. Finally, We are expected to prevent calamity by seawater intrusion in coastal area through this study and propose optimum pumping amount to use groundwater safety.

  • PDF

Analysis of Chloride Ion Penetration Properties into Concrete on Road Facilities Depending on the Deterioration Environments (국도 상 도로시설물 대상 열화환경 조건 별 콘크리트 염화물 침투 특성 분석)

  • Min, Jiyoung;Lee, Jong-Suk;Lee, Tack-gon;Cha, Ki-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.102-113
    • /
    • 2021
  • The deterioration environments caused by de-icing salt and airborne chlorides in the seashore, evaluated in the "Detailed guideline for safety and management practice of facilities (performance evaluation)", were reviewed in terms of penetrated chlorides into concrete on various road facilities. Target concrete structures, in this study, were 4 concrete barriers in Gangwon area, 3 concrete barriers and 1 retaining wall in Busan area, and 4 bridges in Gangwon-do, Seoul, Gyeonggi-do, and Busan. The deterioration environments were classified into three categories: direct and indirect de-icing salt attack, and airborne salt attack depending on the distance to seashore and the height of pier, and the penetrated chlorides in to concrete were analyzed. The results showed that (1) the regional deterioration environments were clearly classified by de-icing salt sprayed days (snowfall days), (2) the penetrated chlorides increased significantly when leakage occurred through slabs or expansion joints, and (3) the airborne chlorides affected to a height of 20 m concrete in the seashore, Busan. From these, it could be confirmed that the chloride ion penetration properties depend on the exposed aging environment, member location and height, and deterioration status, even on the same structure, so the selection of target members and location is very important in the inspection and maintenance. If the database of penetrated chlorides properties in various deterioration environments is constructed, it is expected that the proactive durability management on concrete structures will be possible in the field.

Chloride Penetration Resistance and Flexural Behavior of Hybrid Organic Fibers Reinforced Concrete (유기계 섬유로 하이브리드 보강된 콘크리트의 휨 거동 및 염분침투저항성)

  • Kim, Seung Hyun;Kang, Min Bum;Lee, Dong Wook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.105-115
    • /
    • 2015
  • In this study, to understand mechanical characteristic of hybrid reinforced concrete by PVA-fiber 6 mm and PP-fiber 50 mm, which are organic fiber replaced macro-fiber with PP-fiber, four mixed Hybrid Organic Fibers Reinforced Concrete (HFRC) is compared with one mixed plain concrete without fiber reinforcement. Volume portion of the fibers are limited under one percent. The result presents that hybrid reinforcement of the organic fibers cannot maximize stiffness and ductility behavior of the steel fiber reinforcement. however, in comparison to plain concrete, it is confirmed that meaningful relation between toughness index and equivalent flexural strength with advanced ductility behavior. Also, in the case of concrete hybrid reinforced by organic fiber, when the volume portion of the fiber increases, ductility also increases. PP-fiber, which is macro fiber, has more effect on the flexural behavior of concrete than PVA-fiber, which is micro fiber, does. The result also shows that it decrease chloride penetration in chloride penetration test.