• Title/Summary/Keyword: 염료 가시화

Search Result 14, Processing Time 0.024 seconds

Analysis of Flow Visualization Results Using Fourier Transform (퓨리에 변환을 활용한 유동 가시화 비교 분석)

  • Koo, Bon-guk;Park, Jun-mo;Kang, Yong-Duck
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.199-204
    • /
    • 2019
  • In the boundary layer, vortical system has been analyzed by the statistical methods to identify the vortex interaction. However, there are the limitations in explaining vortices by the mean velocity or the standard deviation. This paper proposed a method to establish a frequency analysis by Fourier transform in order to simultaneously investigate various scale vortices. For this purpose, the flow visualization conducted to reveal a standing vortex, a hairpin vortex and a wake region around a hemisphere attached on a flat plate in a water channel. In addition, the velocity where the hairpin vortex was being generated in the wake region was measured by a hot-film anemometer. To observe changes in the vortex interaction, suction was applied through a hole in front of the hemisphere. For the evaluation of the proposed frequency analysis, the existing statistical results were compared to the frequency analysis that corresponds to the qualitative results of the flow visualization.

Flow Changes by Stent Insertion in Fusiform Aneurysm Models (스텐트 삽입에 의한 방추형 동맥류 내부 유동의 변화)

  • 이계한;서남현
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.535-542
    • /
    • 2001
  • Endovascular embolization technique using a steno is currently used to treat the wide neck aneurysm. Since intraaneurysmal flow characteristics affect thrombus formation and embolisation process. flow visualization technique incorporating photochromic dye was used to elucidate hemodynamic changes by stenting Inside the fusiform aneurysm models. Qualitative observation of flow field and measurement of wall shear rates were Performed at five aneurysm wall locations under pulsatile flow. Intraaneurysmal flow motion was reduced and sluggish vortical motion was maintained during late deceleration phase by stenting. Also wall shear rates were reduced and OSI's were increased in the stented model. These flow characteristics Provide hemodynamic environment favorable for thrombus formation and intimal hyperplasia. The results of this study show hemodynamic changes by stenting Promote thrombus formation and aneurysm embolisation.

  • PDF

Skin-Friction Drag Reduction in Wake Region by Suction Control on Horseshoe Vortex in front of Hemisphere (반구 전방에 생성된 말굽와류 흡입제어에 의한 후류영역 마찰저항 감소에 관한 연구)

  • Koo, Bonguk;Kang, Yong-Duck
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.795-801
    • /
    • 2019
  • The aim of this study was to investigate the possibility of the skin-friction reduction by vortex control. A vortical system such as a horseshoe vortex, a hairpin vortex, and a wake region was induced around a hemisphere attached on a Perspex flat plate in the circulating water channel. Hairpin vortices were developed from the wake region and horseshoe vortices were formed by an adverse pressure gradient in front of the hemisphere. The horseshoe vortices located on the flank of the hemisphere induced a high momentum flow in the wake region by the direction of their vorticity. This process increased the frequency of the hairpin vortices as well as the frictional drag on the surface of the wake region. To reduce the skin-friction drag, suction control in front of the hemisphere was applied through a hole. Flow visualization was performed to optimize the free-stream velocity, size of the hemisphere, and size of the suction hole. Once the wall suction control mitigated the strength of the horseshoe vortex, the energy supplied to the wake region was reduced, causing the frequency of the hairpin vortex generation to decrease by 36.4 %. In addition, the change in the skin-friction drag, which was measured with a dynamometer connected to a plate in the wake region, also decreased by 2.3 %.

Flow Lab. : Flow Visualization and Simulation (핵종이동 가시적 현상관찰및 수치모사)

  • Park Chung-Kyun;Cho Won-Jin;Hahn Pi1-Soo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.134-142
    • /
    • 2005
  • The experimental setups for flow visualization and processes identification in laboratory scale (so cal led Flow Lab.) has developed to get ideas and answer fundamental questions of flow and migration in geologic media. The setup was made of a granite block of $50{\times}50cm$ scale and a transparent acrylate plate. The tracers used in this experiments were tritiated water, anions, and sorbing cations as well as an organic dye, eosine, to visualize migration paths. The migration plumes were taken with a digital camera as a function of time and stored as digital images. A migration model was also developed to describe and identify the transport processes. Computer simulation was carried out not only for the hydraulic behavior such as distributions of pressure and flow vectors in the fracture but also for the migration plume and the elution curves.

  • PDF