• Title/Summary/Keyword: 열-유동해석

Search Result 933, Processing Time 0.032 seconds

Preliminary Thermal-Hydraulic Analysis of the CANDU Reactor Moderator Tank using the CUPID Code (CUPID 코드를 이용한 CANDU 원자로 칼란드리아 탱크 내부유동 열수력 예비 해석)

  • Choi, Su Ryong;Lee, Jae Ryong;Kim, Hyoung Tae;Yoon, Han Young;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.95-105
    • /
    • 2014
  • The CUPID code has been developed for a transient, three-dimensional, two-phase flow analysis at a component scale. It has been validated against a wide range of two-phase flow experiments. Especially, to assess its applicability to single- and two-phase flow analyses in the Calandria vessel of a CANDU nuclear reactor, it was validated using the experimental data of the 1/4-scaled facility of a Calandria vessel at the STERN laboratory. In this study, a preliminary thermal-hydraulic analysis of the CANDU reactor moderator tank using the CUPID code is carried out, which is based on the results of the previous studies. The complicated internal structure of the Calandria vessel and the inlet nozzle was modeled in a simplified manner by using a porous media approach. One of the most important factors in the analysis was found to be the modeling of the tank inlet nozzle. A calculation with a simple inlet nozzle modeling resulted in thermal stratification by buoyance, leading to a boiling from the top of the Calandria tank. This is not realistic at all and may occur due to the lack of inlet flow momentum. To improve this, a new nozzle modeling was used, which can preserve both mass flow and momentum flow at the inlet nozzle. This resulted in a realistic temperature distribution in the tank. In conclusion, it was shown that the CUPID code is applicable to thermal-hydraulic analysis of the CANDU reactor moderator tank using the cost-effective porous media approach and that the inlet nozzle modeling is very important for the flow analysis in the tank.

A Numerical Study on the Heat and Fluid Flow in Steam Reforming Reactor (수증기 개질 반응로에 대한 열유동 해석)

  • Han, Jeongok;Lee, Joongseong;Lee, Yeongcheol;Hong, Seongho;Hong, Sungkook;Dong, Sangkeun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.78-84
    • /
    • 2013
  • A numerical study on the heat and fluid flow has carried out for the design of the steam reforming reactor which consists of six reforming tubes and one burner. Reforming reaction calculation is coupled with the heat and fluid flow one. The burner type in the reforming reactor is chosen through the fluid flow calculation according to different type of burner structure. It is shown that the significant temperature gradient exists in the reforming reactor, affecting the component variation along the length of reforming tube. The component ratio of reforming gas is changed by the variation of SCR and GHSV.

Numerical Analysis of Natural Convection inside Spray Coating Room on Temperature Distributions (자연대류를 고려한 스프레이 코팅 룸에서의 온도분포 해석)

  • Kim, Nam Woong;Kim, Bo-Seon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.425-430
    • /
    • 2019
  • Zinc coatings are widely used because of their environmental friendliness and high performance. In general, the coating temperature is a major factor in determining the coating layer thickness and coating quality. In the case of a zinc coating, a uniform and appropriate coating temperature is required. In this study, a thermal flow simulation of the air flow was performed to analyze the temperature distribution of a zinc spray coating room in a natural convection state. Using SolidWorks, modeling was performed for two spray coating rooms, a preheating room, and a drying room, and a thermal flow coupled analysis was performed using ANSYS-FLUENT. As a result of the analysis, the temperature distribution characteristics in the spray coating rooms were determined. It was found that the present temperature was below the target temperature of $25^{\circ}C$. Simulations were conducted for two different boundary conditions (one with a heater added and another with the open part closed). The simulation results show that the method of closing the open part is better than adding the heater.

Development of Simulation for Vuilleumier Cycle Heat Pump (VM 사이클 히트펌프 설계프로그램의 개발)

  • 박병덕;이기우
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.105-113
    • /
    • 2001
  • 지구환경문제와 에너지문제를 해소하는 한 방법으로서 Vuilleumier 사이클 기관(VM)을 이용한 공조기형 열구동형 히트펌프시스템(VMHP)이 각광을 받고 있다. VMHP의 제작에 있어서는 VM의 각 부분의 이론적 검토 및 최적설계를 위한 해석프로그램의 개발이 필수적이고 최적설계를 위한 설계 기본서의 도출 및 설계자료의 확보가 필요하다. VMHP의 상세한 성능해석이나 설계에 활용 가능한 성능해석프로그램을 개발하였다. 해석은 VM의 시스템의 각 부분을 11개 부분으로 나누어 단열모델해석으로 수행하였다. 열교환기에서의 열전달 성능과 재생기손실, 열전도손실, 셔틀손실, 유동에 의한 압력손실과 열압축측과 열펌프측 사이의 마찰손실, 피스턴실 및 로드실의 마찰손실을 고려한 해석을 수행하였다. 해석에 의한 계산치의 정확성을 본 해석결과를 이용하여 제작한 시험기에 의해 비교하였다. 계산치와 시험기에 의한 전체성능을 비교하였고 또한 각각의 손실에서 고유한 파라미터를 추출하여 그 파라미터의 변화에 따른 열손실 전체의 변화 정도를 파악하여 실험치와 계산치의 정상적인 비교로부터 성능해석의 정도를 비교하였다. 비교결과에 의해 난방능력은 8%, 냉방능력은 19%의 최대오차로서 본 해석결과가 VMHP의 설계를 위해 유용한 수단으로 사용될 수 있음을 확인하였다.

  • PDF

Porous Media Modelling and Verification of Thermal Analysis for Inlet and Outlet Ducts of Spent Fuel Storage Cask (사용후핵연료 저장용기 유로입출구의 다공성매질 모델링 및 열해석 검증평가)

  • Lee, Ju-Chan;Bang, Kyung-Sik;Choi, Woo-Seok;Seo, Ki-Seog;Ko, Sungho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.223-232
    • /
    • 2018
  • Bird screen meshes are installed at the air inlet and outlet ducts of spent fuel storage casks to inhibit the intrusion of debris from the external environment. The presence of these screens introduces an additional resistance to air flow through the ducts. In this study, a porous media model was developed to simplify the bird screen meshes. CFD analyses were used to derive and verify the flow resistance factors for the porous media model. Thermal analyses were carried out for concrete storage cask using the porous media model. Thermal tests were performed for concrete casks with bird screen meshes. The measured temperatures were compared with the analysis results for the porous model. The analysis results agreed well with the test results. The analysis temperatures were slightly higher than the test temperatures. Therefore, the reliability and conservatism of the analysis results for the porous model have been verified.

양극으로의 에너지 플럭스 유입을 고려한 대기압 아르곤 자유연소아크 해석

  • Lee, Won-Ho;Lee, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.498-498
    • /
    • 2012
  • 직류 아크 토치를 이용하여 열플라즈마를 발생시키는 방법은 전극의 구성에 따라 크게 비이송식(non-transferred)과 이송식(transferred)의 2가지 형태로 나눌 수 있다. 1950년대 H. Maecker 등에 의해 이론적 기초가 형성되기 시작한 이송식 아크 플라즈마 발생장치는 처리 대상물질을 전극으로 사용하여 양극에서의 에너지 전달을 직접 이용할 수 있으므로 열효율이 매우 높기 때문에 이를 이용한 고출력 토치에 관한 활발한 연구가 지속되고 있다. 본 연구에서는 대기압 아르곤 자유연소아크 방전에 의해 발생되는 열플라즈마의 열유동 특성을 수치적으로 해석하기 위하여 아크 기둥의 온도, 압력 및 속도 특성을 Navier-Stokes 방정식과 Maxwell 방정식을 연계 계산하였다. 또한 아크-전극 상호작용(arc-electrode interaction) 모델링을 통한 양극(anode)인 처리 대상물질로의 에너지 플럭스 유입을 고려하여 전극 내부의 온도분포를 계산하였다. 해석결과를 검증하기 위하여 음극과 양극 사이 플라즈마 기둥(column)의 중심축 온도는 Haddad & Farmer(1984)의 실험데이터와 비교하였고, 양극으로의 에너지 플럭스 및 온도분포 데이터는 Bini 등(2006)의 실험 및 해석데이터와 비교하여 만족스런 일치를 확인하였다.

  • PDF

Analysis of Mechanical Face Seals for Design Purpose. Part II : Thermoelastic, Wearing and Vibrational Effects (설계목적을 위한 기계평면시일의 해석. 제2보 : 열탄성, 마모 및 진동의 영향에 관하여)

  • Kim, Chung Kyun
    • Tribology and Lubricants
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 1991
  • 기계평면시일의 접촉 운동면에서 유체가 비압축성이고, 점성의 영향을 받는 경우에 대한 체적누설 유동량과 마찰 토오크를 멱급수의 방법을 이용하여 추정하였다. 본 연구에서 고려되고 있는 설계인자로 시일의 경사도, 접촉 운동면에서의 사인파형, 코우닝, 열탄성 변화량, 마모량, 시일의 스프링 강성도에 따른 축방햐의 변화량을 종합적으로 고려하여 해석하였다. 계산된 결과에 의하면 특히 회전속도가 증가되면 열탄성 변화량에 의한 시일의 누설 마찰 토오크가 커다란 영향을 받고 있는 것으로 나타나고 있다.

Numerical analysis on thermal-fluidic characteristics of the magnetic fluid in a cavity using GSMAC (GSMAC법을 이용한 밀폐된 정방형관내 자성유체의 열-유동 특성에 관한 해석적 연구)

  • Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.997-1002
    • /
    • 2013
  • The article is aiming to investigate the thermal-fluidic characteristics of magnetic fluid in a cavity using GSMAC (generalized-simplified marker and cell method). The transport equations of the magnetic fluid are including the continuity equation, momentum equation and energy equation for natural convection and Maxwell equation and magnetization equation of magnetite nano-sized particles motion. In addition, the heat transfer characteristics such as temperatures and Nusselt numbers and flow characteristics such as streamlines and isotherms of the magnetic fluid were analyzed with the intensity and direction of the magnetic fields. As a result, the thermal-fluidic characteristics of the magnetic fluid in a cavity were could be controlled by the intensity and direction of the magnetic fields.

Three-Dimensional Numerical Analysis of Arc Plasmas with an Axial Magnetic Field Vacuum Interrupter (축자계 진공차단부에서 발생하는 아크 플라즈마 3차원 수치해석)

  • Seo, Hyeon-Seok;Kim, Yun-Je;Lee, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.249-249
    • /
    • 2011
  • 전력용 개폐장치인 진공차단기의 차단부가 송배전 시스템에 30 [kA] 정도의 커다란 사고전류가 흐르는 것을 방지하기 위하여 동작될 때 차단부 내부 전극 사이에 25,000 [K] 이상의 아크 플라즈마가 발생하게 된다. 두 전극 사이에 발생된 아크 플라즈마는 약 10 ms~20 ms 동안 지속되다가 교류전원의 전류영점 부근에서 회복된 절연성능으로 인하여 자연스럽게 소멸되지만, 대전류 구간동안 아크 플라즈마의 집중 현상 등에 의하여 전극의 심각한 손상 등이 발생되면 절연성능이 요구된 만큼 회복되지 못하여 사고전류를 차단하지 못하며 시스템에 연결된 기기들에게 심각한 손상을 입히고 정전사고를 일으킨다. 본 연구에서는 전자계-열유동 연성해석기법을 이용한 축자계 진공차단부에서 발생하는 아크 플라즈마의 3차원 수치해석을 통하여 전극의 심각한 손상을 입히는 아크플라즈마의 집중 현상에 관한 축자계의 영향을 고찰하고자 한다. 수치해석을 위한 아크 영역은 양극과 음극의 직경과 같은 직경의 원기둥으로 가정하였고, 전자계 해석으로부터 얻어진 로렌츠 힘과 줄열을 열유동 해석을 위한 Navier-Stokes 방정식의 파라미터로 입력하여 해석을 수행함으로써 전자계와 유체역학적인 영역을 동시에 연계한 순차적 일방향 연성해석 기법을 적용하였다. 컵형 축자계 진공차단부 내 아크영역에서의 로렌츠 힘의 특성과 온도분포에 대하여 수치해석을 수행하였고, 크기가 다른 두 로렌츠 힘에 의하여 양극표면으로 집중되는 온도분포의 크기를 비교함으로써 진공아크 플라즈마의 집중현상에 영향을 미치는 주요 요소를 규명할 수 있었다.

  • PDF