• Title/Summary/Keyword: 열 펌프

Search Result 911, Processing Time 0.028 seconds

Performance Analysis of an Earth Coupled Heat Pump System Operated by an Engine(II) - Performance Analysis of a Vapour Compression type Compact Heat Pump - (엔진구동 지열 열펌프의 성능 분석(II) - 소형 증기압축식 열펌프의 성능 분석 -)

  • 김영복;송대빈;손재길
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.501-512
    • /
    • 1999
  • In this study, the coefficient of performance of a vapour compression heat pump system was analyzed for the evaluation of the heat pump performance. A water-to-air heat pump was assembled and tested by changing the level of the compressor driving speed and the air mass flow rate during air heating process. The coefficient of performance for air heating was 2.6~3.8 and that for water cooling was 1.0~1.4. The coefficient of performance was not depending on the levels of the compressor driving speed or levels of the air mass flow rate, but on the temperature of the air and water. The coefficient of performance for air heating increased by about 0.2 with the water temperature increasing by 1$^{\circ}C$.

  • PDF

A Condition (지열원식 냉난방 히트펌프 시스템의 상태 감시 및 열 성능 평가 기술 개발)

  • Koo, Kyung-Wan;Park, Jun-Un;Kang, Byung-Chan;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.322-326
    • /
    • 2009
  • 본 연구는 지열원식 냉난방 히트펌프 시스템의 상태를 실시간으로 감시하고 열 성능을 실시간으로 평가할 수 있도록 한 지열원식 냉난방 히트펌프 시스템의 상태 감시 및 열 성능 평가 방법에 관한 것으로서, 이러한 본 연구는, 프로그램 실행을 통하여 측정 간격이 설정되고, 다이얼로그 박스 상에서 시스템 개요, 공사개요, 히트펌프설비개요, 지열루핑 설비개요, 버퍼탱크, 건물개요 등을 입력받은 후 시스템의 개통도 이미지 파일프로그램 로딩과 각종 계측기를 통해 전기적인 데이터의 취득 기능 등의 데이터측정 준비를 위한 기본 제1단계와; 취득된 전기적인 데이터를 물리 신호로 변환한 후 기본 데이터 산정하고 결과를 도시하는 "시스템 실시간 작동 상태 감시" 기능의 제2단계와; 기본 순간치 데이터를 근거로 "시스템의 열성능 평가 변수 값 산정과 결과"를 도시하는 제3단계와; 2단계에서의 기본 데이터와 3단계에서의 열성능 평가 변수 값을 후처리용 데이터 파일로 저장하는 제4단계와; 현장에 설치된 지열원식 히트펌프 시스템의 상태를 TCP/IP 프로토콜을 활용하여 원격지(본사)에서 IP 접속을 통하여 원거리 원격 작동상태 감시 기능 및 제어를 수행하는 제5단계를 수행하게 된다.

  • PDF

Economic Evaluation of ATES Heat Pump System (ATES 열펌프 시스템의 경제성 평가)

  • Kim, Namtae;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.199-199
    • /
    • 2011
  • ATES(Aquifer Thermal Energy Storage) 열펌프 시스템은 기존의 다양한 열원 적용 시스템 대비 효율이 우수한 것으로 알려져 유럽과 미국에서 건물 냉난방 시스템으로 적용되고 있다. 특히, ATES 시스템은 기존의 냉난방 시스템 대비 경제성이 우수한 것으로 알려져 있으나 국내에서는 이에 대한 연구 결과는 전무한 실정이다. 본 연구에서는 ATES 열펌프 시스템의 실증 성능 결과를 분석하였으며, LNG 보일러와 에어컨을 사용하는 기존의 냉난방 시스템을 비교시스템으로 ATES 열펌프 시스템의 경제성 평가를 수행하였다. ATES 시스템의 연간 실증 성능 실험결과 ATES 시스템은 외기온도와 무관하게 연중 안정적인 성능을 나타내었다. 경제성 평가시에 생애주기법(Life Cycle Cost)을 적용하여 ATES 열펌프 시스템의 설치 및 운전에 필요한 총 소요비용을 산정하고, 이 결과를 바탕으로 투자회수기간법을 통해 ATES 시스템의 투자회수 기간을 산정하였다. 생애주기법 적용 시에 현재가치법을 사용하였으며, 현재가치법은 수명주기에 발생하는 모든 투자비용과 절감액을 일정한 시점을 기준으로 등가환산하는 방법을 의미한다. 현재가치법에 사용되는 현재가치는 초기비용과 현재가치계수의 곱으로 나타나는데, 여기에서 현재가치계수는 임의의 이자율로 일정기간 동안 정기적인 할부금액이 적립될 때의 현재금액을 구하기 위해 사용하는 계수를 의미한다. 전기와 LNG는 각각 2009년 7월의 (주)한국전력공사와 (주)한국가스공사의 고시요금을 적용하였다. 본 시스템은 실증 설비용량인 20RT를 대상 건물로 가정하였고, 초기투자비는 크게 공사비와 냉난방 설비 구입비로 구성되어 있으며, 기본적인 물가지표는 (사)한국물가정보(KPI)의 고시 데이터를 참조하였다. 각 시스템의 초기투자비는 ATES 시스템이 비교대상 기존 냉난방 시스템 대비 5.7배 높게 나타났다. 일일 8시간 사용기준으로 계절별 전력요금을 고려한 연간운전 비용은 ATES 시스템이 기존 시스템 대비 냉난방 시에 각각 77%와 16%를 나타내어 운전비용이 연간 절감되었고, 난방 운전 시 절감 비율이 냉방시보다 크게 나타났다. 두 시스템에 대한 생애주기비용을 산정하기 위하여 에어컨과 보일러의 기존시스템과 ATES 시스템의 가용연수를 모두 20년으로 설정하였고, 유지보수 비용은 초기투자비용의 2%로 설정하고, 할인율은 은행 예금이자를 기준으로 5%로 설정하였다. 전기와 LNG의 요금 상승률은 (사)한국물가정보를 바탕으로 각각 2%와 8%로 가정하였다. 이러한 조건에서 생애주기법을 이용한 경제성평가는 ATES 시스템의 경우 생애운전비용이 초기투자비용보다 작게 나타났으며, 기존 냉난방 시스템은 생애운전비용이 초기투자비용에 비하여 높게 나타났다. 본 연구 대상 ATES 열펌프 시스템의 실증 성능 데이터와 기존 문헌으로부터 얻은 냉난방 시스템의 성능 결과를 이용하여 생애주기 비용을 적용한 결과 ATES 시스템의 기존 시스템 대비 투자회수 기간은 6.62년으로 나타났다. 특히, 본 연구에서는 ATES 시스템이 국내 최초로 적용됨에 따라 스크린 등의 부품을 다소 고가의 제품으로 시스템에 적용하였으므로 ATES 시스템의 신뢰성과 안정성이 확보되면 초기 투자비 감소가 가능할 것으로 예상되며, 기존 시스템 대비 투자회수 기간은 더욱 감소될 수 있을 것으로 예상된다.

  • PDF

Study on Energy Consumption of Air-source, Ground-source and Dual-source Heat Pump during Intermediate Season (공기, 지열 및 복합 열원 열펌프의 중간기 에너지 소비량에 관한 연구)

  • Cho, Yeong Uk;Woo, Tea Ho;Chung, Kwang-Seop;Kim, Youngil
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • This study is to compare energy consumption of air-source, ground-source and dual-source heat pump systems during intermediate season using dynamic simulation. Ground-source heat pump has higher COP than that of air-source but requires additional power consumption of auxiliary equipment such as circulation pump. During intermediate season when the outdoor air temperature is favorable, total COP of air-source heat pump may be greater than that of ground-source when circulation pump power consumption is included. Dual-source heat pump which selects the more favorable heat source is compared with air-source only and ground-source only heat pumps for total power consumption. Results show that power consumption of dual-source heat pump is lower than that of ground-source only by 0.73%.

An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a (HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구)

  • Kim, Y.J.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.3-11
    • /
    • 1997
  • In conventional heat and vent dryer, both sensible and latent heat could not be recovered from the exhaust air, but this problem could be solved by introducing a heat pump to a conventional dryer, having a connection with cooling, dehumidifying and heating of heat pump. In this work, HFC134a as a substitute refrigerant of CFC12 adopted in heat pump and a batch type is also introduced. The variables affected on the system performance are holding temperature of a drying chamber, bypass air ratio, degree of superheat and refrigerant flowrate, etc. The moisture contents were decreased curvilinearly in the range of $86{\sim}75%$ on the wet basis. Under the constant drying temperature, the face velocity plays an important role to the drying performance. The COPs are increased in accordance with the air velocity, on the other hand the SMERs are gradually decreased.

  • PDF

수소 배기용 저온 흡착(Cryo-Sorption) 펌프의 열설계

  • 조용섭;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.45-45
    • /
    • 1999
  • 한국원자력연구소에서 개발중인 KSTAR 중성입자입사 (NBI) 가열장치의 이온원을 시험하기 위한 진공 챔버 (높이 1.2m, 폭 1.2m, 길이 2.4m)의 수소 배기는 저온 흡착 펌프를 제작하여 이용할 계획이다. 흡착제는 활성탄으로 하고, 흡착제의 냉각은 20K 12W Cold Head를 이용한다. 이 흡착제가 부착된 무산소동판을 액체 질소로 냉각된 Chevron Baffle로 열차폐한다. 이 흡착제가 수소를 배기하기 위해서는 15K 이하로 냉각이 되어야 하므로, 이에 대한 열설계가 중요하다. 흡착판에 가해지는 열부하를 평가하고, 이 열부하에서 흡착판 온도가 15K 이하가 되도록 열설계를 수행하였다. 열부하 중 가장 큰 것은 Ghevron을 통해 들어오는 복사열로, Chevron의 복사율 및 난반사도에 따라 MOnte Calro 법 전산코드를 작성하여 복사열을 계산하였다. 크기 500mm x 400mm인 흡착판에 대한 시험 결과를 바탕으로 열설계에 대한 타당성 검증 및 크기 800mm x 1400mm인 흡착판에 대해 열설계 내용에 대해 발표한다.

  • PDF

수소 배기용 저온 흡착 (Cryo-Sorption) 펌프의 열설계

  • 조용섭;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.127-127
    • /
    • 1999
  • 한국원자력연구소에서 개발중인 KSTAR 중성입자입사(NBI) 가열장치의 이온원을 시험하기 위한 진공챔버(높이 1.2m, 폭 1.2m, 길이 2.4m)의 수소 배기는 저온 흡착펌프를 제작하여 이용할 계획이다. 흡착제는 활성탄으로 하고, 흡착제의 냉각은 20K 12W Cold Head를 이용한다. 이 흡착제가 부착된 무산소동판을 액체 질소로 냉각된 Chevron Baffle로 열차폐한다. 이 흡착제가 수소를 배기하기 위해서는 15K 이하로 냉각이 되어야 하므로, 이에 대한 열설계가 중요하다. 흡착판에 가해지는 열부하를 평가하고, 이 열부하에서 흡착판 온도가 15K 이하가 되도록 열설계를 수행하였다. 열부하 중 가장 큰 것은 Chevron을 통해 들어오는 복사열로 Chevron의 복사율 및 난반사도에 따라 Monter Carlo법 전산 코드를 작성하여 복사열을 계산하였다. 크기 500mmx400mm인 흡착판에 대한 시험 결과를 바탕으로 열설계에 대한 타당성 검증 및 크기 800mmx1400mm인 흡착판에 대해 열설계 내용에 대해 발표한다.

  • PDF

Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation (가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석)

  • Kim, Min-Sung;Yoon, Seok-Ho;Baik, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1351-1358
    • /
    • 2011
  • To approximate the threshold of the fault detection and diagnosis (FDD) system, validation of the measurements is mandatory. Naturally, the system shows uncertainties due to measuring sensors - mostly thermocouples or RTDs - and due to repeatability. The uncertainty of a thermocouple comes from natural variation or a drift of the thermocouple measurement. Considering the natural variation behaves like zero-mean white noise, its natural variation can be characterized closely by the steady-state standard deviation. However, residuals between measurements and no-fault references in FDD systems show a statistical distribution with various uncertainties. In this paper, steady-state variations of measurement residuals were investigated by utilizing built-in temperature sensors in a heat pump for the model development and the final application.

Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.