• Title/Summary/Keyword: 열 탈수

Search Result 86, Processing Time 0.025 seconds

A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates (III) -Numerical Analysis of Heat Transfer in Ca(OH)2 Dehydration Packed Bed- (화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(III) -Ca(OH)2 탈수반응층의 전열해석-)

  • Park, Young-Hae;Lee, Young-Sei;Kim, Jong-Shlk
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1181-1191
    • /
    • 1996
  • To develope chemical heat pump, which is operated by heat of high temperature using available energy sources such as solar heat and many kinds of waste thermal energy we have studied theoretically the enhancement effects of inserted fins on the rate of heat transfer and reaction in cylinderical $Ca(OH)_2$ packed bed reactor. The results obtained by numerical analysis about profiles of temperature, completion time of reaction and exothermic heat amount released from the reactor read as the inserted copper fins in reator reduce the completion time of dehydration reaction in packed bed by half, and the rate of thermochemical reaction depends on the temperature and concentration, and it is also governed by the boundary conditions and the rate of heat transfer in the particle packed bed.

  • PDF

The Effect of Organic Acids on Dewatering Efficiency of Soybean Milk Residue by Hydraulic Press (유기산이 두유박의 압착 탈수율에 미치는 영향)

  • Pyun, Yu-Ryang;Cho, Won-Il;Lee, Yoon-Su;Kwon, Ick-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.638-643
    • /
    • 1996
  • The efficiency of dewatering of soybean milk residue was improved by hydraulic pressing after pH adjustment to 4.5 with organic acids such as acetic and lactic acids. Water content of raw soybean milk residue was reduced from 80% to 72% by pressing after pH adjustment, while only to 78% by the conventional hydraulic press. The water content of the residue after pH adjustment was further reduced to 63% by hydraulic pressing with ohmic heating. The pH adjustment facilitated separation of cake from the filter cloth and reduced the solid content of the expressed liquid from 10 to 3%.

  • PDF

A Study on the Viscosity Characteristics of Dewatered Sewage Sludge according to Thermal Hydrolysis Reaction (열가용화 반응에 의하여 탈수된 하수슬러지의 점도 특성에 관한 연구)

  • Song, Hyoung Woon;Han, Seong Kuk;Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • demand for a low-cost treatment technology is high because the sewage sludge has an 80% or higher water content and a high energy consumption cost. This study apply the thermal hydrolysis reaction that consumes a small amount of energy for sludge treatment. The purpose of this study is to quantify the viscosity of sewage sludge according to reaction temperature. we measured continuously the torque of dewatered sludge by the reaction temperature. As the reaction temperature increased, the dewatered sludge is thermal hydrolysis under a high temperature and pressure. Therefore, the bond water in the sludge cells comes out as free water, which changes the dewatered sludge from a solid phase to slurry of a liquid phase. The results of the viscosity measurements according to the reaction temperature showed that the viscosity was very high at $270,180kg/m{\cdot}sec$ at a temperature of 293K, but rapidly decreased with increases in the reaction temperature to $12kg/m{\cdot}sec$ at a temperature of 400K and to $4kg/m{\cdot}sec$ at a temperature of 460K or higher, similar to the changes in the viscosity of water. And we was obtained the viscosity function of boundary condition for the optimal design of thermal hydrolysis reactor by numerical modeling based on the this results.

Rate Enhancement of Thermal Decomposition Reaction in the $Ca(OH)_2$ Packed Bed ($Ca(OH)_2$ 충전층의 열분해 반응 촉진)

  • Chung, Soo-Yull;Kim, Do-Wan;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.73-84
    • /
    • 1995
  • The present paper is on the utilization of a thermal decomposition reaction $Ca(OH)_2=CaO+H_2O$, for thermal energy storage. One of the important problems in this case is how to heat up and decompose the particle of $Ca(OH)_2$ effectively where the thermal conduction is poor. In this study, the effects of Cu-plates which are placed in the $Ca(OH)_2$ packed bed as heat transfer fins are investigated experimentally. The results show that the Cu-plates are very effective for heat transfer and the thermal decomposition in the $Ca(OH)_2$ packed bed. The amount of time to dehydrate took less than a half than that without fins under the conditions of this study.

  • PDF

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

Thickening and Dewatering of Municipal Wastewater Sludge : Separate and Combined Treatment of Primary and Secondary Sludge (도시하수슬러지의 농축과 탈수 : 1차와 2차슬러지의 분리 및 혼합처리특성비교)

  • Lee, Jin-Woo;Choi, Hoon-Chang;Choi, Jeong-Dong;Jung, Gyung-Yeung;Jun, Seok-Ju;Kwon, Soo-Yul;Ahn, Young-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.93-100
    • /
    • 2005
  • Comparative thickening and dewatering characteristics of municipal wastewater sludge were investigated in terms of separated and combined treatment of primary and secondary BNR sludge. Also, various conditioning methods such as cation polymer addition, steam and ultrasonication treatment were examined to improve dewaterability of sludge. The dewaterability was measured by using specific resistant test, wedge zone simulator and centrifuge. The result of the sludge thickening test revealed that separated thickening was better in terms of solids recovery and supernatant quality. Particularly, the thickening of primary sludge with high solids (about 3.5% TS) showed very poor solid separation. The addition of cation polymer showed better conditioning characteristic for dewatering and the optimal polymer dosage was 0.26% for primary sludge, 0.43% for secondary sludge and 0.38% for combined sludge. Contrary to the result of the thickening, the dewatering test revealed that dewatering of the combined sludge is better than that of separated sludge, representing better solids separation and filtrate quality. The polymer addition was essential to improve dewaterability in filter (belt) press type dewatering but it was inefficient for the dewatering of secondary sludge only. The centrifuge type dewatering showed better performance and the dewaterability was slightly improved when the polymer was added. Based on the results of this research a sustainable sludge treatment process, particularly in terms of the recycle water quality and solids recovery, was proposed.

A Study on the Simulation of Chemical Heat Pump System Based on 2-Propanol /Acetone/Hydrogen System (2-Propanol/Acetone/Hydrogen 반응계로 구성된 화학적 열펌프 시스템의 모사 연구)

  • 김범재;여영구;정연수;송형근
    • Journal of the Korea Society for Simulation
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • 2-propanol/acetone/hydrogen 반응계로 구성된 화학적 열펌프 시스템은 낮은 온도(82.5~$90^{\circ}C$)에서의 2-propanol의 탈수소화 반응과 높은 온도(약 $200^{\circ}C$ 부근)에서의 acetone의 수소화반응을 이용하여 열을 고품위화 시키는 장치이다. 본 연구에서는 이 시스템의 해석 및 설계를 목적으로 이 시스템에 대한 수치적인 모델들을 세우고 Sequential modular approach를 이용하여 시스템의 모사를 수행하였다. 또한 에너지 효율을 최대화하기 위하여 열펌프 시스템에서의 환류비의 영향을 규명하였다. 모사결과 이 시스템의 scale up을 위한 정량적인 정상상태 운전조건들을 구할수 있었으며 두 반응의 반응 전화율이 다르더라도 반응물의 유량의 차이를 통하여 두 반응열이 거의 같아지는 것을 알수 있었다. 아울러 주어진 운전조건에서 증류의 환류비는 최소환류비 근처의 최적값이 존재함을 알수 있었다.

  • PDF

Pervaporation process simulation for ethanol dehydration (에탄올 탈수를 위한 투과증발 공정 모사)

  • 이규현;유제강;장재화;안승호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.38-39
    • /
    • 1995
  • 최근 자동차 대체 연료로 가솔린에 10% 무수에탄올이 혼합된 Gasohol 사용에 관한 관심이 고조되고 있으며, 이는 Gasohol이 자동차 배기 가스중의 일산화탄소 및 탄화수소 함유량을 감소시켜 대기 오염을 줄일 수 있기 때문이다. Gasohol에 사용되는 무수에탄올의 농도는 99.5% 이상이어야 하며, 이러한 고순도의 에탄올을 제조하기 위해서는 물과 에탄올의 공비 혼합물(95.6% 에탄올)로부터 공비증류, 분자체 흡착, 투과증발과 같은 분리 조작을 이용하여 물을 제거하는 공정이 필요하다. 현재 에탄올 탈수에는 공비증류가 많이 사용되고 있으나 공비증류는 에너지 사용량이 많을 뿐더러 유독한 Entrainer를 첨가하기 때문에 투과증발과 같은 저 에너지 소비형, 환경친화적인 공정으로의 전환이 이루어지고 있다. 에탄올 탈수용 투과증발 플랜트는 전세계 20여개가 가동되고 있으며, 상업화된 플랜트의 대부분은 독일의 Deutsche Carbone사가 제조한 PVA/PAN 투과증발 복합막을 사용하고 있다. 투과증발 시스템은 물에 대한 친화도가 높은 투과증발막 및 모듈, 기타 분리 구동력을 높여주기 위한 Heater, 진공펌프, 냉각기, 열 교환기 등의 주변 설비로 구성되며, 투과증발 시스템 개발을 위해서는 우수한 막/모듈 제조와 아울러 최적 공정 설계 기술 개발이 필수적이라 하겠다.

  • PDF

Dewatering of Soybean Milk Residue by Hydraulic Press with Ohmic Heating (Ohmic Heating을 이용한 두유박의 압착탈수)

  • Cho, Won-Il;Pyun, Yu-Ryang;Lee, Youn-Soo;Kwon, Ik-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.324-329
    • /
    • 1996
  • In order to develop a novel dewatering process for soybean milk residue, hydraulic press with ohmic heating was built and its expression conditions were examined. The electric conductivity of raw soybean milk residue was 0.128 S/m and increased linearly with increasing temperature. Water content of the residue could be reduced to 74% with the conventional hydraulic press, but to less than 70% by applying ohmic heating to the hydraulic press. The most effective dewatering was achieved by applying alternative current with 5 kHz frequency at 60 V during expression. The solid content of the expressed liauid was markedly reduced from 10% to 3.3% by ohmic heating during expression. Temperature of the cake rose to above $95^{\circ}C$ during the dewatering due to ohmic heating.

  • PDF

Dehydration Characteristics of Cationic Surfactant-Modified Montmorillonite (양이온성 계면활성제로 표면개질된 몬모릴로나이트의 탈수 특성)

  • Seung Yeop Lee;Soo Jin Kim
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.305-314
    • /
    • 2002
  • The dehydration of hexadecyltrimethylammonium (HDTMA)-exchanged montmorillonite has been studied using X-ray diffractometry (XRD) and differential scanning calorimetry (DSC). The dehydration in HDTMA-montmorillonite seems to influence the swelling behavior of the organo-clay during heating. The basal d(001) spacing vs temperature curve of the HDTMA-montmorillonite has one broad swelling edge with a shoulder on the low-temperature side. We believe that the shoulder at $100^{\circ}C$ for the HDTMA-montmorillonite is due to interlayer swelling induced by the initial rearrangement of surfactants, and the second edge at $200^{\circ}C$ is caused by interlayer swelling resulting from the secondary vertical reorientation of alkyl chains. It seems that the dehydration of organo-clay induces a reorientation of the alkyl chains by transition to more vertical position relative to the silicate sheets, allowing instantly greater d-spacing.