• Title/Summary/Keyword: 열 전달 계수

Search Result 248, Processing Time 0.027 seconds

Measuring Convective Heat Transfer Coefficient of Nanofluids Considering Effect of Film Temperature Change over Heated Fine Wire (막온도 변화를 고려한 가는 열선주위 나노유체의 대류열전달계수 측정 실험)

  • Lee, Shinpyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.725-732
    • /
    • 2013
  • This study examined the convective heat transfer characteristics of nanofluids flowing over a heated fine wire. Convective heat transfer coefficients were measured for four different nano-engine-oil samples under three different temperature boundary conditions, i.e., both or either variation of wire and fluid temperature and constant film temperature. Experimental investigations that the increase in the convective heat transfer coefficients of nanofluids in the internal pipe flow often exceeded the increase in thermal conductivity were recently published; however, the current study did not confirm these results. Analyzing the behavior of the convective heat transfer coefficient under various temperature conditions was a useful tool to explain the relation between the thermal conductivity and the boundary layer thickness of nanofluids.

Analysis of density diffusion analysis by Fick's laws in the human body (픽법에 의한 생체 내의 농도 확산 분석)

  • Che, Gyu-Shik
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.4
    • /
    • pp.657-664
    • /
    • 2012
  • One of the methods to transmit solute through solvent is diffusion. Various particles or molecules including several charged ions in the body diffuse from high density region to low density due to density difference or external electric field. This kind of mechanism is due to thermal motion of each solute molecules. These situations can be deployed using Fick's first and second laws that govern diffusion phenomena in the body. I analysis these diffusion status of material in the body using above mentioned Fick's laws and then implement them through illustration.

Overall Heat Transfer Coefficient Measurement of Covering Materials with Thermal Screens for Greenhouse using the Hot Box Method (핫박스를 이용한 온실 피복재 및 보온재의 조합에 따른 관류열전달계수 측정)

  • Diop, Souleymane;Lee, Jong-Won;Na, Wook-Ho;Lee, Hyun-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.1-7
    • /
    • 2012
  • 본 연구의 목적은 국내에서 상용되고 있는 온실 피복재 및 보온재의 조합에 따른 관류열전달계수를 핫박스를 이용하여 평가하는 것이다. 온실용 일중 및 이중 피복재와 이중 보온재의 조합에 대하여 야간천공복사 차단여부에 따른 관류열전달계수를 핫박스를 이용하여 실외에서 측정하였다. 처리조건은 일중피복, 이중피복, 이중피복과 이중 마트보온재 및 이중피복과 이중 다겹보온재의 조합조건과 천공복사 유무에 따른 조건이며 총 8가지이다. 제작된 핫박스는 상시 변화하는 외부의 기상조건하에서도 내부온도를 설정된 온도로 일정하게 잘 유지할 수 있었다. 온실 피복재 및 보온재의 관류열전달계수를 측정하는 실내용 측정장치는 반드시 야간천공복사를 모의할 수 있는 측정장치가 되어야 할 것이다. 야간복사를 차단함으로서 온실의 열 손실을 줄여 보온효과를 얻을 수 있을 것으로 분석되었다. 모든 피복방식에 대해 야간복사 차단장치 유무에 관계없이 높은 풍속에서의 관류열전달계수가 낮은 풍속에서보다 더 큰 것으로 나타났다. 본 연구에서 사용된 측정기법을 사용하면 국내에서 생산되는 피복재 및 보온재의 관류열전달 특성을 정량적으로 비교할 수 있을 것으로 기대된다.

Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water(2) (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능(2))

  • Park, Geun-Woo;Lee, Eung-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.15-19
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 하는 지열히트펌프의 Pond Loop형 열교환기를 개발하기 위하여 미국에서 상용화된 Slim-Jim 열교환기와 본 연구에서 자체설계, 제작한 Pond-loop type의 열교환기를 유동이 없는 유출수조 내에서 수조온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량의 변화를 측정하였다. 그 결과 유출수를 Heat Source로 사용하는 경우 Slim-Jim에서는 $8,000{\sim}11,000 kcal/hr$의 열량이 전달되었고, 자체 제작한 열교환기에서는 $11,000{\sim}16,000kcal/hr$의 열량이 전달되었다. 유출수를 Heat Sink로 사용할 경우 Slim-Jim에서는 $2,500{\sim}7,000 kcal/h$의 열량이 전달되었고, 자체제작한 열교환기의 경우, $6,800{\sim}14,00 kcal/hr$의 열량이 전달되었다. 측정된 열전달량을 바탕으로 총괄열전달계수를 구한 결과 Slim-Jim 열교환기의 경우 $210{\sim}340 kcal/hr\;m^2{\circ}C$, 자체개발한 열교환기의 경우 $350{\sim}590 kcal/hr\;m^2{\circ}C$로 나타나 자체 개발한 열교환기의 열전달 성능이 비교적 우수함을 입증하였다.

  • PDF

Two dimensional flow and heat/mass transfer characteristics in rectangular wavy duct with corrugation angle (2차 유동 영역에서 꺽임각 변화에 따른 주름진 사각 덕트에서의 열/물질전달 및 유동 특성)

  • Kwon, Hyun-Goo;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2267-2272
    • /
    • 2007
  • The present study investigates the two dimensional flow and heat/mass transfer characteristics of wavy duct with various corrugation angles. For the heat/mass transfer coefficients, a naphthalene sublimation technique is used. Numerical analysis and wall pressure measurement show detailed two dimensional flow features. The corrugation angles change from 145$^{\circ}$ to 100$^{\circ}$. The operating Reynolds numbers based on the duct hydraulic diameter vary from 700 to 3,000. The duct aspect ratio maintains 7.3. On the pressure wall, strong flow mixing enhances heat/mass transfer coefficients at the front position. In addition, the rear side of pressure wall, the near of peak, is affected by the acceleration and the shedding of main flow. On the suction wall, however, flow separation and reattachment lead to the valley and the peak of heat/mass transfer coefficient. Also, highly increasing boundary layer at the suction wall affects the decrease of heat/masst transfer. As decreasing corrugation angles, the spanwise average Sherwood number increases and the peak or the valley positions of the local Sherwood number are varied.

  • PDF

Measurements of Heat (Mass) Transfer Coefficient on the Surface of a Turbine Blade with n High Turning Angle Using Naphthalene Sublimation Technique (큰 회전각을 가지는 터빈 블레이드 표면에서 나프탈렌승화법을 이용한 열(물질)전달계수 측정)

  • Gwon, Hyeon-Gu;Lee, Sang-U;Park, Byeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1077-1087
    • /
    • 2002
  • The heat (mass) transfer characteristics on the blade surface of a high-turning first-stage turbine rotor for power generation has been investigated by employing the naphthalene sublimation technique. A four-axis profile measurement system is developed successfully for the measurements of local sublimation depth on the curved surface In the leading edge region, there is a good agreement between the present heat (mass) transfer data and the previous result on a turbine blade with a moderate turning angle, but some discrepancies are found in the mid-chord heat (mass) transfer between the two results. The local heat (mass) transfer on the present suction surface is greatly enhanced due to an earlier boundary transition, compared with that on a turbine blade with a moderate turning angle, meanwhile there is only a slight change in the pressure-side heat (mass) transfer between the two different turbine rotors. In general, the heat (mass) transfer augmentation by the endwall vortices is found much higher on the suction surface than on the pressure surface.

Evaporation Heat Transfer Characteristics of Carbon Dioxide in the Inner Diameter Tube of 4.57 mm (4.57 mm 세관 열교환기 내 이산화탄소의 증발열전달 특성)

  • Ku, Hak-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.145-151
    • /
    • 2007
  • The evaporation heat transfer coefficient of $CO_2$(R-744) in a horizontal tube was investigated experimentally. The main components or the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57 mm. The experiments were conducted at mass flux of 200 to $500\;kg/m^2s$, saturation temperature of -5 to $5^{\circ}C$, and heat flux of 10 to $40\;kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not effect nucleate boiling too much. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develope reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

A New Approach to Obtain Time Series for Dynamic Water Quality Analysis (동적 수질분석을 위한 시계열 자료 획득 방안 제시)

  • Park, Chae-Il;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1012-1016
    • /
    • 2006
  • 최근 오염총량관리제도를 위한 오염부하량의 관리문제가 대두되면서 이를 위한 수질분석의 중요성이 인식되고 있다. 그러나 시간적 변화를 가진 유입유량, 유입부하량 자료의 한계로 인하여 기준유량을 대상으로 하는 정적수질분석의 결과가 환경정책에 반영되고 있는 실정이며, 이는 하천유량의 변동과 강우 시 비점오염부하량을 무시한 지극히 제한된 분석에 국한되어 있다. 따라서 시간적 변화를 가진 동적수질분석의 결과가 정책에 반영되기 위해서는 자료의 확보가 우선이다. 본 연구에서는 월 별, 소유역 별 시계열 자료 확보를 위하여 합리적이고 사용이 용이한 방법을 제시하였다. 유출량의 경우, 기존의 비유량법과는 달리 저류효과를 고려한 토양수분 저류구조 Tank모형을 적용하여 장기간의 유출량을 산정하였고, 유출농도의 경우, 기존 인접유역의 동일 유달계수 적용과는 달리, 월 오염부하총량비와 유역오염부하 전달함수를 이용하여 월 별, 소유역 별, 수질변수 별 유출농도를 산정하였다. 산정된 유출량과 유출농도는 남강댐 상류유역 하천에서 WASP 모형을 가지고 동적수질분석을 하기 위하여 적용되었다. 그 결과 적절한 오염물질 농도곡선을 얻을 수 있었으며, 제안된 가정의 적용 가능성은 충분하였다.

  • PDF

Heat(Mass) Transfer Characteristics in the Tip-Leakage Flow Region of a High-Turning Turbine Rotor Blade (회전각이 큰 터빈 동익 누설유동 영역에서의 열(물질)전달 특성)

  • Lee, Sang-Woo;Kwon, Hyun-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.535-544
    • /
    • 2004
  • The heat (mass) transfer characteristics in the tip-leakage flow region of a high-turning first-stage turbine rotor blade has been investigated by employing the naphthalene sublimation technique. The heat transfer data in the tip-leakage flow area for the tip clearance-to-span ratio, h/s, of 2.0% are compared with those in endwall three-dimensional flow region without tip clearance (h/s : 0.0 %). The result shows that the thermal load in the tip-leakage flow region for h/s = 2.0% is more severe than that in the endwall flow region for h/s : 0.0%. The thermal loads even at the leading and trailing edges for h/s = 2.0% are found larger than those for h/s = 0.0%. The tip-leakage flow results in heat transfer augmentations near the tip on both pressure and suction sides in comparison with the mid-span results.

Analysis of Convective Heat Transfer Characteristics for the Compact Heat Exchanger with Flat Tubes and Plate Fins Having a Non-symmetric Staggered Arrangements (비대칭 엇갈림 배열로 구성된 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 특성 해석)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.5
    • /
    • pp.318-325
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchanger with flat tubes and continuous plate fins having a symmetric and non-symm etric staggered arrangements. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental results. In order to investigate the flow and heat transfer features by periodic boundary conditions, the three blocks were used. Predicted heat transfer coefficients between the three blocks are similar while there are relatively differences, compared with the experimental data. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.