• Title/Summary/Keyword: 열 순환

Search Result 850, Processing Time 0.026 seconds

Recurrent Neural Network Based Distance Estimation for Indoor Localization in UWB Systems (UWB 시스템에서 실내 측위를 위한 순환 신경망 기반 거리 추정)

  • Jung, Tae-Yun;Jeong, Eui-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.4
    • /
    • pp.494-500
    • /
    • 2020
  • This paper proposes a new distance estimation technique for indoor localization in ultra wideband (UWB) systems. The proposed technique is based on recurrent neural network (RNN), one of the deep learning methods. The RNN is known to be useful to deal with time series data, and since UWB signals can be seen as a time series data, RNN is employed in this paper. Specifically, the transmitted UWB signal passes through IEEE802.15.4a indoor channel model, and from the received signal, the RNN regressor is trained to estimate the distance from the transmitter to the receiver. To verify the performance of the trained RNN regressor, new received UWB signals are used and the conventional threshold based technique is also compared. For the performance measure, root mean square error (RMSE) is assessed. According to the computer simulation results, the proposed distance estimator is always much better than the conventional technique in all signal-to-noise ratios and distances between the transmitter and the receiver.

Characteristics of Clinker in Circulating Fluidized Bed Combustor (순환유동층 연소로의 클링커 특성)

  • 이준일;정봉진;고정민;선도원;최정후;김수섭;한기홍;우형관;서영태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.539-544
    • /
    • 2003
  • 국내 산업체에 열병합 또는 발전용 보일러로 보급되어 있는 순환유동층 연소로는 저렴한 연료비와 높은 열효율, 탁월한 공해저감효과를 나타내는 장점을 가지고 있으나 순환유동층 연소로의 운전기술은 체계적으로 정리된 지침이 마련되어 있지 않으며, 이러한 기술정보의 부재가 신규보일러의 보급에 장애가 되고 있다.(중략)

  • PDF

강제순환상실시 CANDU-6 주열수송계통의 압력천이상태 해석

  • 김영보;한상구;김선철;정종식;주경인
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.160-165
    • /
    • 1996
  • 중수로형 원전에서 일차측 냉각수를 순환시키는 주연수송펌프가 정상운전중 갑자기 정지하는 사고를 강제순환 상실사고라 한다. 강제순환 상실사고는 주열수송계통을 과도압력상태로 만들며, 일반적으로 펌프에 공급되는 IV등급전원 상실사고와 기계적 손상에 의한 주열수송펌프 고착사고로 분류할 수 있다. 본 논문에서는 강제순환 상실사고에 대하여 중수로계통설계의 열수력 해석코드인 SOPHT를 이용하여 주열수송계통의 과도압력상태를 해석하였다. 카나다 원자력 규제위원회(AECB)의 과압 방지조건인 R-77 요구조건에 적절한 유효트립변수를 결정하기 위한 해석이 수행되었으며, 증기발생기 오염상태와 액체방출밸브 작동여부가 고도압력상태에 미치는 영향을 고찰하여 보수적 조건을 제시하였다. 또한 위와같이 결정된 보수적 조건을 근거로 ASME 코드에 명시된 과압 한계치에 대한 만족여부와 과도압력상태에 따른 주열수송계통의 열수력학적 거동을 고찰하여 보았다. 해석결과, 강제순환상실사고시 주열수송계통은 R-77 요구조건에 적합한 원자로트립변수에 따라 안정화되었으며, 계통의 최대압력은 ASME 코드가 규정한 한계치내에 있음을 알 수 있었다.

  • PDF

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Experiments on the Characteristic of Storage Tank in In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열시스템의 축열조 특성 실험)

  • 최인수;김재돌;윤정인
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.366-371
    • /
    • 2000
  • 본 연구는 동적형 빙축열시스템에 있어서 증발판이 축열조 상부에 설치되어 생성된 얼음을 주기적으로 분리, 이탈시켜 하부에 설치된 축열조에 저장하는 기존의 하베스트형 빙축열시스템과는 반대로 축열조 내에 증발판을 설치하여 수중에서 얼음을 생성시키고 분리시켜 부럭에 의해 얼음을 띄워 저장하는 새로운 방식의 수중 하베스트형 빙축열시스템 개발에 관한 연구이다. 본 방식은 축열조 내에 증발판이 설치되어 제빙과 탈빙이 이루어짐으로서 기존 시스템에 설치되는 순환펌프나 순환수 분배기 및 배관 등의 설비가 불필요하고, 또한 조내 물과 증발판이 직접접촉에 의해 열교환이 이루어지므로 기존 공기 중에서의 열교환 방식보다 전열효율이 우수한 장점을 가지고 있다. 따라서 본 연구에서는 상기의 수중 빙제조 방식에있어 빙 제조시와 방냉시 축열조의 열특성을 실험적으로 밝혀 시스템 최적화 및 성능 향상에 대한 기초 자료를 제공하고자 하였다.

  • PDF

Reactive Power Circulation based Active Thermal Control for Paralleled Power Converters for Wind Turbine (풍력발전용 병렬형 컨버터를 위한 무효전력순환 기반 능동 열 제어기법)

  • Ko, Youngjong
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.251-252
    • /
    • 2020
  • 화석연료 사용으로 발생하는 환경문제 대처방안으로 풍력 등 신재생 에너지원 사용의 필요성이 강조되고 있으며, 이러한 사회적 요구에 따라 신재생 에너지 발전 시스템의 대용량화 추세에 있다. 시스템 대용량화에 있어 안정적인 에너지 발전과 공급을 위해 전력변환장치의 신뢰성 향상이 필요하다. 특히, 풍력발전시스템의 경우 돌풍 등 일정하지 않은 풍속으로 인하여 전력변환장치의 잦은 고장이 발생하고, 이는 전체 시스템의 신뢰성 결정에 주된 영향을 미친다. 본 논문에서는 병렬형 전력변환장치에서 높은 고장률을 보이는 스위칭 소자의 열적 스트레스를 줄이기 위한 무효전력순환 기반 능동 열 제어기법을 제안한다. 제안한 기법의 동작특성을 이론적으로 분석하고, 열 회로망 시뮬레이션을 통해 그 영향을 검증한다.

  • PDF

Thermal Efficiency Analysis of the Conical Solar Concentrator According to the Black Coating of Absorber (흡수기 도색 여부에 따른 원추형 집광기 집열효율 분석)

  • Hwang, Seong Geun;Na, Mun Soo;Woo, Sung Jae;Lee, Joo Hee;Lee, Gwi Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.125-125
    • /
    • 2017
  • 본 연구에서 원추형 태양열 집광기의 흡수관 표면의 흑색 도색 여부에 따른 효율분석을 수행하였다. 원추형 집광기 시스템은 열 손실 최소화 및 집광비가 우수한 $45^{\circ}$의 원추각을 갖는 원추형 집광기를 설계 및 제작하였다. 원추형 태양열 집광시스템은 열매체 축열을 위한 온도센서가 내장된 축열조와 태양에너지를 집열시키는 원추형 집광기, 유량측정을 위한 유량계, 열매체의 강제순환을 위한 펌프로 구성되어있다. 또한 지속적인 태양추적을 위해 2축 태양 추적 장치를 설치하였다. 흡수관은 원추형 집광기의 중심부에 설비되었으며, 열매체의 순환을 위해 이중 열교환기 구조로 제작되었다. 흡수관의 길이는 열 손실을 최소화하기 위하여 집광기의 높이와 동일하게 설계하였다. 원추형 집광시스템의 작동유체인 물은 펌프에 의해 흡수관과 축열조를 강제순환 하게되고, 용량이 70L인 축열조에 흡수관으로부터 흡수된 태양 복사열이 저장된다. 원추형 집광시스템의 성능실험은 청명한 날 유량 2L/min, 4L/min, 6L/min에 대해 수행되었으며, 집열효율을 계산하여 비교 및 분석하였다. 흑색으로 도색된 흡수기를 부착한 원추형 집광시스템의 집열효율은 82.25%로 나타났으며, 무 도색 흡수관을 갖는 원추형 집광시스템은 73.26%의 집열효율을 나타내었다. 따라서 본 연구를 통해 흡수관 표면의 흑색 도색이 원추형 집광시스템의 집열효율에 큰 영향을 미친다는 것을 알 수 있었다.

  • PDF

Heat Integration and Economic Analysis of Dry Flue Gas Recirculation in a 500 MWe Oxy-coal Circulating Fluidized-bed (CFB) Power Plant with Ultra-supercritical Steam Cycle (순환 유동층 보일러와 초초임계 증기 사이클을 이용한 500 MWe급 순산소 화력발전소의 건식 재순환 흐름의 열 교환 및 경제성 분석)

  • Kim, Semie;Lim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • This study presented techno-economic analysis of a 500 MWe oxy-coal power plant with CO2 capture. The power plant included a circulating fluidized-bed (CFB), ultra-supercritical steam turbine, flue gas conditioning (FGC), air separation unit (ASU), and CO2 processing unit (CPU). The dry flue gas recirculation (FGR) was used to control the combustion temperature of CFB. One FGR heat exchanger, one heat exchanger for N2 stream exiting ASU, and a heat recovery from CPU compressor were considered to enhance heat efficiency. The decrease in the temperature difference (ΔT) of the FGR heat exchanger that means the increase in heat recovery from flue gas enhanced the electricity and exergy efficiencies. The annual cost including the FGR heat exchanger and FGC cooling water was minimized at ΔT = 10 ℃, where the electricity efficiency, total capital cost, total production cost, and return on investment were 39%, 1371 M$, 90 M$, and 7%/y, respectively.