• Title/Summary/Keyword: 열 성능

Search Result 4,257, Processing Time 0.034 seconds

Study on Analysis and Evaluation of Performance for Evacuated Tubular Solar Collector System (진공관형 태양열 집열장치의 성능평가 및 해석 연구)

  • Chun, Tae-Kyu;Ahn, Young-Chull
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.112-119
    • /
    • 2013
  • The thermal performance for test system with evacuated tubular solar collector is experimentally investigated to obtain the basis data for developing new type solar collector. For this purpose, the test system was designed using CATIA and then after being manufactured, the system was tested using evacuated tubular solar collector. Numerical analysis, furthermore, was performed using ANSYS Fluent V.13 for glass evacuated tubular solar collector. The results showed that as setting temperature difference(${\Delta}T$) of system was increased, total operating(working) time was almost same in all cases, even though operating count was decreased. The results of numerical analysis showed that as temperature of solar absorber in glass evacuated tubular solar collector was high, the drop-rate of temperature of center part was increased.

Frost Heave of Frost Susceptible Soil According to Performance of Thermo-syphon (열 사이펀 성능에 따른 동상민감성 지반의 거동 비교)

  • Park, Dong-Su;Shin, Mun-Beom;Seo, Young-Kyo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.27-40
    • /
    • 2021
  • The construction method to prevent the frost heave or thaw settlement is called the ground stabilization method, and the thermo-syphon is one of the typical ground stabilization methods. The thermo-syphon has recently been developed with a simple analysis model and thermal analysis has been carried out, but the frost heave of frost susceptible soil was not considered. This study was conducted using ABAQUS internal user subroutine to develop the numerical analysis model (Coupled thermo-mechanical) that can simultaneously perform thermal analysis for the temperature change of the soil according to the thermo-syphon and structural analysis to predict the frost heave of the soil accordingly. As a result of the numerical analysis, the frost heave of the soil decreased as the performance of the thermo-syphon increased. As for the main results, when the thermo-syphon which has contain 25%, 50%, and 100% of refrigerant filling ratio was applied, the reduction ratio of the frost heave was 5.5%, 14.4%, and 21% respectively.

Experimental study on the performance of heat pump system using $CO_2$ (이산화탄소용 열펌프시스템의 성능특성에 관한 실험적 연구)

  • Jang, Seong-Il;Jeon, Min-Ju;Yu, Tae-Guen;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.55-56
    • /
    • 2006
  • 냉매 충전량과 이차유체의 입구조건은 $CO_2$용 열펌프시스템의 성능실험에서 중요한 제어변수이다. 따라서, 열펌프사이클의 적용과 난방성능 향상을 위해 제어변수의 특성을 조사하는 것이 필요하다. 본 논문에서, $CO_2$용 열펌프 사이클의 성능 실험은 여러 가지 냉매 충전량에서 이차유체 입구조건에 변화를 주어 수행 되었다. 실험결과, 난방COP는 냉매 충전량이 증가함에 따라 1158g의 냉매 충전량에서 최대가 되었다가 감소하는 경향이 나타나며, 이는 COP가 최대가 되는 냉매충전량이 존재함을 나타낸다. 또한, 난방성능은 가스쿨러내 이차유체의 질량유량의 증가에 따라 증가하였다. 가스냉각기내 2차유체의 입구은도가 $10^{\circ}C$에서 $40^{\circ}C$로 증가하면, 난방용량, 압축일량, 토출압력은 각각 -8.57%, -35.89%, 32.78%로 변화했으며, 증발기 2차유체의 입구 온도가 감소하였을 때 난방COP는 감소하는 경향을 보였다.

  • PDF

Study on an Absorption Heat Transformer Using Methanol-Glycerine System (메탄올-글리세린을 이용한 변형 흡수 열 펌프 연구)

  • 민병훈
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.237-242
    • /
    • 2000
  • 에너지 회수를 위한 변형 흡수 열 펌프 연구를 메탄올-글리세린을 이용하여 수행하였다. 이 물질의 상 평형 열역학 데이터를 이용하여 변형 흡수 열 펌프의 이론적 성능계수 값을 각 기관의 조업 조건에 따라 계산하였다. 70~8$0^{\circ}C$의 공업 폐열 온도를 가지고 4$0^{\circ}C$ 온도상승 시킬 때 성능계수 50% 이상을 얻을 수 있었다.

  • PDF

Design and Performance Tests of a Cryogenic Blower for a Thermal Vacuum Chamber (열진공 챔버용 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.11
    • /
    • pp.1008-1015
    • /
    • 2015
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in extremely cold/hot temperatures and vacuum conditions. A thermal vacuum chamber used to perform the thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the gaseous nitrogen (GN2) closed loop thermal control system for thermal vacuum chambers. A final goal of this research is development of cryogenic blower. Design requirements of a blower are 150 CFM flow rate, 0.5 bara pressure difference, hot and cold temperatures. This paper describes the performance analysis of impeller by 1D, CFD commercial software, the design of the thermal protection interface between the driving part and the fluid part. The performance of the cryogenic blower is confirmed by test at the standard air condition and is verified by on the thermal vacuum chamber at the real operating condition.

Early Processings for an Improvement in Handwritten Digit String Recognition (필기 숫자열 인식률 향상을 위한 초기 처리에 관한 연구)

  • 윤성수;변영철;김경환;최영우;이일병
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.455-457
    • /
    • 1999
  • 필기 숫자열의 인식성능을 향상시키기 위해서는 물론 인식기 자체의 성능 개선도 필요하지만 인식기에서 필요로 하는 정보를 제공해주는 초기단계의 개선 역시 매우 중요하다. 낱자와는 달리 숫자열 인식에서는 인식기에서 필요한 단위로 입력 데이터를 분할해야만 하는데 잡영, 기울어짐, 접촉 등의 원인에 의해서 쉽게 분할해내기 어렵기 때문이다. 본 논문에서는 이런 문제점들을 극복하기 위한 방법들은 제시하였으며 NIST 숫자열 데이터에 적용해 본 결과 16%의 성능 향상을 보였다.

  • PDF

A Study on the Frame Structure for the Performance Improvement of Digital Terrestrial TV Receiver (디지털 지상파 TV 수신 성능 향상을 위한 데이터 프레임 구조에 관한 연구)

  • 박성우;김철민;김대진;전희영
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.313-316
    • /
    • 2000
  • 본 논문에서는 동적 다중경로 환경에 대한 DTV수신 성능 개선을 위하여 정보 데이터 세그먼트 부분에서는 Stop and Go 알고리즘을 사용하고 313 세그먼트 중 한 개만이 훈련열로 쓰이는 기존의 ATSC 표준의 데이터 프레임 구조보다 더 많은 훈련열이 들어있는 새로운 데이터 프레임 구조를 제안한다. 정보가 없는 널 패킷을 훈련열로 대체하기 때문에 데이터의 손실 없이 더 많은 훈련열을 사용하여 특히 동적 다중경로 환경에서 등화기의 수렴 특성을 개선할 수 있다. 전산 모의 실험을 통하여 동적 다중경로 환경의 도플러 천이에 대한 시스템 수신 성능의 개선을 확인하였다.

  • PDF

Robust Beamforming Method by Linear Array Shape Estimation using Kanlman Filter (칼만필터 선배열 형상 추정에 의한 견실한 빔형성 기법 연구)

  • 한정우
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.18-21
    • /
    • 1996
  • 예인형 선배열 소나에서 기존의 선배열 빔형성 기법을 적용하면 예인함 기동시 선배열 형상 변형에 의해 심각한 성능 저하 현상이 나타난다. 이러한 문제 해결을 위해 센서배열 변형을 고려한 견실한 빔형성 기법은 선배열 형상 추정을 위해 칼만필터를 이용한 형상 추정기법을 이용하고, 변형보상 빔형성을 위해 선배열 세그먼트 기울기 추정값을 이용하는 변형보상 빔형성 알고리즘을 제안하였다. 제안된 기법을 기존의 빔형성 기법을 적용하여 시뮬레이션에 의해 제안된 기법의 보상성능을 입증 하였다.

  • PDF

모듈화된 신형저가 고효율 평판형 태양열 집열기 개발

  • Lee, Dong-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.373-380
    • /
    • 2005
  • 알루미늄 재질의 찬넬을 흡열판으로 이용하는 평판형 태양열 집열기를 개발하였다. 이러한 흡열판은 찬넬 내부 전체로 전열매체가 흐르기 때문에 집열기의 열적성능을 향상시킬 것으로 예상되며, 모듈화되어 있어 제작 및 설치가 기존 흡열판보다 용이하다는 장점이 있다. 제작된 찬넬형 평판형 태양열 집열기에 대한 집열효율 시험을 수차례 수행하면서 성능을 개선시키고 있으며, 그 결과 기존 상용화된 집열기 수준의 우수한 열적성능을 갖는 것으로 나타났다. 알루미늄 재질 흡열판 외에 플라스틱 재질의 찬넬형 흡열판도 적용하였으며, 기타 실용화 및 성능 향상에 필요한 요소들에 대해 연구하였다.

  • PDF

복사열 노출에 따른 소방보호복의 열보호성능 측정

  • Bang, Yeong-Jun;Lee, Jun-Gyeong;Bang, Chang-Hun;Gwon, Jeong-Suk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.78-79
    • /
    • 2013
  • 소방보호복은 화재진압현장에서 소방관들을 화상 위험으로부터 보호하기 위해 가장 많이 착용하는 장비이다. 소방보호복의 열보호 특성을 정확히 파악하고 있어야 소방관들의 화재진압작업시 위험요소를 적절히 판단하여 화상 사고 등을 예방할 수 있다. 따라서 본 연구는 복사열 노출에 따른 소방보호복의 열보호 성능을 정확히 측정 및 분석하기 위해 실험 장비를 제작하고 실험을 수행하였다. 소방 보호복의 구성 재료 각각에 대해 복사열 노출을 시켜 시간에 따른 피복 전후면의 온도차와 통과 열유속을 측정하여 소방 보호복의 열보호 성능 특성을 살펴보았다.

  • PDF