Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열회수성능 분석)

  • 서원명;윤용철;강종국
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.212-222
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. The experimental heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas flue, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amounts by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air tubes and exhaust air passages crossing the tubes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through flue.

  • PDF

Characteristics of boil-off-gas partial re-liquefaction systems in LNG ships (LNG선박용 BOG 부분재액화 시스템 특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.174-179
    • /
    • 2016
  • To protect the ocean environment, the use of liquefied natural gas (LNG) carriers, bunkering ships, and fueled ships is increasing. Recently, Korean shipbuilders have developed and supplied a partial reliquefaction facility for boil-off-gas (BOG). Despite reasonable insulation, heat leakage in vessel storage tanks causes LNG to be continuously evaporated as BOG. This research analyzed the maximum liquid yield rate for various partial reliquefaction systems (PRS) and considered related factors affecting yields. The results showed a liquid yield of 48.7% from an indirect PRS system (heat exchanges between cold flash gas and compressed natural gas), and 41% from a direct PRS system (BOG is mixed with flash gas and discharged from a liquid-vapor separator). The primary factor affecting liquid yield was heat exchanger effectiveness; the exchanger's efficiency and insulation characteristics directly affect the performance of BOG reliquefaction systems.

Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating (선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구)

  • Jang, Sung-Cheol
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.63-68
    • /
    • 2021
  • Domestic electric heater manufacturers are focusing on technology development to improve the efficiency of existing products. The electric heater for ship fuel is large in size and has high difficulty in miniaturization/high efficiency, so there are not many companies that try to develop technology yet. The existing electric heater has a structure of low heating efficiency because the contact time with the heat exchange tube of the heating medium is very short because the flow path of the ship engine fuel is monotonous. Since it is manufactured in a tubular shape, the volume is very large regardless of the heating efficiency. As a result, the tubular electric heater device applied by overseas advanced companies has difficulty in maintaining and repairing because it is necessary to decompose all tubular heaters when a specific part of the inside is damaged and if the heat exchange tube is damaged, all the heat exchange tubes must be decomposed. In this study, a basic study on plate type electric heaters capable of heating 10 tons of ship engine fuel per hour and setting a maximum temperature of up to 150℃ was conducted through a 250kW capacity plate type electric heater.

Design of the Stand-alone Autothermal Reformer for Natural Gas (자체 기동형 천연가스 자열개질기 설계)

  • Koo, Jeongboon;Kim, Youngae;Kwon, Hyunji;Kwak, Inseob;Sin, Jangsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.113.1-113.1
    • /
    • 2010
  • 본 연구에서는 중 소형 SOFC에 적용할 수 있는 연료 변환 시스템으로 자체 기동 및 독립운전이 가능한 천연가스 자열개질(ATR) 반응기를 $10Nm^3/hr$급으로 개발하고자한다. 설계된 천연가스 자열개질기는 자열개질 촉매를 코팅한 금속 모노리스형 촉매체를 반응기 내에 장착함으로써 반응열을 신속하게 제거 또는 공급할 수 있는 시스템으로 구성되었다. 이는 금속 모노리스의 뛰어난 열전도 능력에 의해 반응기 내의 촉매층 전체 온도 분포를 균일하게 유지할 수 있는 저에너지형 자열개질 반응기이다. 또한 빠른 기동 특성을 실현하기 위하여 전기 발열식 촉매체(EHC ; Electically Heated Catalyst)를 장착한 start-up 시스템을 적용하여 천연가스 자열개질 반응기의 신속한 기동과 장치 간편화를 실현하였으며, 합성 syngas의 배열 회수를 위한 최적 열교환 시스템을 설계/적용함으로써 에너지 효율 향상을 도모하였다. 이와 같은 촉매 및 구조 시스템을 가지는 천연가스 자열개질 반응용 소형 연료변환 시스템을 원통형의 이중관 구조로 구성하고, 독립운전 모드로 개발함으로써 소형 SOFC의 연료 변환장치의 적용에 용이하게 하고자 한다.

  • PDF

Drying of Red Ginseng by Flat-Plate Solar Collector (평면식(平面式) 태양열집열기(太陽熱集熱機)를 이용(利用)한 홍삼건조(紅蔘乾燥))

  • Chang, Kyu-Seob;Kim, Sang-Dal;Hong, Soon-Keun;Yoon, Han-Kyo
    • Applied Biological Chemistry
    • /
    • v.25 no.3
    • /
    • pp.111-118
    • /
    • 1982
  • A closed solar collector drying system by water exchange was evaluated for the drying of ginseng. The thermal efficiency of solar collector, drying efficiency, drying characteristics and product quality were investigated. The drying period was reduced by one-thirds in comparison with typical method. The maximum and minimum thermal efficiency of the solar collector during drying period were 14.42%, and 4.73%, respectively. The drying efficiency of solar collector and control system showed 28.34%, and 13.45%, respectively; net drying efficiency being 14.8%. The drying rate curve of red ginseng showed only falling rate period, and its equation was $Y=50.7023t.^{-0.4138}$ The brown color intensity of red ginseng was higher in solar collector drying system than in typical method, and reductivity by diphenyl picryl hydrazil solution in red ginseng extract showed similar result to brown color intensity.

  • PDF

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Separation of enzymen with polymeric membrane (고분자막을 이용한 효소의 분리)

  • 이제권;정용섭;홍석인
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.45-46
    • /
    • 1991
  • 분리막 공정은 상변화를 일으키지 않기 때문에 장치비가 저렴하며, 열 및 화학적으로 민감한 물질, 특히 생체물질 등을 다루는데 적합하다. 또한 최종 생성물질을 정제하는 방법으로는 이온교환 크로마토그래피, 전기 영동 및 친화성 크로마토그래피(affinity chromatography)가 있다. 이중 친화성 크로마토그래피는 가장 선택적이고, 단일 장치로서 기존의 분리방법에 비해 약 1000배 가까이 정제할 수 있다. 본 실험에서는 트립신 억제제인 m-aminobenzamidine을 포함하고 있는 수용성 고분자를 제조하여 트립신을 선택적으로 분리하고자 하였으며, 본 연구 필요한 분리막은 막제조가 용이하며 비용이 저렴한 cellulose acetate막을 사용하였다. CA 막의 세공크기는 겔화매질의 에탄올 농도로 조절하였다. Casting 용액의 조성은 다음 표에 간략하게 나타내었다.

  • PDF

A Study on the Performance of Heat Recovery Ventilators for Apartment Houses (공동주택용 폐열회수형 환기장치의 성능에 관한 측정 연구)

  • Chang, Hyun-Jae;Hong, Seok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.26-34
    • /
    • 2008
  • Heat recovery ventilator(HRV) is recommended to improve indoor air quarlity (IAQ) and energy conservation in apartment houses. Recently, in Korea, HRV is produced from many manufacturers. However, there have been not so many experiences to apply HRV in apartment houses and verification on the performance such as heat exchange efficiency, carry-over rate, internal leakage, etc. have not been carried out sufficiently. So in this study, fan performance, heat exchange efficiency, air leakage, internal exhaust leakage, external leakage and sound level of HRV were examined for selected HRV models under domestic and international standard. Results of performance test, there were need to improve latent heat exchange efficiency and sound level of HRV.

Heat Exchange Drainage Method Induced Bearing Capacity Characteristic (열유도 배수공법이 적용된 지반의 하중지지 특성)

  • Shin, Seung-min;Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.159-164
    • /
    • 2017
  • This paper presents the results of an investigation into the thermo-hydromechanical response of weathered granite soil. The effect of forced change temperature and relative humidity at the soil layer boundaries were monitored during heating. A series of load settlement test were performed on layers of compacted, unsatureated weathered granite soil with geosynthetic embedded at mid height before and after application of heat exchanger to the base of the soil layers. The results from this study indicated the potential for using embedded heat exchangers for the mechanical improvement of geotechnical systems incorporating weathered granite soil.

A Development of Counter Flow Type of Cooling System for Effective Panel Cooling (효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발)

  • Lee, Joong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.802-807
    • /
    • 2010
  • The high efficient and cooling system is very important to the control panels of electrical distributors, and Industrial automated system including computer. Also, it can be used widely in various industrial systems such as industrial robots, numerically controlled machining center, and so on. The cooling method which flowing gasses were forced to circulate by compulsion was adapted in this study. then development of counter flow type of cooling system for effective panel cooling. In the present study, fin assembly was developed for this cooling system. As results, the developed system has the improvements of cooling performances and radiant heat ratio. Its increasing of airflow mass is about 20%, and radiation rate of heating is twice or more as high as the conventional system.