• Title/Summary/Keyword: 열필름 프로브

Search Result 5, Processing Time 0.024 seconds

Velocity Field Measurements Over A Lex/Delta Wing By Triple Axis Hot-Film Anemometry (3축 HOT-FILM 풍속계에 의한 연장된 앞전을 갖는 삼각날개 속도장의 측정)

  • Lee,Gi-Yeong;Son,Myeong-Hwan;Jang,Yeong-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.1-8
    • /
    • 2003
  • Velocity data were acquired at a series of stations in the chordwise direction above a delta wing with leading edge extension, using a triple axis hot film anemometry. Surveys normal to planform yield velocity field data at incidence angle of 24$^{\circ}$and 32$^{\circ}$at a centerline chord Reynolds number of $1.76{\times}10^6$. Experimental results of velocity measurements of mean velocity of three components gave a confidence to quantitative investigate the vortical flow field over a LEX-delta wing with this probe. The present experiments indicated the existence of both wing and LEX vortex where the local mean axial velocity is maximum. It also shown the development of secondary vortex of opposite sign of rotating above the wing surface near the leading edge. The insertion of probe across the flow field was found to have little influence on the position of the vortex core.

형태변환형 투명 전극에 적용 가능한 그래핀-ITO 적층 필름 형성 및 특성 평가에 관한 연구

  • Kim, Jang-A;Kulkarni, Atul;Hwang, Tae-Hyeon;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.199-199
    • /
    • 2012
  • 최근 그래핀의 대면적 합성 및 롤투롤 전사 공정의 개발로 그래핀의 상용화가 가시화 되고 있다. 하지만, 그래핀의 독특한 특성인 선형적이고 밴드갭이 없는 에너지 띠 분포 때문에 반도체 소자로서의 직접적인 적용에는 한계가 있다. 이러한 문제를 해결하기 위한 돌파구로써, 그래핀 복합체의 연구와 개발이 활발히 진행되고 있으며 본 연구에서는 그래핀 복합 적층 구조를 다룬다. 이는 디스플레이, 초고속 반도체 소자, 고성능 광전자소자 및 초고감도 센서 등 다양한 분야에 대한 그래핀의 실용화 가능성이 높아진 것을 의미한다. 특히, 높은 가시광 투과도와 낮은 면저항으로 기존 투명 전극에 대표적으로 사용되고 있는 ITO (Indium Tin Oxide)를 그래핀으로 대체하는 것에 관한 연구가 활발히 진행되고 있다. 하지만 그래핀이 높은 전자이동도를 가지는 것에 비하여 비저항과 투과도 측면에 있어서는 ITO의 성능을 뛰어넘지 못하는 실정이다. 따라서 본 연구에서는 ITO가 가지는 취약점인 기판과의 약한 접착력, 높은 취성, 기판과의 열팽창률 차이 등의 공정상 문제점을 극복하고자 하였다. 그래핀 복합 적층 필름은 플라스틱 기판 (PET) 위에 열 화학기상증착법(Chemical Vapor Deposition, CVD)을 이용하여 합성한 그래핀을 전사하고, ITO 용액을 도포한 다음 다시 그래핀을 씌워 제작하여 샌드위치 구조(sandwich structure)를 형성하였다. 완성된 필름은 광학적, 전기적 특성 분석을 수행하였다. 광학적 분석으로는 라만 분광을 이용한 그래핀 품질평가와 파장대에 따른 광 투과도, 그리고 반사도 측정을 하였으며, 전기적 특성은 면저항을 측정함으로써 분석한다. 결함이 적고, 대면적에 걸쳐 한 층을 이루어야 하는 고품질 그래핀의 요구사항에 따라 라만 분광의 G, 2D, D 띠를 분석하였다. G와 2D 띠의 비율을 통해 그래핀의 층 수를, D 띠의 강도를 통해 결함의 유무를 판단하였다. 또한, 가시광 영역에서 90% 이상의 광 투과도를 보여야 하는 투명 소자의 요구사항 달성 정도를 UV-VIS를 이용하여 확인하였다. 마지막으로, 제작한 필름의 면저항 또한 4-프로브 멀티미터를 이용하여 측정하고, 일반적인 터치스크린의 면저항인 $500{\Omega}/sq$를 만족하는지 평가하였다.

  • PDF

Flow characteristics at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동 특성)

  • Hong, Soon-Sam;Kang, Shin-Hyoulg
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.36-44
    • /
    • 2000
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A hot-film probe and a high response pressure transducer are used to investigate the flow at impeller exit and vaneless diffuser region for design and off design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, design, and numerical analysis of pumps.

  • PDF

Investigation on the Improvement of Computer Aided Calibration Methods for Hot-Wire and Hot Film Probes (컴퓨터원용 열선 및 열필름 프로브의 교정방법 개선에 대한 연구)

  • 김경천;윤순현;신영호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.977-985
    • /
    • 1994
  • New computer-aided calibration methods for the hot-wire and split film probes are presented. The proposed modified king's law takes into account instantaneous flow angle as well as the variation of calibration coefficients due to the total velocity magnitude change. It is found that the look-up table method has many advantages with respect to the accuracy on data and reducing run time for calibration over other conventional methods. In order to investigate the local sensitivity of the static calibration, a dynamic calibration procedure is also carried out.

An Experiment on the Effects of Free Stream Turbulence Intensity on the Backward-Facing Step Flow (자유흐름 난류강도가 후향계단유동에 미치는 영향에 대한 실험)

  • 김사량;유정열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2297-2307
    • /
    • 1995
  • An experimental study on the structure of a separated shear layer downstream of the backward-facing step has been performed by examining mean flow and turbulent quantities in terms of free stream turbulence. When free stream turbulence exists, the entrainment rate of the separated shear layer and the flow rate in the recirculation region are enhanced, resulting in shorter reattachment length. The production and diffusion terms in the turbulent kinetic energy balance are shown to increase more than the dissipation term does. Rapid decrease of the pressure-strain term in the shear stress balance implies the enhancement of the three-dimensional motion by free stream turbulence.