• Title/Summary/Keyword: 열펌프 시스템 설계

Search Result 7, Processing Time 0.139 seconds

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Dynamic Behavior Simulation of Reactor for Chemical Heat Pump System Design (화학 열펌프 시스템 설계를 위한 반응기의 동적 거동 모사)

  • 김태민;김성준;최홍규;이태희
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.43-47
    • /
    • 1994
  • 화학 열펌프 시스템의 반응기 설계를 위하여 정적 설계의 결과를 이용하여 시간에 따른 전화율, 온도, 압력, 출력 등의 변화에 대한 모사를 시도하였다. 정적 모사를 통한 설계결과는 동적 거동 모사의 결과와 유사하였으며, 이로부터 정적모사가 동적모사를 위한 적절한 초기치와 기초 설계 정보를 제공함을 알 수 있었다. 본 연구를 통하여 확립된 설계절차와 해석방법에 따른 사례연구를 통하여 향후 실용화될 화학 열펌프 시스템의 개략적인 사양과 바람직한 설계방향을 제시 할 수 있었으며, 반응기의 조작에 따른 제어변수의 영향을 평가하는 기준을 마련할 수 있었다.

  • PDF

GSHP System Development and Dissemination Issues (지열원 열펌프 시스템 개발 및 보급 활성화 개선방안)

  • Lee, Euy-Joon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.202-205
    • /
    • 2006
  • 최근 지열원 열펌프 시스템 설치가 해마다 평균 10-30%젓도 꾸주히 증가하고 있다 주요 연구동향은 토양열전도 측정, 지열히트펌프 시스템 전주기 성능평가 하이브리드 시스템의 초기비용 저감과 이러한 지열원 열펌프 시스템 설계방법분야 개발에 대해 초점이 맞춰지고 있다. 특히 국내에서 현재 시공되어진 많은 시스템들이 부실시공의 문제에 노출되고 있으며 이러한 시점에서 현재의 저가 입찰제도 보다는 외국 사례와 같은 성능확인 제도로의 전환 및 많은 연구가 필요하다. 성능확인제도는 사전 성능 예측과 사후 성능 확인 검증으로 구성되며 본 기술현안 보고서는 최근 국내외 연구동향 및 사전 성능 예측과 사후 성능 검증 관하여 정리하여 본다.

  • PDF

Status of GSHP System Development (지열원 열펌프 시스템 기술 연구 현황 및 현안)

  • Lee, Euy-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1238-1243
    • /
    • 2006
  • 최근 열펌프 시스템 설치가 해마다 평균 10-30% 정도 꾸준히 증가하고 있다. IEA HP Annex 28, 29('열펌프 성능평가 기술', '열펌프 시장 현황 현안')등 국제공동연구를 통한 꾸준한 지열원 열펌프 시스템 응용분야의 발전은 기존의 지열원 시스템에 비해 비용과 더불어 보다 많은 에너지 절감효과를 가져왔다. 지열기술의 성공적 사용여부는 기술의 견실함, 설계기술의 개발, 기반시설설치, 히트펌프와 부품제조업자의 반응에 기인한다. 최근 주요 연구동향은 토양열전도 측정, 지열히트펌프 시스템 전주기 성능평가, 하이브리드 시스템의 초기비용 절감과 이러한 열펌프 시스템 설계방법분야 개발에 대해 초점이 맞춰지고 있다. 본 기술현안 보고서는 최근 국내외 연구동향을 정리하여 본다.

  • PDF

Study on Design Technology of Heat Pump Cycle for High Temperature Performance (고온 생산용 열펌프 사이클 설계)

  • Kim, Jong-Ryul;Kim, Seok-Young;Kim, Yong-Min;Lee, Kong-Hoon;Kim, Ook-Joong;Yi, Sung-Chul;Jung, Chi-Young;Kim, Jong-Ryeol
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.228-233
    • /
    • 2010
  • About 55% of total energy is consumed in the industrial division. The industrial heat pump application will show magnificent energy saving effect as well as higher cost efficiency because of larger energy consuming volume of each facility and longer operation hour and higher stability against seasonal temperature change. Over 90% of dryer for industrial usage has hot wind heat source and hot wind dryer is the representative type covering 68.7% while its 30 ~ 50% lower heat efficiency causes lots of energy loss by exhaust air. Re-usage of exhaust air can improve energy efficiency of dryer because 68% heat energy or 78% of hot air lose in exhaust air. Therefore, high temperature heat pump dryer can be the best alternative. Comparing to the existing dryer with 30% ~ 50% energy efficiency, newly developing high temperature heat pump dryer will enhance energy efficiency up to 60% ~ 80% efficiency. In this paper, heat pump system for high temperature was designed, constructed and tested. The results have shown that system COPh is estimated as 3.3.

Performance analysis of dual source heat pump system with single unit dual source evaporator (SUDS증발기를 사용한 2중열원 열펌프의 성능해석)

  • 우정선;이세균;이재효;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

생활폐열회수를 위한 열교환기 개발 중심 폐열회수 고효율 난방 시스템

  • 신현준;이태원
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.65-73
    • /
    • 1994
  • 도시생활폐수에 포함되어 배출되는 폐열을 열펌프의 열원으로 하는 폐수열원 열펌프 시스템에 대한 관심이 오래전부터 집중되어 있었지만 폐수 열교환기 전열면의 오염문제 때문에 실용화에 커다란 진전을 보지 못하고 있다. 한편, 생활페수는 비교적 저온이기 때문에 열펌프시스템의 설계에 특별한 주의를 기울여야 한다. 즉, 이러한 폐열을 회수하여 유효에너지 자원화 하기 위한 신기술이 이루어 져야한다. 본 연구에서는 이러한 점을 감안하여 도시생활 폐수열의 이용가능성을 검토하고 이를 열원으로 하는 열펌프의 개발을 위한 폐수 열교환기의 모델을 개발하였다.

  • PDF