• Title/Summary/Keyword: 열전도 패드

Search Result 18, Processing Time 0.023 seconds

COG(chip-on-glass) Mounting Using a Laser Beam Transmitting a Glass Substrate (유리 기판을 투과하는 레이저 빔을 사용한 COG(chip-on-glass) 마운팅 공정)

  • 이종현;문종태;김원용;김용석
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.4
    • /
    • pp.1-10
    • /
    • 2001
  • Chip-on-glass(COG) mounting of area array electronic packages was attempted by heating the rear surface of a contact pad film deposited on a glass substrate. The pads consisted of an adhesion (i.e. Cr or Ti) and a top coating layer(i.e. Ni or Cu) were healed by the UV laser beam transmitted through the glass substrate. The lather energy absorbed on the pad raised the temperature of a solder ball which is in physical contact with the pad, and formed a reflowed solder bump. The effects of the adhesion and top coating layer on the laser reflow soldering were studied by measuring temperature profile of the ball during the laser heating process. The results were discussed based on the measurement of reflectivity of the adhesion layer. In addition, the microstructures of solder bumps and their mechanical properties were examined.

  • PDF

Three-Dimensional Beat Transfer Analysis on Tilting-Pad Thrust Bearings (3차원 열전달을 고려한 틸팅패드 스러스트 베어링의 해석)

  • Kim Ho-Jong;Choi Sung-Pil;Ha Hyun-Chun
    • Tribology and Lubricants
    • /
    • v.22 no.4
    • /
    • pp.173-181
    • /
    • 2006
  • In the present study, we developed a numerical analysis software to predict performance of tilting-pad thrust bearings. The finite element method was adopted to compute lubricant film pressure and temperature. Three-dimensional heat transfer equations were solved simultaneously for the lubricant film, pad, and runner. Groove temperature was assumed with two different models. From application of the software to a thrust bearing, it has been seen that the three-dimensional analysis predicts higher temperature than the average temperature analysis. It has also been found that the groove model with a hot-oil-carry-over factor predicts higher temperature.

The Distribution of Temperature on Pad Surface During CMP Process (CMP 공정중 패드 표면의 온도분포에 관한 연구)

  • Jeong, Young-Seok;Kim, Hyoung-Jae;Jeong, Hae-Do
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1283-1288
    • /
    • 2003
  • The friction heat generated by the CMP process hasinfluence on removal rate and WIWNU(Within Wafer Non-Uniformity). Therefore, the object of this study is to find the distribution of temperature on pad surface during CMP process. To do this, the authors analyse the kinematics of CMP equipment to verify the sources of friction heat and compare the analysis result with the experimental results. Through the analysis and experiment conducted in this paper, we can predict the distribution of polishing temperature across the pad surface. Furthermore the result could help to predict the process conditions which could enhance the polishing results, such as WIWNU and removal rate of thin film to achieve more efficient process.

  • PDF

A Study on the Thermal Behavior Characteristic of Drum Brake considering Braking Patterns (제동 패턴을 고려한 드럼 브레이크의 열적 거동 특성에 대한 연구)

  • Lee, Kye-Sub;Son, Sung-Soo;Yang, Ki-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.145-154
    • /
    • 2006
  • Each part of drum brake system is loaded by continual mechanical force and thermal force every time of braking, so enough strength and stability are required. Thermal characteristic is one of the important factors in drum brake systems design. This paper presents the thermal performance such as temperature distribution and thermal contact stress of drum brake system considering several braking patterns; 80th heat braking test mode, heat fade braking test mode, general road mode, steep slope road mode and off road mode. Transient heat transfer analysis and Thermo elastic contact analysis is executed to obtain the temperature distribution, and to evaluate thermal stress of drum brake by using ABAQUS/Standard code. This procedure of analysis can effectively be used to improve the quality problem of brake system and to get design guideline of the new product.

Analysis of Integration Factor Effect in Dynamic-Structure-Fluid-Heat Coupled Time Transient Staggered Integration Scheme for Morton Effect Analysis (모튼이펙트 해석을 위한 동역학-구조-유체-열전달 시간과도응답 연성해석 시차적분법에서 시상수 효과 분석)

  • Suh, Junho;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The present study focuses on the effect of staggered integration factor (SIF) on Morton effect simulation results. The Morton effect is a synchronous rotordynamic instability problem caused by the temperature differential across the journal in fluid film bearings. Convection and conduction of heat in the thin film displaces the hot spot, which is the hottest circumferential position in the thin film, from -20 to 40 degrees ahead of the high spot, where the minimum film clearance is experienced. The temperature differential across the journal causes a bending moment and the corresponding thermal bow in the rotating frame acts like a distributed synchronous excitation in the fixed frame. This thermal bow may cause increased vibrations and continued growth of the synchronous orbit into a limit cycle. The SIF is developed assuming that the response of the rotor-lubricant-bearing dynamic system is much quicker than that of the bearing-journal thermal system, and it is defined as the ratio between the simulation time of the thermal system and the rotor-spinning period. The use of the SIF is unavoidable for efficient computing. The value of the SIF is chosen empirically by the software users as a value between 100 and 400. However, the effect of the SIF on Morton effect simulation results has not been investigated. This research produces simulation results with different values of SIF.

Study of the ENC reduction for mobile platform (모바일 플랫폼을 위한 전자해도 소형화 연구)

  • 심우성;박재민;서상현
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.181-186
    • /
    • 2003
  • The satellite navigation system is widely used for identifying a user's position regardless of weather or geographic conditions and also make effect on new technology of marine LBS(Location Based Service), which has the technology of geographic information such as the ENC. Generally, there are conceivable systems of marine LBS such as ECDIS, or ECS that use the ENC itself with powerful processor in installed type on ships bridge. Since the ENC is relatively heavy structure with dummy format for data transfer between different systems, we should reduce the ENC to small and compact size in order to use it in mobile platform. In this paper, we assumed that the mobile system like PDA, or Webpad can be used for small capability of mobile platform. However, the ENC should be updated periodically by update profile data produced by HO. If we would reduce the ENC without a consideration of update, we could not get newly updated data furthermore. As summary, we studied considerations for ENC reduction with update capability. It will make the ENC be useful in many mobile platforms for various applications.

  • PDF

The Development of the Smart Sensibility Mat with Kangaroo Mother Care (캥거루 케어를 반영한 스마트 감성 매트의 개발)

  • Cho, Soo-Min
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • 'Smart Sensibility Mat (SSM)' was developed and manufactured for positive sensibility of newborn with fiber, digital, and sensibility technology to reflect features and advantages of kangaroo care. For tactile stimuli, the tube of the silicon material to provide a constant temperature of $32^{\circ}C$ was inserted into the mat and connected to the water-thermostat. To provide a uniform temperature throughout the mat, the fabric by the inserting conductive yarn was attached to the mat surface. After wrapping the mat with cotton pad, the polyurethane foam used as medicine in order to similar to the human skin was bonded to the surface of the mat. To provide the auditory stimuli of a level of 30dB with mother's heartbeat sounds and voice recorded in advance, the Bluetooth speaker was inserted into the mat. To investigate the effects of SSM, 10 newborns who born within two weeks were involved in this experiment. While the baby was lying on each of the general mat (GM) and SSM, the baby's physiological signals-heart rate, breathing rate, temperature- were measured and then, those were conducted t-test to examine the difference between the signals of SSM and GM. The results were as follows: heart rate (t=8.131, p<.001) and respiratory rate (t=7.227, p<.001) among the physiological signals of SSM decreased significantly than GM within the normal range. Temperature (t=1.062, p=0.292) at SSM showed a tendency to decrease than GM within the normal range. This means the tactile stimuli and the auditory stimuli providing from SSM give stable physiological responses. Thus, SSM leads to have psychological comfort and stability of newborns.

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF