• Title/Summary/Keyword: 열전달 모형

Search Result 62, Processing Time 0.027 seconds

소디움 관-통 형 열교환기의 교차류 열전달 해석 특성

  • 심윤섭;김연식
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.298-303
    • /
    • 1996
  • 액체금속로 IHX 의 열전달 해석모형을 개발하기 위한 일차적인 단계로서 교차류 열전달 모형특성에 대한 연구를 수행하였는 그 주요내용은 새로운 대수화 (finite differencing) 기법인 경계점 기법의 특성을 분석하여 이기법의 적절성을 확인하고 IHX 기하형태 및 운전 요건에 따른 격자수에 대한 요건을 분석하고 이로부터 IHX 해석에 간이 이차원 해석 모형 사용의 타당성을 확인하였다.

  • PDF

열량계 채널에 대한 3차원 열전달 해석

  • Park, Tae-Seon;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.142-150
    • /
    • 2003
  • Turbulent flows and related heat transfer in a square heated duct is investigated by a turbulence model and a large eddy simulation. The cooling channel of calorimeter is modeled to the square duct. The nonlinear k-ε-fμ model of Park et al. [3] is slightly modified and their explicit heat flux model is employed. The Reynolds number is varied in the range 4000≤Reb≤20000. The heat transfer is closely linked to the secondary flows which driven by the turbulent motion. Its magnitude is 1~3% of the mean streamwise velocity. The relation of Nu~Re0.8Pr0.34 is validated by comparing with the predicted Nu of k-ε-fμ model. Finally, the coherent structures and thermal fluctuations are scrutinized.

  • PDF

A Study on Thermal Conduction in Oyster Shell Incorporating Gypsum Objects (굴패각 배합 석고재료의 열전도 특성 연구)

  • Kwon, Sung-Hyun;Cho, Daechul
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • We investigated one-dimensional thermal conduction for gypsum objects incorporating oyster shell powder. We presumed that according to the portion of oyster shell in the hybrid structure conductive characteristics of that would also change as some physicochemical properties such as volatile organic compound (VOC) adsorption were found to be changed considerably. Based on Fourier's 2nd law of heat conduction an analytical analysis in a flat slab (one axis perpendicular to an infinite plane) was performed. We found that composition of oyster shell and conduction-related coefficients and parameters could greatly influence on the thermal profile of that conduction, and some model experiments also served for it in the affirmative.

Characteristics of Evaporation Heat Transfer in a Small-Scale Cryogenic Heat Exchange System for the Utilization of LNG Cold Energy (LNG 냉열활용을 위한 초저온 열교환시스템의 축소모형에서 증발 열전달 특성)

  • Nam S. C.;Lee S. C.;Lee Y. W.;Sohn Y. S.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.25-33
    • /
    • 1998
  • The characteristics of evaporation heat transfer for the utilization of LNG cold energy was investigated experimentally using liquified nitrogen and a solution of ethylene-glycol and water under horizontal two-phase conditions in the small-scale equipment of a cryogenic heat exchange system. The inner tubes in the double pipe heat exchanger with 8 mm and 15 mm inner diameter and 6 m length were adopted as a smooth test tubes and enhanced tubes by means of wire-coil inserts. Heat transfer coefficients and Nusselt number for the test tube were calculated from measurements of temperatures, flowrates and pressures. The correlations in a power-law relationship of the Nusselt number, the Reynolds number and Prandtl number for heat transfer were proposed which can be available for design of cryogenic heat exchangers. The correlations showed heat transfer coefficients for the wire-coil inserts were much higher than those for the smooth tubes, increased by more than 2.5 ${\~}$ 5.5 times depending upon the equivalent Reynolds number. Form and length of cryogenic double pipe heat exchanger were proposed for applicable to the utilization of LNG cold energy.

  • PDF

A Non-linear Low-Reynolds-Number Heat Transfer Model for Turbulent Separated and Reattaching Flows (난류박리 및 재부착 유동에 대한 저레이놀즈수 비선형 열전달 모형의 개발)

  • Rhee, Gwang-Hoon;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.316-323
    • /
    • 2000
  • A nonlinear low-Reynolds-number heat transfer model is developed to predict turbulent flow and heat transfer in separated and reattaching flows. The $k-{\varepsilon}-f_{\mu}$ model of Park and Sung (1997) is extended to a nonlinear formulation, based on the nonlinear model of Gatski and Speziale (1993). The limiting near-wall behavior is resolved by solving the $f_{\mu}$ elliptic relaxation equation. An improved explicit algebraic heat transfer model is proposed, which is achieved by applying a matrix inversion. The scalar heat fluxes are not aligned with the mean temperature gradients in separated and reattaching flows; a full diffusivity tensor model is required. The near-wall asymptotic behavior is incorporated into the $f_{\lambda}$ function in conjunction with the $f_{\mu}$ elliptic relaxation equation. Predictions of the present model are cross-checked with existing measurements and DNS data. The model preformance is shown to be satisfactory.

Review of Calculational Model for the Performance of CANDU-Type Nuclear Development and Parametric Study on the Fuel Performance (CANDU형 핵연료거동에 관한 계산모형의 검토 및 거동특성에 관한 변수적 연구)

  • Man Sung Yim;Un Chul Lee;Ho Chun Suk
    • Nuclear Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.57-69
    • /
    • 1983
  • The LWR fuel performance analysis computer code, FRAPCON-1, are evaluated to investigate the performance of CANDU fuel elements loaded in Wolsung-1 reactor. The FRAPCON-1 models of neutron flux depression in fuel and of fuel-to-cladding heat transfer are modified, and the validity of fission gas release model for CANDU fuel is evaluated. And the heavy water properties are provided in calculating the heat transfer coefficient between cladding and coolant. By using the modified code, FRAPCON-1-CSK, the sensitivity studies are carried out for Wolsung-1 fuel element design parameters. The performance analysis is also performed for Wolsung-l fuel elements. The calculated results are discussed in terms of. LWR fuel design criteria because of unavailability of CANDU fuel design criteria.

  • PDF

Heat Transfer Module for Multi-Burner Water Tube Boiler: 0.5 t/h Class Model Simulation (다중버너 수관식 보일러를 위한 전열모듈의 열전달 특성: 0.5 t/h급 모형 수치해석)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.528-533
    • /
    • 2007
  • A finned tube type heat transfer module has been proposed for a multi-burner water tube boiler. Fins change their geometry along the streamwise direction to maximize the performance, which makes it difficult to apply conventional bulk analysis. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also performed to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, where the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.

  • PDF

Mechanisms, Experimental Results, Empirical Correlations and Analytic Models of Beat Transfer in Containment Building Following a LOCA (냉각재 상실 사고시 격납 용기내에 있어서의 열전달에 관한 기구, 실험결과, 선험 관계식 및 해석적 모형들에 관한 고찰)

  • Jong Ho Choi;Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.123-134
    • /
    • 1983
  • Estimates of the rate of heat removal from the containment atmosphere following a loss of colant accident (LOCA) are important to the prediction of containment peak pressure and temperature which are essential parameters in designing the containment building. An overall survey and discussion of mechanisms, experimental results, empirical correlations and analytical models that are relevant to the heat transfer inside the containment have been made. As a result of this review, the current state of the knowledge about tile containment heat transfer can be understood and it is known that more investigations are needed to avoid the misuse of various correlations.

  • PDF

액체금속로 피동 원자로용기냉각계통의 특성 분석

  • 위명환;심윤섭
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.374-378
    • /
    • 1996
  • 피동 원자로용기 냉각계통은 원자로 용기를 둘러싸고 있는 격납공기 외부가 공기에 자연순환에 의해 냉각하는 방식으로 공기 흐름 구동력은 원자로용기의 외부 유로의 공기와 주변 대기와의 밀도 차이에 의하여 피동적으로 형성됨에 따라 높은 작동 신뢰성이 보장된 개념으로서 본 연구에서는 공기입구 위치에 따른 영향 및 격납용기와 유로 벽면간의 복사 효과 까지를 고려 할 수 있도록 해석 모형을 개선 시키고 개선된 모형을 이용하여 계통을 구성하는 설계인자들이 계통의 성능 및 크기에 미치는 영향등을 분석하였다. 이러한 분석을 통하여 공기의 입구 위치가 계통의 열제거용량에 미치는 영향, 상향공기 유로에서의 복사 열전달 고려 유무가 해석 결과에 미치는 영향 그리고 설계인자와 계통 성능간의 상관성을 밝혔다.

  • PDF

Heat Transfer Characteristics of the Asphalt pavement by Solar Energy accumulation (열에너지 누적에 따른 아스팔트 포장의 열전달 특성 변화)

  • Lee, Kwan-Ho;Kim, Seong-Kyum;Oh, Seung-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.490-497
    • /
    • 2020
  • Asphalt pavement accounts for more than 90% of the total pavement in Korea. Pavement is most widely constructed among construction structures. The heat transfer characteristics (Thermophysical Properties) of the asphalt pavement cause the heat island effect in downtown areas. An increasing asphalt surface temperature is one of the major causes of damage to asphalt pavement. This study examined the heat transfer characteristic factors according to solar energy accumulation in an asphalt mixture. The specimens (WC-2 & PA-13, Recycled aggregate used WC-2) used in the experiment were compacted with a Gyratory Compactor. The thermo-physical properties (thermal conductivity, specific heat capacity, thermal diffusivity, and thermal emissivity) and solar energy accumulation were evaluated. The thermal accumulation and HFM tests revealed a 1.2- to 2.0-fold difference. This indicates that the thermal conductivity of the asphalt mixture pavement changes with the accumulation of solar energy. An analysis of the correlation of thermal conductivity according to the surface temperature of the asphalt mixture showed that WC-2 was logarithmic, and PA-13 was linear. Experiments on the heat transfer characteristics of asphalt pavement that can be used for thermal failure modeling of asphalt were conducted.