• Title/Summary/Keyword: 열전달률

Search Result 54, Processing Time 0.026 seconds

Experimental Study on the Heat Transfer and Turbulent Flow Characteristics of Jet Impinging the Non-isothermal Heating Plate (비균일 온도분포를 갖는 평판에 대한 충돌제트의 열전달 및 난류유동특성에 관한 연구)

  • 한충호;이계복;이충구;이창우
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.272-277
    • /
    • 2001
  • An experimental study of jet impinging the non-isothermal heating surface with linear temperature gradient is conducted with the presentation of the turbulent flow characteristics and the heat transfer rate, represented by the Nusselt number. The jet Reynolds number ranges from 15,000 to 30,000, the temperature gradient of the plate is 2~4.2$^{\circ}C$/cm and the dimensionless nozzle to plate distance (H/D) is from 2 to 10. The results show that the peak of heat transfer rate occurs at the stagnation point, and the heat transfer rate decreases as the radial distance from the stagnation point increases. A remarkable feature of the heat transfer rate is the existence of the second peak. This is due to the turbulent development of the wall jet. Maximum heat transfer rate occurs when the axial distance from the nozzle to nozzle diameter (H/D) is 6 or 8. The heat transfer rate can be correlated as a power function of Prandtl number, Reynolds number, the dimensionless nozzle to plate distance (H/D) and temperature gradient (dT/dr). It has been found that the heat transfer rate increases with increasing turbulent intensity. The wall jet is influenced by temperature gradient and the effect becomes more important at higher radii.

  • PDF

Asymptotic Approach to Pressure Drop and Heat Transfer in a Rectangular Pipe with Shear-thickening Fluids (사각형 단면 파이프 내에서의 Shear-thickening 유체를 이용한 압력강하 및 열전달 예측에 대한 점근적 해석)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.23-30
    • /
    • 2011
  • 본 연구는 산업용 열교환기 및 상용 파이프의 최적 설계를 위하여 열교환기 내의 사각형 단면 파이프의 shear-thickening 비뉴톤 유체의 압력강하 및 대류 열전달률을 수치해석적으로 수행하였다. shear-thickening 유체의 구성 방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 확장 멱법칙 모델을 채택하였다. 파이프 내의 압력강하를 의미하는 마찰계수와 확장 레이놀즈 수의 곱은 기존 연구의 비교자료와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.018% 및 0.06% 내에서 일치함을 보였고, 대류 열전달률을 의미하는 뉴셀트 수는 문헌치와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.025% 및 0.14% 내에서 일치함을 보였다. 비뉴톤 확장 멱법칙 유체 모델의 형태를 띠는 shear-thickening 유체를 열교환기 또는 상용파이프 내의 사각형 단면 파이프 내에서 사용하면 유동지수(n)에 따라서 뉴톤 유체보다 최대 160%의 압력강하를 증가시켰고 최대 14%의 대류 열전달 감소를 발생시킬 수 있었다.

Flow and Heat Transfer with Mesh in Direct Contact Liquid-Liquid Heat Exchanger for Solar Thermal System (태양열원을 위한 직접접촉식 액-액 열고환기에서 메쉬설치에 따른 유동 및 열전달)

  • 윤석만;김정보
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.28-36
    • /
    • 2000
  • 태양열 시스템에 사용되는 간접접촉을 열교환기는 열전달률감소, 부식, 스케일링 등의 문제에 기인하는 단점을 갖고 있다. 이러한 문제들을 해결하기 위하여 직접접촉 열교환기의 사용이 제안된다. 본 연구에서는 직접접촉 열교환기로서 분사칼럼이 도입되었다. 열전달률을 증가기키기위하여 작동유체는 연속유체와의 접촉면적을 증가시키기위하여 칼럼내에서 작고 균일한 방울들로 분산된다. 또한 작고 균일한 방울들로 만들기 위하여 열교환기 칼럼내에서 메쉬가 설치되었다. 디에틸 프탈레이트(Diethyl Pthalate , 밀도 : 1,052g/㎤)가 작동유체로 사용되었고, 메쉬가 있는 경우와 없는 경우로 비교 실험되었다. 실험중 칼럼의 길이방향으로 온도측정을 하였고, 두 유체간의 직접접촉 열교환 메카니즘을 알기 위하여 방울의 사진을 통하여 분석하였다. 방울이 제트형태로 형성될 때 방울은 작고 균일하였다. 한편 방울형태로 형성될 때는 크고 불균일하게 관찰되었으나 , 메쉬를 통해 칼럼내에서 효과적으로 작고 균일한 방울들로 되었다.

  • PDF

Numerical Analysis of Fluid Flow in a Regenerative Cooling Passage (재생냉각 유로 내의 유동에 관한 수치해석)

  • 조원국
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2000
  • A computational analysis has been made on fluid flow in a regenerative cooling Passage for a reduced size liquid rocket engine to predict pressure drop and heat transfer rate in it. The contraction/expansion of the cross sectional area of the passage turn out to increases both the pressure loss and the heat transfer rate of the duct. The changes of the cross sectional area near the nozzle throat are effective to protect the throat which suffers from severe thermal load. Also given is the qualitative characteristics of the performance of the regenerative cooling system due to the variation of coolant flow rate.

  • PDF

Analysis of Characteristics on Small Air Conditioning Type Condenser (소형 공조용 응축기의 특성 해석)

  • 김재돌;장재은;윤정인
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • 본 연구는 일반적으로 소·중용량의 냉동·공조기에 많이 사용되고 있는 플레이트 핀 코일형 공냉응축기를 대상으로 수치해석에 의해 응축기의 특성을 파악하였다. 해석에서는 응축기를 과열증기영역, 2상영역 및 과냉각액영역으로 구분하여 공냉 응축기의 성능에 큰 영향을 미치고 있는 공기온도, 공기측열전달률, 입구 냉매온도, 응축온도 및 질량유량 등을 파라메터로하여 이들의 상호관계와 이들이 응축완료점까지의 거리 및 방열량 등에 미치는 영향을 파악하였다. 해석결과로는 해석모델로부터 각 영역의 냉매 상태량, 온도분포 및 열전달률을 구할 수 있었고, 일반적으로 응축기의 성능에 많은 영향을 미치는 각종 파라메터들을 중심으로 광범위한 동작조건에서 이들의 상관관계 및 특성을 파악하므로서 응축기 설계를 위한 기초 자료 및 설치장소나 주위환경 등에 따라 서로간에 다양한 영향을 미치는 실제장치의 동적특성 해석을 위한 자료를 얻을 수 있었다.

  • PDF

Classification and Applications of Direct Contact Condensation Heat Exchanger (직접접촉응축 열교환기의 분류 및 응용)

  • 오후규;김성규
    • Journal of the KSME
    • /
    • v.35 no.7
    • /
    • pp.638-646
    • /
    • 1995
  • 직접접촉 얼교환 기술은 냉각탑, 접촉급수 가열기 및 공기분리기 등과 같은 장치에 예전부터 이용되어 왔는데, 그 주요한 적용이유는 가열유체와 수열유체의 사이에 일어나는 전열이 일반 열교환기와는 달리 고체벽(금속 열전달표면)을 통과하지 않고 열교환을 함으로써, 종래의 열교 환기에 비하여 상대적으로 설비의 간단화, 부식 및 스케일 부착문제가 경감됨에 따른 적은 유 지보수비 및 높은 열전달률을 얻을수 있는 이점이 있으며, 저 온도차에서의 효율적인 사용이 가능하기 때문이다. 이 글에서는 직접접촉응축 현상의 장점을 이용하는 직접접촉식 교환기의 구조와 형태, 그리고 그 응용분야에 대해서 알아보고자 한다.

  • PDF

Effects of Baffle Structure Variation on Heat Transfer Performance in a Shell-Tube Heat Exchanger (배플 구조변경이 Shell-Tube 열교환기의 열전달성능에 미치는 영향)

  • Hou, Rong-Rong;Cho, Joeng-Kwon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3014-3021
    • /
    • 2015
  • Shell-tube heat exchanger is widely applied in industrial field by easily manufacturing as to various size and flow patterns. In this study, by changing baffle's cut direction, tilt angle and rotational angle as well as by using SST (Shear Stress Transport) $k-{\omega}$ turbulence model in ANSYS FLUENT v.14, the heat transfer rate and pressure drop characteristics of inner shell will be analyzed to improve heat transfer ability. As a result of analysis, heat transfer performance according to cut direction of baffle has been improved with vertical model B and angle $45^{\circ}$ model C than horizontal model A. In addition, the tilt $10^{\circ}$ of the baffle and rotational angle $0^{\circ}-90^{\circ}-180^{\circ}-270^{\circ}$ of model D showed better result in heat transfer rate and pressure drop.

Enhancement of Performance of Shell and Tube Heat Exchanger Using Pertinent Leakage Flow Between Baffle and Tube Bundles (배플과 관군간의 적정 누설유동을 이용한 쉘-관 열교환기의 성능향상)

  • Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.223-229
    • /
    • 2015
  • In this study, the effects of the leakage flow between the baffle and tube bundles on the performance of a shell and tube heat exchanger (STHE) were examined using the commercial software ANSYS FLUENT v.14. A computational fluid dynamics model was developed for a small STHE with five different cases for the ratio of the leakage cross-sectional area to the baffle cross-sectional area, ranging from 0 to 40%, in order to determine the optimum leakage flow corresponding to the maximum outlet temperature. Using fixed tube wall and inlet temperatures for the shell side of the STHE, the flow and temperature fields were calculated by increasing the Reynolds number from 4952 to 14858. The present results showed that the outlet temperature, pressure drop, and heat transfer coefficient were strongly affected by the leakage flow, as well as the Reynolds number. In contrast with a previous researcher's finding that the leakage flow led to simultaneous decreases in the pressure drop and heat transfer rate, the present study found that the pertinent leakage flow provided momentum in the recirculation zone near the baffle plate and thus led to the maximum outlet temperature, a small pressure drop, and the highest heat transfer rate. The optimum leakage flow was shown in the case with a ratio of 20% among the five different cases.

Analysis of Heat Transfer Performance of a Gas Cooler of CO2 Heat Pump for Water Heating (온수제조용 CO2 히트펌프의 가스쿨러 열전달 성능 해석)

  • Kwon, Jeong-Tae;Lee, Chang-Kyung;Baek, Dong-Seok;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5317-5322
    • /
    • 2013
  • This study presents a prediction method for heat transfer performance of a gas cooler of $CO_2$ heat pump using ${\epsilon}$-NTU method, and compared the results with the experimental data from the open literature. The heat transfer rate, refrigerant side outlet temperature and water side outlet temperature were calculated by using EES(Engineering Equation Solver)program in multi-tube-in-tube type $CO_2$ heat pump gas cooler. Analysis was performed in two methods : The first method performed without dividing into the test section by applying an analysis of the mean properties(mean analysis). The second method, tube length divided into 50 sections, was applied to the local properties(local analysis). From the present study, a good agreement at the local analysis was obtained between the analytical and experimental results by 0.3~1.1%, 1.31~1.88% and 3.12~5.18% for heat transfer rate, water and refrigerant side outlet temperatures, respectively.

Numerical Study of Aerodynamics of Turbine Rotor with Leading Edge Modification Near Hub (허브 측 선단 수정에 따른 터빈 로터의 공력 특성에 대한 수치적 연구)

  • Kim, Dae Hyun;Lee, Won Suk;Chung, Jin Taek
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1007-1013
    • /
    • 2013
  • This study aims to analyze the aerodynamics when the geometry of the turbine rotor is modified. The turbine used in this study is a small engine used in the APU of a helicopter. It is difficult to improve the performance of small engines owing to the structural weakness of the blade tip. Therefore, the improvement of the hub geometry is investigated in many ways. The working fluid of a turbine is a high-temperature and high-pressure gas. The heat transfer rate of the turbine surface should be considered to avoid the destruction of blade owing to the heat load. The SST turbulence model gives an excellent prediction of the aerodynamic behavior and heat transfer characteristics when the numerical simulations are compared with the experimental results. In conclusion, the aerodynamic efficiency is improved when a bulbous design is applied to the leading edge near the hub. The endwall loss is reduced by 15%.