• Title/Summary/Keyword: 열저항-열용량법

검색결과 3건 처리시간 0.015초

열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석 (Analysis of energy consumption of office building by thermal resistance-capacitance method)

  • 이창선;최영돈
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

복사열전달을 고려한 고층아파트 연속난방 열공급제어 시뮬레이션 (Simulation of Heat Supply Control of Continuous Heating System of Multistoried Apartment in Consideration of Radiation Heat Transfer)

  • 최영돈;홍진관;윤종호;이남호
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.78-92
    • /
    • 1994
  • Thermal performance of pipe network of continuous heating system controlled by thermostat and flow control valve was simulated in consideration of radiation heat transfer and solved by linear analysis method. Thermal performance of real apartment building with radiant floor heating system was simulated by equivalence heat resistance-capacity method. This method enables to simulate the unsteady variation of temperature or each element of building. Heat transfer characteristics of each element were also investigated.

  • PDF

건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구 (An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.203-211
    • /
    • 2021
  • 최근 건축물의 에너지 사용 저감을 위한 단열 설계기준은 강화되고 있다. 단열공사는 건축물의 단위면적당 1차 에너지 소요량 저감을 위한 가장 효율적인 방법임에도 불구하고, 건축 시공 및 준공검사 과정에서 단열성능에 대한 평가(검사) 기준이 없는 실정이다. 본 연구는 열관류율 측정장비(TESTO 435)를 활용하여 공동주택의 외벽 열관류율을 간편하게 실험 할 수 있는 방법과 분석기법에 대한 기준을 구축하여 객관적인 데이터를 제공하는 데 목적이 있다. 실험 대상 외벽의 단위면적당 비열(열용량)이 20 kJ(m2·K)를 초과하여 ISO 9869-1에 적합한 종료 시점의 데이터를 평균법으로 분석했다. 3일 연속 열관류율 측정값은 설계값 대비 +5% 이내로 허용오차 범위 내로 수렴했고, 일자별 열관류율의 표준편차는 1-Day > 3-Day > 2-Day 순으로 작아졌고, 시간대별 열관류율 표준편차는 00:00~24:00 > 19:00~07:00 > 00:00~07:00 순으로 줄어 들었다. 특히, 측정일자별로 00:00~07:00 시간대의 열관류율 값은 설계값 대비 -3%~+2% 편차로 거의 일치하였다.