• Title/Summary/Keyword: 열저항식

Search Result 107, Processing Time 0.029 seconds

Preliminary Analysis of the CANDU Moderator Thermal-Hydraulics using the CUPID Code (2상 유동 해석코드 CUPID를 이용한 CANDU 원자로 감속재 열수력 예비해석)

  • Park, Sang Gi;Lee, Jae Ryong;Yoon, Han Young;Kim, Hyoung Tae;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.419-426
    • /
    • 2012
  • A transient, three-dimensional, two-phase flow analysis code, CUPID, has been developed in KAERI. In this work, we performed a preliminary analysis using the CUPID code to investigate the thermal-hydraulic behavior of the moderator in the Calandria vessel of a CANDU reactor. At first, we validated the CUPID code using the three experiments that were performed at Stern Laboratories Inc. To avoid the complexity to generate computational mesh around the Calandria tube bundles, a porous media approach was applied for the region. The pressure drop in the porous media zone was modeled by an empirical correlation. The results of the calculations showed that the CUPID code can predict the mixed flow pattern of forced and natural convection inside the Calandria vessel very well. Thereafter, the analysis was extended to a two-phase flow condition. Also, the local maximum temperature in the Calandria vessel was plotted as a function of the injection flow rate, which may be utilized to predict the local subcooling margin.

KSTAR 토카막 플라즈마 가열을 위한 중성 입자빔 입사장치용 이온원 개발 현황

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol;O, Byeong-Hun;Jang, Dae-Sik;Jin, Jeong-Tae;Song, U-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.559-559
    • /
    • 2013
  • KSTAR (Korea Superconducting Tokamak Advanced Research) 장치는 차세대 에너지원 중의 하나인 핵융합로를 위한 과학기술 기반을 마련하기 위해 개발된 중형급 토카막 실험장치로서 토카막 운전 영역의 확장과 안정성 확보, 정상상태 운전 도달을 위한 방법 연구, 최적화된 플라즈마 상태와 연속 운전 실현 등을 주요 목표로 하고 있다. 이를 위해 핵융합 반응에 의한 점화조건과 가까운 상태로 플라즈마를 가열해주어야 하며, 토카막 장치의 저항가열 이외에도 외부에서 추가 가열이 반드시 필요하다. 중성 입자빔 입사 장치는 현재 토카막에서 사용되고 있는 가열장치 중 가장 신뢰성있는 추가 가열 장치라 할 수 있으며 한국 원자력연구원에서는 1997년부터 KSTAR 토카막 실험 장치에 사용될 중성 입자빔 입사 장치를 개발해왔었다. 중성빔 입사 장치는 크게 이온원, 진공함, 열량계, 진공 펌프, 중성화 장치, 이온덤프와 전자석으로 이루어져 있으며, 이중 이온원은 중성빔의 성능을 좌우하는 핵심적인 장치라 할 수 있다. 최근 한국원자력연구원에서는 2 MW 중성 입자빔 입사장치용 이온원 개발을 완료하여 KSTAR 토카막 장치에 설치하였으며, 2013년 현재 KSTAR에는 총 두 개의 이온원이 장착되어 최대 약 3 MW 이상의 중수소 중성 입자빔을 입사하여 KSTAR 토카막 실험의 H-mode 달성과 운전 시나리오 연구에 많은 기여를 하고 있다. 한국원자력연구원에서 최초로 개발된 이온원은 미국 TFTR 장치에서 사용되었던 US LPIS (Long Pulse Ion Source)를 기본으로 하여 국내 개발을 수행하였다. 이 온원은 크게 플라즈마를 발생시키는 플라즈마 발생부와 발생된 이온을 인출 및 가속시키는 가속부로 구성되는데, 개발과정에서 가장 먼저 KSTAR의 장주기 운전에 적합하도록 플라즈마 방전부와 가속부의 냉각회로를 요구되는 열부하에 맞게 설계 수정하였다. 그 후 플라즈마 방전부는 방전 시간과 안정성, 플라즈마 밀도의 균일도, 정격 운전, 방전 효율 등을 고려하여 수정 보완하며 개발을 진행하여왔다. 가속부의 경우 국내 제작기술의 한계를 극복하기 위해 빔 인출그리드를 TFTR의 US LPIS 모델의 슬릿형 그리드 타입에서 원형 인출구 타입으로 변경하였으며, 이후 가속 전극의 고전압 내전력 문제, 빔 인출 전류와 전력, 인출 빔의 광학적 질(quality), 빔 인출 시간 동안의 안정성 등을 위해 그리드의 크기와 간격, 모양 등을 변경하여 개발을 수 행하여 왔다. 이 논문은 한국원자력연구원에서 개발이 진행되어 왔던 이온원들을 시간적으로 되짚어 보면서 현재까지의 성과와 문제점, 그리고 앞으로의 개발 방향에 대해 논의하고자 한다.

  • PDF

Cure Behaviors and Fracture Toughness of PEl/Difunctional Epoxy Blends (PEI/DGEBA 블랜드계의 열적특성 및 파괴인성)

  • Park, Soo-Jin;Jin, Sung-Yeol;Kaang, Shinyoung
    • Journal of Adhesion and Interface
    • /
    • v.4 no.3
    • /
    • pp.33-40
    • /
    • 2003
  • In this work, diglycidyl ether of bisphenol A (DGEBA)/polyetherimide (PEI) blends were cured using 4,4-diaminodiphenyl methane (DDM). And the effects of addition of different PEI contents to neat DGEBA were investigated in the thermal properties and fracture toughness of the blends. The contents of contents of containing PEI were varied in 0, 2.5, 5, 7.5, and 10 phr. The cure activation energies ($E_a$) of the cured specimens were determined by Kissinger equation and the mechanical interfacial properties of the specimens were performed by critical stress intensity factor ($K_{IC}$). Also their surfaces were examined by using a scanning electron microscope (SEM) and the surface energetics of blends was determined by contact angles. As a result, $E_a$ and $K_{IC}$ showed maximum values in the 7.5 phr PEI. This result was interpreted in the increment of the network structure of DGEBA/PEI blends. Also, the surface energetics of the DGEBA/PEI blends showed a similar behavior with the results of $K_{IC}$. This was probably due to the improving of specific or polor component of the surface free energy of DGEBA/PEI blends, resulting in increasing the hydrogen bonding of the hydroxyl and imide groups of the blends.

  • PDF

Studies on Thermophilic Flat-sour Bacteria in Soymilk: Isolation, Indentification and Determination of Heat Resistance (두유내의 고온성 Flat-sour 변질균의 분리.동정 및 열저항성에 관한 연구)

  • Chung, Je-Bong;Lee, Kyun-Hee;Sohn, Heon-Soo;Kim, Suk-Min
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.218-224
    • /
    • 1988
  • For the optimization of thermal processing conditions in soymilk process, 4 strains of thermoresistant flat-sour bacteria were isolated from soymilk. The isolates were aerobic spore-forming rods, and grew at $-65^{\circ}C$. Based on the morphological and physiological properties, all of the isolated strains were identified as Bacillus stearothermophilus. The heat resistance of spores of 3 isolates and Bacillus stearothermophillus ATCC 12980 as a reference was determined in soymilk(pH 7.0) and pH 7.0 buffer solution. For each of the spores studied, linear regression equations with standard error were presented for the thermal destruction at 110, 115, 121, and $125^{\circ}C$. It was not obvious that the components of soy milk increased the heat resistance of spores. Between the strains studied, variability was noted in the D values at the different temperature, and no one strain was consistently the most heat resistant at all the given temperatures. The average D value for the 4 strains was 77.27, 20.20, 2.76 and 1.39 min at 110, 115, 121 and $125^{\circ}C$, respectively, and the average z value was $8.36^{\circ}C$.

  • PDF

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

Comparison of the Effects of Cyclodextrin-Naringin Inclusion Complex with Naringin on Lipid Metabolism in Mice Fed a High-Fat Diet (고지방식이를 섭취한 마우스에서 나린진과 나린진-사이클로텍스트린 포접화합물의 지질대사에 대한 영향 비교)

  • Jeon, Seon-Min;Choi, Myung-Sook
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.20 no.1
    • /
    • pp.20-29
    • /
    • 2010
  • Naringin has antioxidant and antihyperlipidemic properties, however, phenolic compounds including naringin are unstable in the presence of light, heat and oxygen. Beta-cyclodextrin ($\beta$-CD) is a cyclic heptamer composed of seven glucose units that enhances the stability and solubility of molecules through the formation of inclusion complexes. This study was conducted out to compare the effects of CD-naringin (CD-N) inclusion complexes with naringin on lipid metabolism in high fat-fed animals. Male C57BL/6 mice were fed either CD-N (0.048%, w/w) or naringin (N, 0.02%, w/w) in a 20% high-fat (HFC, 15% lard, 5% corn oil, w/w) diet for 10 weeks. Orlistat (Xenical, 0.01%, w/w) was used as a positive control (PC). There were no differences in body weight, food intake, liver and heart weights, plasma triglyceride(TG), leptin, adiponectin, resistin, IL-$1{\beta}$ and IL-6 concentrations, and hepatic $\beta$-oxidation, carnitine palmitoyl transferase(CPT), glucose-6-phosphate dehydrogenase (G6PD) and malic enzyme activities between the HFC and CD-N groups or between the HFC and N groups. However, both CD-naringin and naringin supplementation les to a significant reduction in the epididymal and perirenal white adipose tissue weights, plasma free fatty acid, insulin and blood glucose concentrations, hepatic cholesterol and TG contents and hepatic fatty acid synthase (FAS), phosphatidate phosphohydrolase (PAP) and HMG-CoA reductase activities compared to the HFC group. The plasma HDL-cholesterol concentration was significantly higher in CD-N and N groups than in HF and PC groups. These results indicate that both CD-naringin and naringin supplementation effectively improved plasma and hepatic lipid metabolism without differences between CD-N and naringin groups.

Silicon Supply through Subirrigation System Alleviates High Temperature Stress in Poinsettia by Enhancing Photosynthetic Rate (저면공급한 규소에 의한 포인세티아의 광합성 능력 향상과 고온 스트레스 경감)

  • Son, Moon Sook;Park, Yoo Gyeong;Sivanesan, Iyyakkannu;Ko, Chung Ho;Jeong, Byoung Ryong
    • Horticultural Science & Technology
    • /
    • v.33 no.6
    • /
    • pp.860-868
    • /
    • 2015
  • The effect of Si supplied during plant cultivation on tolerance to high temperature stress in Euphorbia pulcherrima Willd. 'Ichiban' was investigated. Rooted cuttings were transplanted into 10-cm pots and a complete nutrient solution, containing 0 or $50mg{\cdot}L^{-1}$ Si as either $K_2SiO_3$, $Na_2SiO_3$, or $CaSiO_3$, was supplied through subirrigation or weekly foliar applications. After two months of cultivation, plants were placed in an environment-controlled chamber and subjected to $35{\pm}1^{\circ}C$ (high temperature) conditions for 18 days. Enhanced specific activities of enzymatic antioxidants (APX) and suppressed specific activities of non-enzymatic antioxidants (ELP) were observed in the high temperature-stressed plants with Si application. The Fv/Fm (maximum quantum yield of photosystem II), photosynthetic rate, and Si contents in the shoot increased in the treatments of $K_2SiO_3$ and $Na_2SiO_3$ supplied through subirrigation. The Si-treated plants had more tolerance of high temperature stress than the control plants. Of the Si sources and application methods tested, $K_2SiO_3$ and $Na_2SiO_3$ supplied through subirrigation were found to be the most effective in enhancing tolerance to high temperature stress.

Analysis of Shear Flow Dispersion Using Sequential Mixing Model (순차혼합모형에 의한 전단류 분산 해석)

  • Seo, Il-Won;Son, Eun-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.991-995
    • /
    • 2005
  • 본 연구에서는 1차원 이송-분산 과정을 연구하고 전단류 흐름 및 분산거동에 있어 Taylor 이론의 핵심이라 할 수 있는 '종방향 이송과 횡방향 확산의 균형'을 기본 개념으로 하여, 이송과 확산을 분리하여 이 두 과정이 순차적으로 발생한다는 가정에 의거한 순차혼합모형을 제시하였다. 본 모형에서는 가상의 하천을 여러 개의 행과 종방향 거리를 길이가 일정한 구획으로 나누어 연속적인 분산과정을 이산적인 형태로 나타낼 수 있게 하고, 횡방향 유속분포에 따라 각 행에 각기 다른 유속을 할당한다. 오염물질은 하폭방향 선오염원으로 원점에 순간주입되며, 주어진 혼합시간 $t_m$ 동안 각 행의 오염물질들이 각자에 할당된 유속을 따라 진행하고 진행이 끝난 후 횡방향 확산이 순간적으로 이루어진다. 횡방향 확산은 횡방향으로 완전하게 일어남을 가정하여, 횡방향 확산이 끝나면 각 열에서의 농도 평균값이 할당된다. 이러한 혼합시간 $t_m$ 동안의 순차적인 이송-확산 과정이 반복되면서 오염물질의 분산이 일어나며, 농도 분포 그래프를 그릴 수 있게 된다. 순차혼합모형을 가상의 직선하천에 적용하여 종분산계수를 유도하였는데, 본 연구에서 유도된 종분산계순식은 Fischer.가 제안한 식과 유사한 형태로 나타남을 알 수 있었다. 본 모형에서 계산된 농도분포 곡선을 해석해와 비교한 결과,두 곡선이 적절히 일치함을 확인할 수 있었으며 해석해와의 비교를 통해 종분산계수 K가 혼합시간 $t_m$과 선형관계임을 확인할 수 있었다. 수심대하폭비에 따라 각기 다른 유속분포에 적용하여 종분산계수 K가 유속편차강도의 제곱에 비례관계에 있음이 밝힐 수 있었다. 수압은 $4.69kg/cm^2$으로 나타났다. 밸브 개폐도가 $100\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$

  • PDF

Energy efficiency improvements in part load for a marine auxiliary diesel engine (선박발전기용 디젤엔진의 부분부하에서 에너지 효율 개선에 관한연구)

  • Jung, Kyun-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.877-882
    • /
    • 2014
  • The reduction of CO2 emission has been discussed in the Marine Environment Protection committee in the International Maritime Organization as the biggest causes of GHG for the purpose of indexing CO2 amounts released into the atmosphere from ships. Accordingly, various methods including the change in the hull design to improve energy efficiency, the coating development to reduce friction resistances, the additives development for improving thermal efficiency in an engine, the low-speed operation to reduce fuel consumptions, and etc. have been applied. The main engine of a ship is an electronic engine for improving the efficiency of the whole load area. However, marine generator engines still use mechanical drive engines in intake, exhaust, and fuel injection valve drive cams. In addition, most of marine generator engines in ships apply a part-load operation of less then 80% due to an overload protection system. Therefore, marine auxiliary diesel engine set at 100% load is necessary to readjust in order to efficient operation because of part-load operation. The objective of this study is to report the results of the part-load fuel consumption improvement by injection timing readjust to identifying the operational characteristics of a marine generator engine currently operated in a ship.

An Experimental Study on the Effect of Combined X-ray and Microwave Hyperthermia on the Rectum and Urinary Bladder of Rats (흰쥐의 직장과 방광에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구)

  • Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.115-128
    • /
    • 1986
  • Hyperthermia can enhance the radiation effect as a synergistic reaction in combined X-ray irradiation and hyperthermia; hyperthermia sensitize radioresistant S-phase cells and inhibit cellular recovery from sublethal damage. We fabricated 100 watts, 2450 MHz microwave applicator for hyperthermia and planned the method and condition of heating and measured the temperature by using Agar phantom as a preliminary test. For biological examination, 102 rats were divided into 4 groups as hyperthermia, X-ray irradiation (6Gy-15Gy), combined X-ray and hyperthermia, and normal control groups. Microscopic examination of the rectum and bladder was done and the results were as followings: 1. The microwave generator with 100 watts, 2450MHz magnetron could be heating up to $40^{\circ}{\sim}50^{\circ}C$ for one hour in living tissue. 2. The thermal distribution in tissue equivalent phantom with microwave can be maintained at $40^{\circ}{\sim}44^{\circ}C$ in area of 3cm in depth and 2-10cm in diameter. 3. In Hyperthermia alone group, there was submucosal edema of the rectum but no histologic change in the urinary bladder was seen. 4. The minimal necrosis of the mucosa was appeared in the rectum and bladder after 15 days of 6 Gy and 8 Gy irradiation respectively. The minimal necrosis of the muscle layer of rectum and bladder was appeared after 15 days of 8Gy and 60days of 10Gy irradiation respectively. 5. In combined group of radiation and hyperthermia, thermal enhancement ratio (calculated at necrosis of mucosa and muscle layer) of rectum and bladder was 1.0, and it suggest that there is no change of tolerance dose of normal rectum and bladder.

  • PDF