• 제목/요약/키워드: 열유동해석

검색결과 273건 처리시간 0.027초

Ti 와이어 피딩에 따른 페라이트계 스테인레스강 제강시 열유동 해석 (Heat Flow Analysis of Ferritic Stainless Steel Melt during Ti wire feeding)

  • 김민기;황동찬;최재주;신상윤;예병준;김지훈;김원배
    • 한국주조공학회지
    • /
    • 제29권6호
    • /
    • pp.277-283
    • /
    • 2009
  • Recently an increase in production cost of 300 series stainless steel with a sudden increase in nickel cost has caused a decrease in demand for 300 series stainless steel so that 400 series stainless steel has begun to make a mark. Although 400 series stainless steel has good properties, it has a problem of lack of corrosion resistance. There is Ti in 400 series stainless steel alloys to solve the problem above and it has lower density than the others. For that reason, wire feeding process has been applied for adding Ti alloy in 400 series stainless steel. This paper presents consideration of variation on the depth of wire dissolution by conditions of wire feeding which are wire injection speed, the temperature of molten steel, wire diameter and bubble generation rate. The computer program for solution of conducting wire feeding has been developed in Flow3D.

순산소 전로의 증기드럼 내의 3차원 열 유동 해석모델 개발 (Development of Three-dimensional Thermo-fluid Numerical Model for Steam Drum of a Basic Oxygen Furnace)

  • 정수진;문성준;장원준;고순탁;곽호택
    • Korean Chemical Engineering Research
    • /
    • 제54권4호
    • /
    • pp.479-486
    • /
    • 2016
  • 순산소 전로 후드의 일산화탄소와 열회수를 위해서는 고효율의 증기를 발생시키는 증기드럼의 장착이 필요하다. 그러나 제선 제강공정에서 증기발생은 간헐적이거나 주기적인 산소 취입공정기간에 제한적이다. 따라서, 증기드럼은 전로의 주기에 따른 산소의 취련기간 동안 효율적으로 증기를 발생시키도록 최적 설계되어야 한다. 따라서 본 연구에서는 다양한 운전조건 및 기하학적 형상변화가 증기드럼 내의 열유동 특성과 성능에 미치는 효과를 예측할 수 있는 3차원 전산유체역학 모델을 제안하였다. 본 모델은 유체유동 및 열전달 뿐만 아니라 계면유동에서의 증발 및 응축을 유한체적법을 사용하여 고려하였다. 본 모델의 예측성능을 검증하기 위하여 실험에서 구한 증기발생량과 비교하였으며 3.2%의 상대오차를 보였다.

미세물분무 작동에 대한 FDS 예측 성능 평가 (Estimation of FDS Prediction Performance on the Operation of Water-Mist)

  • 고권현
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.4809-4814
    • /
    • 2014
  • 본 논문은 미세물분무 작동에 따른 화재 거동 및 제압 특성을 예측하는 데 있어서 FDS(Fire Dynamic Simulator)의 예측 성능을 평가하는 것을 목적으로 한다. 미세물분무의 초기액적분포 입력을 위해 Rosin-Rammler /log-normal 분포를 사용하였으며 모델 상수의 영향을 살펴보았다. 또한 미세물분무의 분사압력에 따른 화재 제압특성을 이전의 실험 결과와 비교함으로써 해석 모델을 검증하고 열유동 특성 및 가스 농도 변화를 분석하였다. 결과로부터 동일한 평균입경을 갖는 미세물분무도 액적분포의 특성에 따라 하부 위치에서의 액적 크기 및 속도에 큰 영향을 받고 있음을 확인할 수 있었다. 분무특성에 대한 실험결과와의 비교를 통해 적절한 초기입경분포를 결정하였으며 이를 이용하여 화재 시뮬레이션을 진행하였다. FDS 화재 시뮬레이션 결과는 온도의 변화 및 화재 제압 특성에 대하여 실험 결과와 좋은 일치를 보여주었다. 또한 미세물분무의 작동압력에 따른 열유동장 변화, 가스상 농도 변화의 예측에 있어 유용한 데이터를 제공할 수 있음을 확인하였다.

IGCC 합성가스 급속 냉각시스템의 운전 압력에 따른 열유동 및 입자 거동 특성 연구 (Effect of Operating Pressure on the Heat Transfer and Particle Flow Characteristics in the Syngas Quench System of an IGCC Process)

  • 박상빈;양주향;오준호;예인수;류창국;박성구
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.97-104
    • /
    • 2014
  • In a coal gasifier for IGCC, hot syngas leaving the gasifier at about 1550oC is rapidly quenched by cold syngas recycled from the gas cleaning process. This study investigated the flow and heat transfer characteristics in the gas quench system of a commercial IGCC process plant under different operating pressures. As the operating pressure increased from 30 bar to 50 bar, the reduced gas velocity shortened the hot syngas core. The hot fly slag particles were retained within the core more effectively, and the heat transfer became more intensive around the hot gas core under higher pressures. Despite the high particle concentrations, the wall erosion by particle impaction was estimated not significant. However, large particles became more stagnant in the transfer duct due to the reduced gas velocity and drag force under higher pressures.

디젤 차량의 보조 난방을 위한 PTC 히터 개발 (Development of a PTC Heater for Supplementary Heating in a Diesel Vehicle)

  • 신윤혁;김성철
    • 한국산학기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.666-671
    • /
    • 2014
  • 최근 디젤 차량과 같은 내연기관의 고효율화에 따라, 보조난방 열원으로서 PTC 히터의 사용이 증가하는 추세이다. 디젤 차량의 시동 초기에는 냉각수의 온도가 난방으로 직접 사용하기에 충분히 높지 않으므로, 동절기 난방을 위해 보조난방 열원은 필수적이다. 본 연구에서는 스크린 인쇄 전극공정을 바탕으로 한 PTC 소자를 제작하였고, 이를 활용한 PTC 소자 모듈 및 히터를 설계 및 제작하였다. PTC 소자 모듈의 방열핀 접촉형상 및 전열소자의 크기 변경에 따른 난방성능 변화를 열유동 해석을 통해 분석하였고, 난방성능 실험을 수행하여 PTC 히터의 난방성능 및 효율 특성을 살펴보았다. PTC 히터 시작품의 경우, 기존 PTC 히터와 동등한 수준 이상의 난방성능 및 효율을 나타내었으며, 향후 이를 바탕으로 PTC 소자와 히터에 대한 공정개선 및 성능증대 연구를 수행할 계획이다.

X-ray tube 내 열유동 해석에 관한 연구 (A study on the analysis of heat flow in X-ray tube)

  • 윤동민;서병석;전용한
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.26-31
    • /
    • 2021
  • As the aging ages, the disease also increases, and the development of AI technology and X-ray equipment used to treat patients' diseases is also progressing a lot. X-ray tube converts only 1% of electron energy into X-ray and 99% into thermal energy. Therefore, when the cooling time of the anode and the X-ray tube are frequently used in large hospitals, the amount of X-ray emission increases due to temperature rise, the image quality deteriorates due to the difference in X-ray dose, and the lifespan of the overheated X-ray tube may be shortened. Therefore, in this study, temperature rise and cooling time of 60kW, 75kW, and 90kW of X-ray tube anode input power were studied. In the X-ray Tube One shot 0.1s, the section where the temperature rises fastest is 0.03s from 0s, and it is judged that the temperature has risen by more than 50%. The section in which the temperature drop changes most rapidly at 20 seconds of cooling time for the X-ray tube is 0.1 seconds to 0.2 seconds, and it is judged that a high temperature drop of about 65% or more has occurred. After 20 seconds of cooling time from 0 seconds to 0.1 seconds of the X-ray tube, the temperature is expected to rise by more than 3.7% from the beginning. In particular, since 90kW can be damaged by thermal shock at high temperatures, it is necessary to increase the surface area of the anode or to require an efficient cooling system.

이론적 열유동 및 랜덤 진동 해석을 적용한 EPS 보냉용기의 포장설계 (Packaging Design of EPS Cooling Box by Theoretical Heat Flow and Random Vibration Analysis)

  • 김수현;박상훈;이민아;정현모
    • 한국포장학회지
    • /
    • 제27권3호
    • /
    • pp.175-180
    • /
    • 2021
  • Although it has recently been regulated for use as an eco-friendly policy in Korea, the use of EPS (Expanded Polystyrene) cooling boxes, which are used as cold chain delivery insulation boxes for fresh agricultural and livestock products, is also increasing rapidly as e-commerce logistics such as delivery have increased rapidly due to COVID-19. Studies were conducted to optimize the EPS cooling container through internal air heat flow of CFD (Computational Fluid Dynamics) analysis and FEM (Finite Element Method) random vibration analysis using domestic PSD (Power Spectral Density) profile of the EPS cooling box to which the refrigerant is applied in this study. In the analysis of the internal air heat flow by the refrigerant in the EPS cooling box, the application of vertical protrusions inside was excellent in volume heat flow and internal air temperature distribution. In addition, as a result of random vibration analysis, the internal vertical protrusion gives the rigid effect of the cooling box, so that displacement and stress generation due to vibration during transport are smaller than that of a general cooling container without protrusion. By utilizing the resonance point (frequency) of the EPS cooling box derived by the Model analysis of ANSYS Software, it can be applied to the insulation and cushion packaging design of the EPS product line, which is widely used as insulation and cushion materials.

이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계 (Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis)

  • 최동수;김용훈;김진세;박천완;정현모;김기석;박종민
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

램제트 엔진에서의 화염 전파와 비정상 연소 현상에 관한 수치해석

  • 성홍계
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2000년도 제14회 학술강연논문집
    • /
    • pp.10-10
    • /
    • 2000
  • 램제트 엔진은 비추력이 높고 추력 레벨은 낮으므로, 2단 추진기관에 적합한 추진 시스템이다. 1단-추진기관의 작동이 끝나고, 2단 램제트 엔진이 점화 후 안정된 연소에 도달되기까지 비행체의 속도는 항력에 의하여, 초당 약 마하수 0.1 정도씩 감소된다. 1단 연소 후 2단 램제트로 전환되는 지연시간이 길수록 1단에서 요구되는 종말 가속도는 증가되므로, 1단이 차지하게되는 부피는 증가되고 비행체의 크기 또한 늘어나게 된다. 따라서 1단에서 2단 램제트로 천이되는데 소요되는 시간을 가능한 짧게 하는 것이 효과적이다. 그러나 램제트 엔진의 특성상 선결되어야할 다음과 같은 여러 문제들이 있다. 첫째, 1단 작동 시 공기 흡입구와 연소실은 차단벽으로 분리되어 있다가, 1단 연소후 차단막이 제거되어 외부공기가 램제트 연소실로 흡입된다. 흡입되는 공기는 흡입구의 형상에 의하여 램 압축되지만 초음속으로 연소실을 통과하게된다. 연료 주입 구에서 공급되는 연료는 연소실에서 유동의 흐름방향(streamline)에 따라서 연소실로 확산되는데, 연소되기 전에는 유속이 빠르게 노즐로 빠져 나가므로 램제트 연료가 재순환 구역(recirculation zone)으로 침투하는데 쉽지가 않다. 둘째, 연소실 입구에서 발생되는 와류 (ring vortex)는 1단 연료의 고온 연소 가스를 연소실로 확산시키는데, 비 균일한 온도 분포를 유발하여 램제트 연료의 점화에너지가 공급되는 시간이 적당하지 않을 경우 균일한 화염 전파에 악영향을 준다. 셋째, 연소실에서의 빠른 유동 조건은 연료가 연소실에 머무를 수 있는 시간을 감소시키며, 연소실 입구에서 강한 전단 응력이 발생되어 화염이 안정화되는데 악 영향을 미치게된다. 본 논문은 공기 흡입구, 연소실 및 노즐을 통합하여 수치해석을 하였으며 열유동/점화/연소등의 미케니즘을 이해하고, 주요 인자들 중 와류의 영향에 초점을 맞추었다.다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14) 식도경 시행회수는 1회가 17례(54.8%), 2회가 9례(29.0%), 3회 이상이 5례(16.1%)였다.EX>$IC_{50}$/ 값이 210 $\mu\textrm{g}$/$m\ell$로서 효과적

  • PDF

발전소 터빈건물의 창문 위치에 따른 온도저감 (Temperature Reduction with the Location of Window in a Turbine Building of Power Plant)

  • 하지수;김태권;정경호
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.207-213
    • /
    • 2016
  • 본 연구에서는 화력발전소 터빈 건물의 온도저감 방안을 도출하기 위해 전산유체역학 상용코드인 ANSYS-FLUENT를 이용하여 열유동 해석을 수행하였다. 터빈 건물의 운전층(operating floor)과 탈기기층(deaerator floor)을 검사체적으로 선정하여 모델링을 하였으며 탈기기층에 설치된 기존의 채광창을 활용하여 환기창으로 대체하는 경우에 대해 해석을 수행하였다. 본 연구를 통하여 첫째, 운전층의 온도를 저감하기 위한 방안은 탈기기층의 모든 창문을 열지 않아야 됨을 알았다. 둘째, 탈기기층의 온도를 저감하기 위한 방안으로 탈기기층의 전면부의 창문을 개방하면 탈기기 영역과 크레인 영역은 각각 $1.5^{\circ}C$$1.6^{\circ}C$를 저감할 수 있었고, 탈기기 후면부의 창문을 개방하면 탈기기 영역은 $1.4^{\circ}C$, 크레인 영역은 $0.5^{\circ}C$의 온도를 저감할 수 있었다. 따라서 고온의 탈기기층 전체 영역의 온도를 저감하기 위해서는 탈기기층 전면부의 창문을 개방하는 것이 유리할 것으로 판단된다.