• Title/Summary/Keyword: 열부하 분포

Search Result 47, Processing Time 0.025 seconds

A Survey on the Co-Generation Load for Large Commercial Buildings (대형상업건물의 열병합발전 부하조사)

  • 한승호;권순우;정상원;정재혁
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 1998
  • Energy consumption statistics have been surveyed for 50 large commercial buildings with high energy consumption records in Seoul City. The buildings were classified into three different groups for data analysis: hospitals, hotels, and department stores/office buildings. The analysis was focused on identifying installed boiler and refrigerator data, energy consumption rates, and energy load distribution throughout the year. Refrigerating electricity was confirmed again to affect most on the formation of the summer electricity load peak as expected. Replacing the refrigerator electricity peak in the summer with co-generation in large commercial buildings. However, overall heat load distribution in a single building is still considered not large enough for economically feasible co-generation and thus joint co-generation for multiple neighboring buildings are preferred and the Electric Power Law and LNG pricing policy should be revised favorably for co-generation in advance.

  • PDF

Analysis of the electromagnetic fields in microwave cavities and the temperature fields in loads using Finite-Difference Time Domain method (FDTD방법을 이용한 마이크로웨이브오븐의 전자파 해석 및 부하의 열해석)

  • Cho, S.H.;Lee, Y.M.;Kim, H.J.;Kang, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2459-2461
    • /
    • 1999
  • FDTD(Finite-Difference Time-Domain) 방법을 이용하여 마이크로웨이브 오븐 내부 전자파를 해석하였고, 열전달방정식을 이용하여 부하의 열 분포를 해석하였다. 다양한 형태의 오프닝구조를 갖는 캐비티에 관하여 수치계산을 수행하였고, 서로 다른 종류의 부하가 존재할 때 부하의 온도 분포가 어떻게 변화하는지 알아보았다. 또한 마그네트론의 안테나와 캡이 존재하는 실제 웨이브가이드를 모델링하여 수치 계산한 후, 적외선사진에 의한 부하의 온도분포와 비교하였다.

  • PDF

Analysis of Condenser Thermal Distribution by the Variance of Voltage & Frequency (전압 및 주파수 변동에 따른 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.33-36
    • /
    • 2009
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 콘덴서는 전압이 증가할 경우 전류도 함께 증가하고, 주파수가 증가할 경우 콘덴서에 흐르는 전류가 증가하기 때문에 전류의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 콘덴서에 인가되는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열을 열화상 카메라로 측정하여 외부 및 내부에서의 온도분포를 분석하였다. 측정결과 전압과 주파수가 증가할 경우 콘덴서에서 열이 매우 높게 분포함을 확인할 수 있었다.

  • PDF

A Study on Boundary Conditions of Piston Thermal Loading Analysis in Internal Combustion Engines (내연기관 피스톤의 열부하 해석을 위한 경제조건 설정에 관한 연구)

  • 정동수;조용석;최헌오;이진형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.528-533
    • /
    • 1988
  • The assignment of boundary conditions for the piston thermal loading analysis in internal combustion engine has been tested using the thermal circuit method with an engine simulation program. In an attempt to examine the accuracy of the employed boundary condition, another thermal boundary condition has been sought for through the electrolytic tank analogue method. Comparison of calculated temperature distributions obtained from these two boundary conditions with measured temperature values reveals that the electrolytic tank analogue method gives excellent agreement. However, the thermal circuit method has been found to be reasonable for practical applications, if modified partially.

Analysis for Thermal Distribution of Low-voltage Condenser by the Variance of Voltage & Frequency (전압 및 주파수 변화에 따른 저압 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.43-49
    • /
    • 2010
  • Power capacitor has been used to compensate for the low power factor of inductive load and to reduce harmonics generated by the power conversion device with reactor. The increase of voltage and current and thermal generation are extremely hard on the life of condenser. Current will be increased, provided that voltage and frequency of condenser increase also. The increase of voltage and frequency justly extends thermal generation. Both act on insulation stress and can afford to premature fault In this paper, we measured thermal distribution of condenser with infrared rays camera in case of variance of voltage and frequency. We were assured that the increase of voltage and frequency produces high heat and exceedingly shortens the life of condenser.

An Analysis on the 500m - Mesh Classification based on the Heat Consumption Density in Busan (부산시 500m 메시 레벨에서의 에너지소비량 분포 분석)

  • Hwang, Kwang-Il;Choi, Duk-In;Kim, Da-Hye;Yang, Ing-Chan;Yoon, So-Ra
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.193-194
    • /
    • 2010
  • This study classify the every meshes in Busan metropolitan city, based on the heat density and cooling/heating ratio. As the result of evaluations on the heat density and cooling/heating ratio for the 3289 meshes, the number of meshes which needs more than 2.5 Tcal/mesh.year of heat density is 850(25.8%). The meshes that needs more than district and cooling index 1, which is normally and strongly requested to introduce the district cooling and heating system, is 188(5.7%).

  • PDF

Comparison of system efficiency and thermal analysis about single phase 3-level PFC converter with variation of switching modulation (단상 3레벨 PFC 컨버터의 모듈레이션 기법에 따른 효율비교 및 열해석)

  • Yeo, Si-Jun;Baek, Seunghoon;Cho, Younghoon;Choe, Gyuha
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.229-230
    • /
    • 2017
  • 본 논문은 단상 3레벨 PFC 컨버터에 적용하는 두 가지 모듈레이션 기법에 따른 시스템 효율 및 스위치 발열을 비교하고, 열해석 시뮬레이션을 통한 열 분포에 대한 결과를 기반으로 적절한 방열기법 모색을 위한 근거자료를 제시한다. 제안하는 모듈레이션 기법을 통해, 주 스위치인 SiC MOSFET의 도통손실을 저감하여 시스템 효율을 향상시키며, 스위치에 발생하는 열을 저감시킨다. 앤시스 열해석 시뮬레이션을 통해 이를 확인하고, 실험을 통해 검증한다. 정격부하(5kW)에 대해 약 $27^{\circ}C$의 스위치 온도저감이 이루어졌으며, 전 부하(0.5kW ~ 5kW)에 걸쳐 약 1%의 효율이 향상되었음을 실험을 통해 확인하였다.

  • PDF

Parameter Estimation of the Water Quality model using the Inverse Theory (역산이론을 이용한 수질모형의 매개변수 추정)

  • Cho, Bum-Jun;Cho, Hong-Yeon;Jeong, Shin-Taek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.469-473
    • /
    • 2005
  • 수질모형의 지배방정식에서 정의되는 대표적인 수질매개변수는 유역 및 대기로부터의 오염부하량 퇴적물로부터의 오염물질 용출부하량, 확산계수. 반응계수 등으로 직접적인 관측이 곤란할 뿐만 아니라 많은 관측비용을 필요로 한다. 본 연구에서는 매개변수를 포함한 오염물질 수지방정식을 구성하고, 구성된 선형 연립방정식을 이용함으로써 계산된 농도분포자료와 관측된 시계열 농도분포자료를 이용하여 계산한 질량변화량의 차이를 최소화하는 역산문제를 구성하여 모형의 매개변수를 추정하는 방법을 제시하였다. 이 방법을 이용하여 천수만, 울산만(울산항) 해역에서 관측된 연직방향 농도분포 자료를 이용하여 확산계수 및 대기로부터의 오염부하량, 퇴적물로부터의 오염물질 용출율, 확산$\cdot$반응에 의한 오염물질 변화량 등을 추정하였으며, 추정 매개변수는 시기적으로 변동이 크게 나타났다. 반면, 추정매개변수를 이용한 관측자료와 계산결과를 비교한 결과, RMS 오차는 관측자료 범위의 $5.0\% 이하, 일치지수는 0.95 이상으로 본 방법을 이용한 매개변수 추정결과의 신뢰성은 우수한 것으로 파악되었다.

  • PDF

Prediction of Thermal Load Distribution and Temperature of the Superheater in a Tangentially Fired Boiler (접선 연소식 보일러의 최종 과열기 열부하 분포 및 튜브 온도 예측에 관한 연구)

  • Park, Ho-Young;Sea, Sang-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.478-485
    • /
    • 2008
  • The extreme steam temperature deviation experienced in the superheater of a tangentially fired boiler can seriously affect its economic and safe operation. This temperature deviation is one of the main causes of boiler tube failures. The steam temperature deviation is mainly due to the thermal load deviation in the lateral direction of the superheater. The thermal load deviation consists of several causes. One of the causes is the non-uniform heat flow distribution of burnt gas on the superheater tube system. This distribution is very difficult to measure in situ using direct experimental techniques. So, we need thermal load model to estimate the tube temperature. In this paper, we propose a thermal load distribution model by using CFD analysis and plant data. We successfully predict the tube temperature and the steam flow rate in a final superheater system from the thermal load model and one dimensional heat-flow system analysis. The proposed model and analysis method would be valuable in preventing the frequent tube failure of the final superheater tubes.

차세대 원전의 Mode K 기법에 의한 일일 부하추종운전중 노심 거동

  • 오수열;장종화
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.117-124
    • /
    • 1996
  • 원전의 상용 부하추종운전 능력을 위한 노심 제어기법인 Mode K를 개발하고, 이를 차세대원전의 제1주기 주기초에 적용하여 일일 부하추종운전을 수행할 때의 노심 거동을 ONED94 전산코드로 모사 계산하였다. 계산 결과, 단순하면서도 유연한 형태의 붕산 농도 변화를 수용하면서 제어봉으로 출력분포 및 반응도를 동시에 제어하는 Mode K 제어 논리가 잘 작동하였으며, PbXb운전에 비하여 액체 폐기물 생성량이 30%까지 감소하였다.

  • PDF