A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency (건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구)

  • Kim, Woong-Hoi;Kim, Hyung-Kyu;Lee, Tae-Gyu;Lee, Jae-Hyun;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

A study of geothermal heat dump for solar collectors overheat protection (태양열 집열관 과열방지를 위한 지중열교환기 연구)

  • Hwang, Hyun-Chang;Chi, Ri-Guang;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.616-622
    • /
    • 2016
  • The heating load using solar hot water is lower in summer than in the other seasons. This decreased heating load leads to the overheating solar collectors and related components. To prevent overheating of the solar collectors, air cooling and shading shields were used. On the other hand, it requires additional mechanical components, and reduces the system reliability. The geothermal heat dump system to release the high temperature heat (over $150^{\circ}C$) transferred from the heat pipe solar collectors was investigated in the present study. Research on the heat dump to cool the solar collector is rare. Therefore, the present study was carried out to collect possible data of a geothermal heat dump to cool the solar collector. A helical type geothermal heat exchanger was buried at a 1.2m depth. Experimentally and numerically, the geothermal heat dump was investigated in terms of the effects of parameters, such as the quantity of solar radiation, aperture area of the collector and the mass flow rate. A pipe length of 50m on the geothermal heat exchanger was suitable with a 0.33 kg/s flow rate. The water reservoir was a possible co-operation solution linked to the geothermal heat exchanger.