• Title/Summary/Keyword: 열(물질)전달계수

Search Result 43, Processing Time 0.034 seconds

An Experimental Study on Heat and Mass Transfer Characteristics of the LiBr-Water Solution Film inside a Vertical Tube (수직관내 리튬브로마이드 수용액의 열 및 물질전달 특성에 관한 실험적 연구)

  • 강인석;유승광;이동진;김태진
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.103-108
    • /
    • 1994
  • 리튬브로마이드 수용액이 수직관내면을 따라 액막의 형태로 흘러 내릴때 수증기와의 흡수과정에 대하여 열 및 물질전달 특성을 실험하였다. 실험에서 열 및 물질전달계수는 막레이놀즈수를 30에서 200까지 변화시키면서 실시하였다. 일정한 냉방능력에서 시스템 압력을 변화시켰을 때의 열 및 물질전달계수를 측정하였다. 액막의 열전달계수는 레이놀즈수가 증가함에 따라 감소하였다. 최대 질량유량에서 최적의 막레이놀즈수가 존재하였다.

  • PDF

Heat/Mass Transfer Measurements on a Film Cooled Blade with Naphthalene Saturated Coolant (나프탈렌 포화공기가 분사되는 막냉각 홀을 가진 터빈 블레이드 표면의 열/물질전달 계수 측정)

  • Lee, Dong-Hyun;Rhee, Dong-Ho;Kim, Kyung-Min;Cho, Hyung-Hee;Kim, Beom-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.433-436
    • /
    • 2010
  • In this paper, heat/mass transfer characteristics on a film cooled stationary rotor blade are investigated using the naphthalene sublimation method. A row-speed annular wind tunnel with a single annular turbine stage is used. Three rows of film cooling holes are machined on the leading edge of the test blade. Detailed heat/mass transfer distributions are measured with changing the blowing rate from 1.0 to 2.0. As the blowing ratio increases, overall heat/mass transfer increases and the lower peak formed on the pressure side were disappeared.

  • PDF

Research on Heat and Mass Transfer Coefficient in the Packing Layer With a Solar Desiccant Heating/Cooling System (태양열 데시컨트 냉난방시스템 중 충진층에 있어서의 열 물질전달에 관한 연구)

  • Yohana, Eflita;Choi, Kwang-Hwan;Kim, Bu-Ahn;Kim, Dong-Gyu;Paek, Ki-Dong;Kim, Ji-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.17-24
    • /
    • 2006
  • 최근에 에너지절약 차원에서 종래의 공조방식을 대신할 새로운 냉난방시스템 개발이 요구되고 있는데, 본 논문에서는 태양열 집열기를 이용하는 데시컨트 시스템 중 제습역할을 실질적으로 담당하는 제습기의 충진층 부분에서의 열 및 물질전달에 관한 일련의 해석 결과를 발표하고 있다. 제습과정에서 액체흡수제는 충진층에서 열 뿐만 아니라 물질전달을 수반하게 되는데, 이 결과 건물에 냉방 및 난방효과를 가져다 준다. 따라서 이 충진층의 최적 설계가시스템의 효율을 극대화하기 위해서는 무엇보다도 중요한데, 이를 위해서는 충진층에서의 열 및 물질전달 양상을 규명하여야 한다. 따라서 금번 실험에서는 공기와 액체흡수제와의 접촉면적을 넓히기 위해서 충진재로써 3cm(직경) ${\times}$ 3cm(높이)인 시판중인 플라스틱 재질을 사용하고, 실질적으로 40cm(너비)${\sim}$40cm(깊이)${\times}$40cm(높이)의 충진층을 직접 제작하여 실험을 행하였다. 그 결과, 공기측 열 및 물질전달 계수는 공기 온도와 밀접한 관계를 갖고 있으며, 또한 물질전달계수는 열전달계수와 같은 경향을 보이고 있음을 알 수 있었다.

Experimental Study of Mass Transfer on a Film Cooled Cirular Cylinder Surface (막냉각되는 원봉 표면에의 물질전달에 관한 실험적 연구)

  • 이준식;이택식;이상우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1756-1762
    • /
    • 1991
  • 본 연구에서는 막냉각되는 터빈블레이드에서의 열전달 계수를 측정하기 위하 여 열전달과 물질전달의 상사관계를 이용하였다.터빈블레이드의 선단을 다른 연구 에서와 마찬가지로 원봉으로 모사하였고, 원봉의 표면에 위치하고 있는 1열의 분사홀 로부터 제트가 분사될 때 분사홀 근처 및 그 하류에서의 물질 전달계수를 측정하기 위 해 나프탈렌승화법을 이용하였다. 분사홀 열의 위치를 정체점에서 하류방향으로 이 동시키면서, 물질전달계수의 변화를 연구하였고, 분사율(M=.rho.$_{j}$ U$_{j}$ /.rho.$_{\infty}$ U$_{\infty}$)의 영향도 고찰하였다.

직접 접촉방식 열 및 물질교환 장치의 전달현상(II)

  • 김석현
    • Journal of the KSME
    • /
    • v.25 no.5
    • /
    • pp.413-418
    • /
    • 1985
  • 직접 접촉식 교환장치(이하 직접 교환기라 함)에서 액체의 유통형태의 선택은 매우 다양하며 전달계수 역시 개별적인 상황이나 충전물의 종류에 따라서 달라지므로 일률적으로 제시되지 못 하고 있다. 많은 경우 실험을 통하여 열전달 또는 물질전달계수를 측정하게 되나 개수로, 자유 낙하액체막, 액체분류와 같이 이상화가 가능한 경우, 이러한 전달계수를 구하기 위하여 이론적 또는 반실험적인 해석을 수행하기도 한다. 수많은 관련 연구결과들은 층류유동에 관한 것과 난류유동의 경우로 구분되고(예상되듯이 대부분의 직접교환기의 유통영역은 난류쪽이다), 난류 유통의 해석은 다시 표면갱신이론(surface renewal model), 와류확산계수모델(eddy diffusivity model-macroscopic), 미분형와류모델(differential eddy diffusivity model)로 대별된다. 여기서는 수많은 교환기형태의 자료정리보다 상기와 같이 대별된 액체측 유동영역별로 전달현상해석의 방법을 간단히 정리하고자 한다.

  • PDF

Heat and Mass Transfer in Highly Porous Media (고 다공성 물질에서 열 및 물질전달)

  • 이금배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.685-693
    • /
    • 1990
  • The heat transfer coefficients were calculated numerically to see the effects of radiation around the porous medium put on the flat plate at a distance from the leading edge of flat plate for the two-dimensional laminar flows. To verify the analytical model developed and invoke the heat/mass transfer analogy, an experiment was carried out using naphthalene sublimation technique. From the effects of the wake, Sherwood number is maximum around the region where the porous medium is attached. The theoretical results correspond well with the experimental results at small Darcy number. Permeability of ceramic blocks used for experiment was also measured and the Forchheimer equation is applicable in our measurement range.

Heat Transfer and Friction Characteristics of Louver Fin and Tube Heat Exchangers under Wet Conditions (루버핀-관 열교환기의 습조건에서의 열전달 및 마찰특성에 대한 실험 연구)

  • Kwon, Young Chul;Chang, Keun Sun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • An experimental study was conducted to investigate the effect of a tube row, a fin pitch and an inlet humidity on air-side heat and mass transfer performance of louvered fin-tube heat exchangers under wet conditions. Experimental conditions were varied by three fin pitches, two rows, two inlet relative humidities. Experimental results showed that the heat transfer performance decreased and the friction increased with the decrease of fin pitch, for 2 row heat exchanger. The effect of fin pitch on heat transfer performance was negligible with 3 row heat exchanger. The changes in relative humidity was not affected heat transfer and friction. However, the mass transfer performance was slightly decreased with the increase of relative humidity and with the decrease of fin pitch. The mass transfer performance of the louvered fin-tube heat exchanger decreased with the decrease of the fin pitch and was different according to the number of tube row.

Measurement of Heat (Mass) Transfer Coefficient on the Blade Surfaces of a Linear Turbine Rotor Cascade With a Four-Axis Naphthalene Profile Measuring System (4-축 나프탈렌 승화깊이 측정시스템을 이용한 터빈 블레이드 표면에서의 열(물질)전달계수 측정)

  • Kwon, Hyun-Goo;Lee, Sang-Woo;Park, Byung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.42-47
    • /
    • 2001
  • The heat (mass) transfer characteristics on the blade surface of a first-stage turbine rotor cascade for power generation has been investigated by employing the naphthalene sublimation technique. A four-axis profile measurement system is successfully developed for the measurements of the local heat (mass) transfer coefficient on the curved blade surface. The experiment is carried out at the free-stream Reynolds number and turbulence intensity of $2.09\times10^5$ and 1.2%. The results on the blade surfaces show that the local heat (mass) transfer on the suction surface is strongly influenced by the endwall vortices, but that on the pressure surface shows a nearly two-dimensional nature. The pressure surface has a more uniform distribution of heat load than the suction one.

  • PDF

Prediction on heat and mass transfer coefficients in a packed layer of a regenerator with a solar desiccant cooling system (태양열제습냉방시스템 중 재생기의 충진층 내 열물질 전달계수에 관한 예측)

  • Eflita, Yohana;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.36-42
    • /
    • 2010
  • 본 논문은 태양열이용 냉난방시스템 중에서 실제로 액체흡수제를 재생하는 재생탑 내의 충진층에 있어서의 열 및 물질전달의 실험치와 이론적 해석에 의한 결과치와의 비교를 나타내고 있다.특히 물질전달의 극대화를 위하여 충진층 내에서 공기와 흡수제의 접촉면적을 크게 할 필요가 있는데,이를 위해서 본 실험에서는 직경이 3cm인 플라스틱제 충진재를 사용하였으며, 흡수제로는 저농도의 염화리튬 수용액이 사용 되었다. 충진층 내에서의 최적 높이를 예측하기 위하여 해석의 모델인 실험장치를 직접 제작하여 실험을 수행하였고, 이론 해석에 있어서 체적 열전달을 고려한 정상상태를 모델화하여 해석하였다. 이 결과, 충진층 내에서 실험치와 이론적인 계산치가 잘 일치함을 알 수 있었으며, 충진층의 높이가 2m 이상인 경우에는 높이에 따른 재생량의 차이가 없어서 없음을 알 수 있었다.

Effect of Free Stream Turbulence Intensity on Heat/Mass Transfer Characteristics Around a Film Cooling Hole (주유동의 난류강도가 막냉각홀 주위의 열/물질전달 특성에 미치는 영향)

  • 이동호;김병기;조형희
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.56-63
    • /
    • 1998
  • The present study investigated local heat transfer characteristics around a film cooling hole with variations of free stream turbulence intensity The film cooling jet is injected through a single hole inclined at $30^{\cire}$ to the surface and laterally at $45^{\cire}$ for the blowing rates of 0.5, 1.0 and 2.0. Turbulence generating grids are used at upstream of the film cooling hole to change the turbulence intensity of free stream. Free stream turbulence intensity without grids is 0.5%. Two different turbulence generating grid is installed at different at locations upstream of the film cooling hole so that turbulence intensity of free stream varies from 3% to 10%. The naphthalene sublimation technique has been employed to determine local heat/ mass transfer coefficients. With low free stream turbulence intensity, heat/mass transfer augmented area by coolant or free stream is distinguished evidently. However, when free stream turbulence intensity is high, heat transfer is enhanced in all region and heat transfer enhanced regions are not clearly divided due to vigorous mixing of coolant and free stream. The peak values of heat/mass coefficients are decreased and the distributions of heat/mass transfer coefficients are more uniform with high turbulence intensity. The effect of turbulence intensity on heat transfer characteristics is more evident as blowing rate is higher.

  • PDF