• Title/Summary/Keyword: 연소영역

Search Result 490, Processing Time 0.026 seconds

Study on Full Load Operation Characteristics and Thermal Efficiency of 1.4L Turbo CNG SI Engine (1.4L급 터보 CNG SI엔진의 전부하 운전 특성 및 열효율에 대한 연구)

  • Bae, Jong-Won;Park, Cheol-Woong;Lee, Jeong-Woo;Kim, Yong-Rae;Kim, Chang-Gi;Lee, Sun-Youp;Lee, Jin-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.34-39
    • /
    • 2018
  • Natural gas is attracting attention as an alternative to existing fossil fuels. Natural gas has a high octane number. Therefore, knocking does not occur even if the compression ratio is increased, so that the thermal efficiency and the output can be improved. And it is relatively easy to apply the natural gas supply system to the internal combustion engine hardware system. In this study, a gasoline direct injection turbo engine was converted into a natural gas port injection type turbo engine. Therefore, the combustion and performance of the engine are measured and compared comprehensively in the region where the turbo operates.

The Volcanic Eruption Velocity and Tumulus of Jeju Island Controlled by the Natural Intelligence (자연 지능 제어에 의한 제주도의 화산 폭발 속도와 튜물러스)

  • Lee, Seong kook;Lee, Moon Ho;Kim, Jeong Su
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.493-499
    • /
    • 2022
  • This paper reports the results of the eruption of a volcano on Jeju Island at a certain rate, and the tumulus formed after the eruption and the basalt that erupted from the middle of Mt. Halla washed up to the sea. We analyzed the speed when basalt underground magma breaks through the neutral zone on the ground with an absolute temperature of about 1000K and explodes at an absolute temperature of 1200K at an altitude of 1950m. The density of combustion gas becomes smaller than the surrounding air due to the plume volcanic eruption, which is the heat flow of the flame column due to buoyancy, and buoyancy is generated and an updraft is formed. Flame pillars are classified as continuous, intermittent, and buoyant flame zones. As the speed of the flame pillar of Mt. Halla (1950m) falls from the highest point it has risen, potential energy is converted into kinetic energy and is caused by the flow of fluid, solving these two equations equal, the volcanic eruption velocity is 87.5 m/s. At this time, the density of magma is inversely proportional to the temperature. Geomunoreum (456m) had an explosion speed of 42.6m/s.

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

Process Design of Carbon Dioxide Storage in the Marine Geological Structure: II. Effect of Thermodynamic Equations of State on Compression and Transport Process (이산화탄소 해양지중저장 처리를 위한 공정 설계: II. 열역학 상태방정식이 압축 및 수송 공정에 미치는 영향 평가)

  • Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.4
    • /
    • pp.191-198
    • /
    • 2008
  • To design a reliable $CO_2$ marine geological storage system, it is necessary to perform numerical process simulation using thermodynamic equation of state. $CO_2$ capture process from the major point sources such as power plants, transport process from the capture sites to storage sites and storage process to inject $CO_2$ into the deep marine geological structure can be simulate with numerical modeling. The purpose of this paper is to compare and analyse the relevant equations of state including ideal, BWRS, PR, PRBM and SRK equation of state. We also studied the effect of thermodynamic equation of state in designing the compression and transport process. As a results of comparison of numerical calculations, all relevant equation of state excluding ideal equation of state showed similar compression behavior in pure $CO_2$. On the other hand, calculation results of BWRS, PR and PRBM showed totally different behavior in compression and transport process of captured $CO_2$ mixture from the oxy-fuel combustion coal-fired plants. It is recommended to use PR or PRBM in designing of compression and transport process of $CO_2$ mixture containing NO, Ar and $O_2$.

  • PDF

Effect of SO2 on NOx Removal Performance in Low Temperature Region over V2O5-Sb2O3/TiO2 SCR Catalyst Washcoated on the Metal Foam (저온영역에서 메탈폼에 코팅된 V2O5-Sb2O3/TiO2 SCR 촉매의 NOx 저감성능에 미치는 SO2 영향에 관한 연구)

  • Na, Woo-Jin;Park, Young-Jin;Bang, Hyun-Seok;Bang, Jong-Seong;Park, Hea-Kyung
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.132-138
    • /
    • 2016
  • The emission of SO2 is inevitable in case of combustion of most fossil fuels except LNG in commercial power plant which has a bad effect on the durability of SCR catalyst. To develop a low temperature SCR catalyst which has a high NOx removal performance and excellent durability to SO2, V2O5/TiO2 catalysts were prepared by coating on the metal foam substrate with the impregnation amount of Sb2O3 as promotor. This study has evaluated the NOx removal performance and the durability to SO2 on a laboratory scale atmospheric reactor and analyzed the properties of the prepared catalysts by means of porosimeter, BET, SEM (scanning electron microscope), EDX (energy dispersive x-ray spectrometer), XPS (X-ray photoelectron spectroscopy). It was found that the surface area of catalyst increased with the impregnation amount of Sb2O3 and the NOx removal performance showed the highest value at the 2 wt% impregnation of Sb2O3. This results was considered to be due to the optimum active site on the catalyst surface. And also, Sb2O3 impregnated catalysts presented that NOx removal performance was maintained despite the exposure to SO2 for 5 hours. Therefore it was confirmed that metal foam SCR catalyst for low temperature could be manufactured with the optimum control of Sb2O3 impregnation according to the SO2 presence or not.

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

Effect of Varying Excessive Air Ratios on Nitrogen Oxides and Fuel Consumption Rate during Warm-up in a 2-L Hydrogen Direct Injection Spark Ignition Engine (2 L급 수소 직접분사 전기점화 엔진의 워밍업 시 공기과잉률에 따른 질소산화물 배출 및 연료 소모율에 대한 실험적 분석)

  • Jun Ha;Yongrae Kim;Cheolwoong Park;Young Choi;Jeongwoo Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.52-58
    • /
    • 2023
  • With the increasing awareness of the importance of carbon neutrality in response to global climate change, the utilization of hydrogen as a carbon-free fuel source is also growing. Hydrogen is commonly used in fuel cells (FC), but it can also be utilized in internal combustion engines (ICE) that are based on combustion. Particularly, ICEs that already have established infrastructure for production and supply can greatly contribute to the expansion of hydrogen energy utilization when it becomes difficult to rely solely on fuel cells or expand their infrastructure. However, a disadvantage of utilizing hydrogen through combustion is the potential generation of nitrogen oxides (NOx), which are harmful emissions formed when nitrogen in the air reacts with oxygen at high temperatures. In particular, for the EURO-7 exhaust regulation, which includes cold start operation, efforts to reduce exhaust emissions during the warm-up process are required. Therefore, in this study, the characteristics of nitrogen oxides and fuel consumption were investigated during the warm-up process of cooling water from room temperature to 88℃ using a 2-liter direct injection spark ignition (SI) engine fueled with hydrogen. One advantage of hydrogen, compared to conventional fuels like gasoline, natural gas, and liquefied petroleum gas (LPG), is its wide flammable range, which allows for sparser control of the excessive air ratio. In this study, the excessive air ratio was varied as 1.6/1.8/2.0 during the warm-up process, and the results were analyzed. The experimental results show that as the excessive air ratio becomes sparser during warm-up, the emission of nitrogen oxides per unit time decreases, and the thermal efficiency relatively increases. However, as the time required to reach the final temperature becomes longer, the cumulative emissions and fuel consumption may worsen.

The Simultaneous Absorption Rate of CO2/SO2/NO2 from Flue Gas with Aqueous Alkanolamine Solutions (알카놀아민 수용액을 이용한 연소배가스 중의 CO2/SO2/NO2 동시 흡수속도에 관한 연구)

  • Seo, Jong-Beom;Choi, Won-Joon;Kim, Jae-Won;Choi, Bong-Wook;Oh, Kwang-Joong
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.639-645
    • /
    • 2009
  • In this study, alkanolamine was used to achieve high absorption rates for $CO_2$ as suggested at several literatures. The absorption rates of aqueous AMP and MEA solutions with $CO_2$, $SO_2$, $NO_2$ were measured using a stirredcell reactor. The reaction rate constants were determined from the measured absorption rates. The performances were evaluated under various operating conditions. As a result, the reactions with $SO_2$, $NO_2$ into aqueous AMP and MEA solutions were classified as an instantaneous reaction respectively. The absorption rates increased with increase of the reaction temperature and the concentration of absorbents. The simultaneous absorption rate of $CO_2/SO_2/NO_2$ into 3, 5, 10 wt.% MEA at various pressure of $CO_2/SO_2/NO_2$, was more increased 14~20% than AMP solution. We investigated the effect of $SO_2$ and $NO_2$ on the simultaneous absorption of $CO_2/SO_2/NO_2$ from a flue gas. The performances were evaluated under various operating conditions in order to investigate the absorption characteristic.

Temperature Prediction of Cylinder Components in Medium-Speed Diesel Engine Using Conjugate Heat Transfer Analysis (복합 열전달 해석을 이용한 중속 디젤엔진 실린더 부품 온도 분포 예측)

  • Choi, Seong Wook;Yoon, Wook Hyoen;Park, Jong Il;Kang, Jeong Min;Park, Hyun Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.781-788
    • /
    • 2013
  • Predicting the engine component temperature is a basic step to conduct structural safety evaluation in medium-speed diesel engine design. Recent trends such as increasing power density and performance necessitate more effective thermal management of the engine for achieving the desired durability and reliability. In addition, the local temperatures of several engine components must be maintained in the proper range to avoid problems such as low- or high-temperature corrosion. Therefore, it is very important to predict the temperature distribution of each engine part accurately in the design stage. In this study, the temperature of an engine component is calculated by using steady-state conjugate heat transfer analysis. A proper approach to determine the thermal load distribution on the thermal boundary area is suggested by using 1D engine system analysis, 3D transient CFD results, and previous experimental data from another developed engine model. A Hyundai HiMSEN engine having 250-mm bore size was chosen to validate the analysis procedure. The predicted results showed a reasonable agreement with experimental results.

비증착 방법에 의한 사용후 핵연료의 EPMA 분석

  • 정양홍;송웅섭;김도식;김희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.353-354
    • /
    • 2004
  • 사용후 핵연료의 조성을 분석하거나 또는 반사전자상과 2차 전자상 등으로 시료를 관찰하기 위해서는 핫셀(Hot cell)에 증착기(coater)를 설치하여 시료표면을 전도성 물질인 탄소 등으로 증착시켜야 한다. 그러나 원격조정기를(manipulator)를 이용하여 수행되는 핫셀에서의 증착작업은 사용후 핵연료 시험의 선진분석기술을 갖고 있는 원자력 선진국에서도 핫셀내에 설치되어 있는 증착기의 탄소봉을 교체하는 작업과 진공장치의 성능 유지가 까다로워 시료표면에 균질하게 전도성 물질을 증착시키는 작업에 많은 어려움을 겪고 있다. 본 연구는 통상적으로 이용되는 증착기를 사용하지 않고 Silver Paint를 사용하여 사용후 핵연료를 분석할 수 있는 새로운 방법에 대한 연구를 수행하였다. 산화물 핵연료는 전기전도도가 매우 낮아($3{\times}10^{-1}~4{\times}10^{-8}/ohm{\cdot}cm$)입사된 전자의 이동이 원활하지 못해 일어나는 들뜸(Charging)현상이 발생한다. 그러나 Silver Paint 에 사용후 핵연료를 접착하면 모세관(capillary)현상에 의해 시료 주위와 핵연료의 결정립계로 Silver가 스며들어 입사된 전자의 이동이 원활해져 전도성이 극히 낮은 시료의 분석이 가능하게 된다. 본 시험에 사용된 EPMA는 (Electron Probe Micro Analyzer, SX-50R, CAMECA, Paris, France) 고 방사능을 띤 조사 핵연료의 시험을 수행할 수 있도록 기기의 적절한 부위에 납과 텅스텐으로 차폐되어 시편의 방사능 세기가 $3{\times}10^{10}Bq$까지 시험 가능한 기기이다. 그림 1은 JAERI 에 설치 운영중인 증착기 설비 사진이다. 그림에서 핫셀에 설치된 증착기의 진공을 유지하기 위해 핫셀 벽을 관통하여 증착기 본체까지 연결된 배출관의 형상과 복잡한 주변장치들을 볼 수 있다. 그림 2는 비조사 핵연료 시편을 Silver Pain떼 접착한 사진이다. 그림은 시료주위와 시료 표면까지 Silver Paint가 도포된 모습을 보여주고 있다. 상용발전소에서 연소도가 50,000 Mwd/tU인 사용후 핵연료를 상기와 같은 방법으로 만든 시편의 표면을 관찰한 사진을 그림 3~8에 나타내었다. 그림 3은 핵연료 중앙부위의 결정립을 나타낸 그림이다. Silver Paint만으로 접착한 시료의 표면관찰 및 정량분석이 그림에서 보듯이 가능함을 확인하였다. 그림 4는 사용후 핵연료시료를 중앙부위에서 가장자리까지를 다섯 부위로 나누어 그 중 중앙부위(1/5) 지점의 입계 및 형상을 관찰한 사진이다. 결정립의 크기가 다른 부위보다 상대적으로 크고, 결정립에 생성된 기공이 발달되어 있음을 볼 수 있다. 그림 5와 6과 7은 중심부위와 rim부위 사이 지점을 관찰한 사진으로서 결정립과 기공의 분포가 비슷한 형상을 나타내고 있음을 관찰할 수 있었다. 그림 8은 rim 부위 사진으로 전형적인 rim 영역 현상을 관찰할 수 있었다. 표 1은 그림 2와 같이 비조사 산화물 핵연료를 Silver Paint로 접착한 시편을 정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.

  • PDF