• 제목/요약/키워드: 연성 모멘트 골조

검색결과 58건 처리시간 0.022초

철근 콘크리트 보통 모멘트 골조 기둥의 거동평가 (Seismic Behaviors of OMRCF Columns)

  • 한상환;이리형
    • 콘크리트학회논문집
    • /
    • 제14권2호
    • /
    • pp.199-206
    • /
    • 2002
  • The objective of this study is to investigate the seismic behavior and evaluate structural performance of columns in Ordinary Moment Resting Concrete Frames (OMRCF). For this purpose 3 story OMRCF building was designed and detailed in compliance to ACI 318 (1999). Only gravity load is considered for the design. It is important to note that details strongly relate to the structural performance. The 1st story columns in the 3 story building are considered in this study since 다lese columns shall resist the largest axial and lateral forces during an earthquate. Four test specimens were made for representing the upper part and lower part of exterior and interior columns. All specimens are two-third scale. Based on the test results this study estimates deformation, ductility, strength, and energy absorption capacities as well as plastic hinge length.

대표응답을 이용한 건축구조물의 비선형 지진응답 분석 및 내진성능평가 (Evaluation of Nonlinear Seismic Performance Using Equivalent Responses of Multistory Building Structures)

  • 이동근;최원호
    • 한국지진공학회논문집
    • /
    • 제5권6호
    • /
    • pp.65-76
    • /
    • 2001
  • 지진하중을 받는 구조물의 시스템 연성요구도 산정과 비선형 지진거동 예측에 대한 연구는 성능에 기초한 내진설계에서 구조물의 내진성능을 평가하는데 있어서 매우 중요한 분야이다. 본 연구에서는 철골 모멘트골조 구조물에 대하여 비선형 시간이력해석에 의한 비선형 지진응답과 시스템 연성요구도를 산정하고, 그 결과를 비선형 정적해석을 이용한 능력스펙트럼법과 비교하였다. 예제구조물에 대한 내진성능평가는 ATC-40에서 제시된 능력스펙트럼법과 본 연구에서 제안한 다자유도 시스템으로부터 직접 산정된 대표응답을 이용한 개선된 능력스펙트럼법과 비교하였다. 본 연구에서 제안된 방법의 정확성과 타당성은 ATC-40에서 제시된 방법과 제안된 방법에 의한 결과를 비선형 시간이력해석에 의한 비선형 지진응답과 비교함으로써 검증하였다.

  • PDF

비좌굴 가새를 이용한 스태거드 트러스 시스템의 내진성능향상 (Seismic Improvement of Staggered Truss Systems using Buckling Restrained Braces)

  • 김진구;이준호
    • 한국지진공학회논문집
    • /
    • 제10권2호
    • /
    • pp.11-19
    • /
    • 2006
  • 본 연구에서는 4층, 10층, 30층 스태거드 트러스 시스템 (STS)의 비탄성 정적해석에 의한 하중-변위 관계와 비탄성거동을 분석하고, 그 결과를 바탕으로 STS의 내진성능을 평가하였다. 또한 동일한 규모의 모멘트골조 및 가새골조의 거동과 비교함으로써 STS의 횡력 저항 능력을 파악하였다. 해석결과에 따르면, STS는 일반적으로 적용되는 구조시스템에 비하여 비교적 만족할 만한 내진성능을 보유하는 것으로 나타났다. 그러나 중층 이상의 STS에 있어서는 상대적으로 강성이 작은 비렌딜 패널 상.하현재에 소성변형이 발생한 후 인접한 수직 가새가 항복함으로써, 다른 층으로 소성변형이 전이되지 못하여 약층의 형성에 의한 취성적인 거동을 보인다. 그러므로 스태거드 트러스 시스템의 연성능력을 확보하기 위해서는 비렌딜 패널의 수직 가새를 보강하여 비렌딜 패널 상하현재에 발생한 소성변형을 다른 층의 비렌틸 패널로 유도하는 것이 필요하다.

기둥-보 용접접합부의 보단부 스캘럽형상과 탄소성 거동에 관한 실험적 연구 - 600MPa(SM570TMC)의 경우 - (Study on Elasto-Plastic Behavior of Column to Beam Connection with 600MPa High Performance Steel(SM 570 TMC))

  • 김종락;김성배;권준엽
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.691-700
    • /
    • 2008
  • 최근 건축구조물의 구조는 다양한 형태의 복잡한 건축물이 구현되고 있다. 이러한 건축구조물의 복합 다양성은 수평저항력에 효과적 으로 저항하기 위해 강재와 접합부의 요구성능이 점차 중요시되고 있다. 접합부는 형상의 불연속과 응력집중 및 다축응력 등이 발생되는 부분으로 골조전체의 변형능력에 큰 영향을 미치고 강성과 인성을 결정하는 중요부위이다. 본 연구에서는 고강도 고성능강 적용에 대한 인성평가를 위해 구조체의 기둥-보 접합부를 빌트업 H형강의 T형 기둥-보 용접접합부로 제작하여 실대실험을 수행하였다. 실험변수는 응력집중 및 형상의 불연속이 발생되는 보 스캘럽을 중심으로 논스캘럽(Non-Scallop)과 종래형 스캘럽, 개량형 스캘럽으로 제작하여 스캘럽 형상이 접합부의 인성에 미치는 영향과 고강도 고성능강의 건축구조물 적용성을 평가하였다. 기존의 기둥-보 용접접합부에 대한 평가방법을 기초로 최근 개발된 고강도 고성능강의 초고층 건축물 적용을 위한 내진설계 자료를 제시하였다.

고강도 RC 보-기둥 접합부의 비탄성 거동에 대한 슬래브의 영향 (Slab Effect on Inelastic Behaviors of High Strength RC Beam-Column Joints)

  • 장극관;김윤일;오영훈
    • 콘크리트학회지
    • /
    • 제9권2호
    • /
    • pp.167-177
    • /
    • 1997
  • 모멘트 연성골조의 접합부와 기둥은 적절한 에너지흡수 능력과 구조물의 횡붕괴를 방지하기 위하여 탄성적으로 거동해야 하며, "강한 기둥-약한 보"의 설계개념을 채택하고 있다. 접합부는 골조구조의 취약부분으로 인정되고 있지만 부재설계에서는 접합부를 구성하는 보와 기둥에 의해서 접합부의 치수가 결정되기 때문에 접합부가 부담해야 하는 하중조건과 보강방법을 결정하는데에 어려움이 있다. 또한 콘크리트의 고강도화, 경량화에 의해 부재단면은 작아지게 되고 상대적으로 철근량은 늘어나게 되므로 접합부 영역의 응력부담은 이전보다 훨씬 높아지게 되었다. 따라서 접합부의 적절한 구조성능 확보 및 시공상의 문제점을 개선하기 위하여 접합부의 설계 및 상세에 특별한 주의가 필요하다고 할 수 있다. 이에 본 연구에서는 슬래브의 기여도를 고려한 접합부의 적절한 보강방법을 제시하기 위한 기초자료로서 $\frac{2}{3}$의 실물크기로 4개의 고강도 콘크리트 보-기둥 접합부를 제작하고, 반복하중 실험을 수행하였다.실험을 수행하였다.

소규모 철근콘크리트 모멘트골조 건축물의 초과강도, 연성도 및 반응수정계수 (Over-Strength, Ductility and Response Modification Factor of Small-Size Reinforced Concrete Moment Frame Buildings)

  • 김태완;추유림;박홍근;신영수
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.145-153
    • /
    • 2016
  • Small-size buildings are not designed by professional structural engineers in Korea. Therefore, their seismic performance can not be exactly estimated because their member sizes and reinforcement may be over- or under-designed. A prescriptive design criteria for the small-size buildings exists, but it also provides over-designed structural members since structural analysis is not incorporated, so it is necessary to revise the prescriptive criteria. The goal of this study was to provide an information for the revision, which is seismic performance and capability of small-size reinforced concrete moment frame buildings. For the study, the state of existing small-size reinforce-concrete buildings such as member size and reinforcement was identified by investigating their structural drawings. Then, over-strength, ductility and response modification factor of the small-size reinforced concrete moment frame buildings were estimated by analytical approach along with seismic performance check. The result showed that they possess moderate over-strength and ductility, and may use slightly increased response modification factor.

강판과 가새로 보강된 무량판 구조물의 내진 성능평가 (Seismic Performance Evaluation of Flat Plate Structures Retrofitted with Steel Plates and Braces)

  • 신우승;김진구
    • 한국전산구조공학회논문집
    • /
    • 제21권5호
    • /
    • pp.451-458
    • /
    • 2008
  • 본 논문에서는 중 약진 지역에서 중력 저항시스템인 중간 모멘트골조로 설계된 3층, 6층 RE 플랫플레이트 구조물을 KBC 2005를 만족하도록 RC구조물에 강판과 가새/ BRB 등의 보강방법을 적용하여 보강하고, 내진성능을 평가하여 보강 효과를 검증하였다. 비탄성 정적해석과 동적해석 결과에 따르면 내진 보강된 구조물은 강도와 강성이 크게 향상된 것으로 나타났다 특히 기둥을 철판으로 보강한 경우 슬래브를 철판으로 보강하여 조기 뚫림 전단파괴를 방지함으로써 강도를 크게 향상할 수 있다. BRB로 보강된 구조물은 Brace로 보강된 구조물보다 다소 연성적 거동을 보였으며, 그 효과는 3층 모델에서 현저하게 나타났다.

U형 강봉을 사용한 PC 계단 접합부 개발 (Development of Improved PC Stair Connections Using U-Rods)

  • 장극관;서대원;천영수
    • 토지주택연구
    • /
    • 제2권4호
    • /
    • pp.509-516
    • /
    • 2011
  • 프리캐스트 콘크리트는 현장작업을 최소화하고 공사품질을 보장할 수 있으며 공사기간을 단축시킬 수 있는 장점을 갖고 있다. 특히 계단실의 경우 재래식 거푸집을 사용할 경우 골조공사의 품질저하와 다수의 인력투입에 따른 생산성의 저하 및 시공의 어려움 등의 문제점이 있다. 본 연구에서는 PC 계단 접합부 상세를 개발하고, 제안한 접합부의 일체성확보와 사용성 및 안전성을 검증하기 위해 구조성능실험을 수행하였으며, 단순 핀접합 실험체에 비해 구속도의 증가, 내력, 강성 및 연성의 증가를 확인할 수 있었다.

웨브 개구부를 갖는 철골 보-기둥 접합부의 내진 성능에 관한 연구 (Behavior of Reduced Beam Section Connectios with Web Openins)

  • 박종원;강승민;황인규;강태경;권기주
    • 한국강구조학회 논문집
    • /
    • 제13권4호
    • /
    • pp.395-405
    • /
    • 2001
  • 보-기둥 접합부의 내진성능을 향상시키기 위해 소성힌지의 발생위치를 보의 내부로 유도한 철골 모멘트 접합부에 대해 실험연구를 수행하였다. 이를 위해 보의 단면을 감소시키는 방안으로는 dogbone 접합부에서 처럼 플랜지를 감소시키는 대신에 웨브에 개구부를 설치하였다. 본 연구에서는 개구부의 형상 및 크기를 변수로 하여 총 4개의 실제 크기의 시험체에 대해 반복하중 실험을 수행하였다. 4개 시험체 모두 기둥은 $H-458{\times}417{\times}30{\times}50$, 보는 $H-792{\times}300{\times}14{\times}22$를 사용하였다. 실험결과 웨브 개구부를 이용한 접합부는 강진지역에서 철골 모멘트 연성골조에 요구되는 0.04 rad.의 총회전각을 발휘할 수 있는 것으로 나타났다.

  • PDF

RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대(實物大) 시험 (Cycllic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections)

  • 이철호;전상우;김진호
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.557-566
    • /
    • 2002
  • 본 논문은 4개의 철골모멘트 접합부에 대한 반복재하 실물대(實物大) 실험결과를 요약한 것이다. 주요 실험변수는 기둥과 보의 접합방식 (볼트접합 대 용접) 및 패널존의 강도 (강한 패널존 대 중간강도 패널존)이다. 중간 패널존 강도를 갖는 시험체는 패널존과 RBS 영역 모두에서 균형잡힌 방식으로 에너지가 소산되도록 고려하여 설계된 것으로 패널존 보강비용을 줄이고자 시도한 경우이다. 보웨브가 용접으로 접합된 경우의 시험체들은 특별연성모멘트골조에 요구되는 충분한 접합부 회전성능을 보여 주었지만, 웨브를 볼트로 접합한 시험체들은 스캘럽을 가로지르는 보플랜지의 조기 취성파괴로 인해 열등한 내진성능을 노출하였다. 보웨브를 볼트로 접합하면 비용을 줄일 수 있으나 원래 보단면의 전소성모멘트를 기둥에 전달하기 어려운 것으로 나타났다. 본 연구에서 적용된 것과 같이 양질의 용접시공에 의해 일단 그루브 용접부 자체의 취성파괴 문제가 해결되고 나면, 용접접근공내에 위한 보플랜지 모재의 파단이 다음의 문제로 대두됨을 알 수 있다. 용접접근공 내의 보 플랜지 파단문제를 역학적인 측면에서 이해하는데 도움이 되는 해석적 연구도 수행되었다.