Seismic-performance Experiments of Circular Shear Piers Considering Effects of Rebar Corrosion, Lap splice and Axial Load (철근부식, 겹침이음 및 축하중의 영향을 고려한 원형 전단 교각의 내진성능실험)

  • Lee, Soo-Hyung;Lee, Seung-Geon;Lee, Hyerin;Hong, Kee-Jeung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.143-153
    • /
    • 2021
  • The corroded pier that has corrosion of the tranverse steel, main steel and lapsplice directly affects the seismic performance. The corrosion of the tranvese and main steel directly reduce the shear strength and bendig strength. If steel corrosion occurs in lap splice, the flexural strength and flexibility of existing corroded pier that are not seismic design are significantly reduced. In addition, as the axial force acting on the pier increase the shear strength. Considering these effects. In this stuydy, we cosidered steel corrosion, lap splice and axial force, for a reasonable evaluation of seismic-performance. It is confirmed that flexular failure occurs at pies where shear failure is expected to occur due to corrosion of reinforcement. These failure modes and their reason are analyzed, and necessary considerations are presented for seismic reinforcement.

Evaluation of Structural Performance of Precast Prefabricated Bridge Column using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 조립식 교각의 성능 평가)

  • Chung, Chul-Hun;Yun, Yeon-Suk;Whang, Eun-Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.383-390
    • /
    • 2008
  • A Precast Prefabricated Bridge Column using steel tube and prestressing bar was proposed for the application of precast method on substructure. A column specimen designed by the proposed bridge column system was made and performed a quasi-static test. The failure mode appeared to be a flexural failure and there is no damage on column segment connection. And it is good use of the self-centering ability by prestressing force. Test results showed that a column specimen satisfy the earthquake specification, and the structural stability was verified. Nonlinear finite element analysis was performed and compared with the test results. Force-displacement relation and location of crack from the analysis results were compared with the test results and it agreed well. The quantitative analysis was also performed by a parametric study using this modeling technique.

Behaviour of One-Way Concrete Slabs Reinforced with Fiber Reinforced Polymer (FRP) Bars (FRP 보강근을 주근으로 사용한 일방향 콘크리트 슬래브의 거동)

  • Seo, Dae-Won;Han, Byum-Seok;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.763-771
    • /
    • 2007
  • Over the last few decades, many researches have been conducted in order to find solution to the problem of corrosion in steel reinforced concrete. As a result, methods such as the use of stainless steel bars, epoxy coatings, and concrete additives, etc., have been tried. While effective in some situations, such remedies may still be unable to completely eliminate the problems of steel corrosion. Fiber reinforced polymer (FRP) elements are appealing as reinforcement due to some material properties such as high tensile strength, low density, and noncorrosive. However, due to the generally lower modulus of elasticity of FRP in comparison with the steel and the linear behavior of FRP, certain aspects of the structural behavior of RC members reinforced with FRP may be substantially different from similar elements reinforced with steel reinforcement. This paper presents the flexural behavior of one-way concrete slabs reinforced with FRP bars. They were simply supported and tested in the laboratory under static loading conditions to investigate their crack pattern and width, deflections, strains and mode of failure. The experimental results shows that behavior of the FRP reinforced slabs was bilinearly elastic until failure. Also, the results show that the FRP overreinforced concrete beams in this study can be safe for design in terms of deformability.

Inelastic Behavior of Post-tensioned Wide Beam System with different Reinforcement ratios within Column core (포스트텐션을 도입한 넓은 보에서 기둥 폭 내부에 배근된 보강재의 정착비에 따른 비탄성 거동 평가)

  • Choi Yun-Cheul;Lim Jae-Hyung;Moon Jeong-Ho;Lee Li-Hyung;Kwon Ki-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.85-94
    • /
    • 2005
  • Post-tensioned Precast concrete System(PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with floor concrete cast on the PC shell beam and post-tensioning. The purpose of this paper is to evaluate the response of PPS interior beam-column joint subjected to cyclic lateral loading. To this end, an experimental investigation was performed with three half-scale specimens of interior connection. The design parameters are the amount of beam reinforcement placed inside the joint core. The test results showed that cracks were distributed well without my significant degradation of strength and ductility. Also, it was found that the prestressing may affect to alter the torsional crack angle. And the specimens sufficiently resist up to limiting drift ratio of 0.035 in accordance with the provisional by ACl of acceptance criteria for concrete special moment frames.

Satellite finite element model updating for the prediction of the effect of micro-vibration (미소진동 영향성 예측을 위한 인공위성 유한요소모델 보정)

  • Lim, Jae Hyuk;Eun, Hee-Kwang;Kim, Dae-Kwan;Kim, Hong-Bae;Kim, Sung-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.692-700
    • /
    • 2014
  • In this work, satellite FE (finite element) model updating for the prediction of the effect of micro-vibration is described. In the case of satellites launched in low earth orbit, high agility and more mission accomplishments are required by the customer in order to procure many images from satellites. To achieve the goal, many mechanisms, including high capacity wheels and antennas with multi-axis gimbals have been widely adopted, but they become a source of micro-vibration which could significantly deteriorate the quality of images. To investigate the effect due to the micro-vibration in orbit on the ground, a prediction is conducted through an integrated model coupling the measured jitter sources with FE (finite element) model. Before prediction, the FE model is updated to match simulation results with the modal survey test. Subsequently, the quality of FE model is evaluated in terms of frequency deviation error, the resemblance of mode shapes and FRFs (frequency response functions) between test and analysis.

Automotive Active Suspension Design using LQG/LTR method (LQG/LTR 설계방법을 이용한 자동차 현가장치 능동제어)

  • 박봉철;황재혁
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.86-92
    • /
    • 1993
  • 자동차의 현가장치에 대한 능동제어연구는 국내외적으로 활발히 진행되어 왔다. 수동식현가장치는 단순히 스프링과 감쇠기로 차체의 진동을 수동 제어 하므로 성능 향상에 한계가 존재하게 된다. 수동식 현가장치가 강성계수와 감쇠계수를 조절함으로써 차체로 들어오는 진동을 억제하는 반면, 능동식제 어는 보통 유압을 이용하여 효율적으로 차체에 들어오는 진동을 억제시키게 된다. 일반적으로 자동차가 능동현가장치 설계시 요구되는 사항은 탑승자의 승차감, 조종성, 현가장치의 공간확보 문제, 경제성(제어력), 실제적으로 자동 차에 적용할 수 있는 능동제어기법인가 하는 문제이다. 자동차 능동식 현가 장치는 보통 1/4 car (2자유도계), Full-car 모델 (7자유도계) 등으로 모델링 을 하여 능동제어기를 설계한다. 1/4 car 모델의 특징은 해석이 비교적 단순 하고 현가장치의 동적거동을 이해하는데 유용하고 실험을 하거나 실제 자동 차에 적용하기 쉬운 반면에 Full-car 모델에 비해 제어력의 효율이 떨어진다 는 단점이 있다. 그 이유는 1/4 car 모델은 차체의 동역학적 특성을 고려하 여 설계하지 않았기 때문에 4개의 독립현가차축에서는 오직 그 현가축방향 으로 발생하는 수직방향의 진동만을 제어하기 때문이다. 따라서 동역학적 역 성에 기인하는 운동을 제어하는 비효율적인 제어력이 공급된다는 단점을 갖 는다. 이에 비해 full-car 모델은 주행모드(수직, 롤링, 피칭운동)간의 연성을 고려하여 제어기를 설계할 수 있기 때문에 1/4 car 모델에 비해 제어력의 효 율이 높다는 장점이 있는 반면에 모델이 수학적으로 복잡하므로 제어력을 구하는데 계산량이 많고, 실제 자동차에 적용하기에 복잡하다는 단점을 갖고 있다. 따라서 본 논문에서는 쉽게 실험할 수 있고, 실용화할 수 있는 1/4 car 모델에 대하여 능동제어기를 설계하여 실제자동차에 능동제어기를 적용할 때 참고가 될 수 있도록 하였다. 자동차는 저주파영역의 밴드통과필터 역할 을 하므로 저주파에서의 성능, 특히 탑승자가 민감하게 느끼는 0.5Hz - 10Hz 부근의 주파수성능은 승차감, 조종성에 상당히 중요하다. 이에 본 논문 에서는 0.5Hz - 10Hz 부근의 승차감, 조종성의 향상에 초점을 두고 차체의 속도를 출력변수로 한 LQG/LTR 제어기를 설계하였다. LQG/LTR 설계기법 은 안정도-강인성이 좋은 체계적인 설계기법으로서 전 상태를 측정할 필요 가 없으므로 실제 적용시 효과적이다. 또한 자동차의 제원의 변화에 대한 고 유치의 민감도해석과 새로운 개념으로 안정도-강인성(Robustness)해석을 하 여 수동시스템과 능동시스템의 강인성을 비교하였다.

  • PDF

Experimental Evaluation of the Flexural Behavior of SY Permanent Steel Form for RC Beam and Girder (SY 비탈형 보 거푸집의 휨 거동에 대한 실험적 고찰)

  • Bae, Kyu-Woong;Boo, Yoon-Seob;Shin, Sang-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.11-21
    • /
    • 2022
  • Currently, in the domestic construction industry, the free web method has been emerging as a potential solution to the shortage of skilled workers due to the prolonged COVID-19 crisis, as it helps in securing economic feasibility through shortening the construction period and reducing labor costs. To consider one part of the construction method, in this study, the bending behavior according to the load was evaluated for the SY slope-type beam formwork, which was manufactured at a factory, assembled with rebar, brought into the site, and then poured into the site. For the SY Beam standard cross-sectional shape, a cross-sectional dimensional width of 400mm and depth 600mm determined through structural modeling using the MIDAS GEN program were applied. A total of 6 specimens were made with a member length of 5,000mm, 5 specimens and one RC specimen in the comparison group were manufactured in real-size format using the thickness of the steel plate(0.8, 1.0, 1.2mm) as a variable, and bending experiments were performed. In the bending test, the steel plate deck showed high initial stiffness and maximum strength as it yielded, which showed that it sufficiently contributed to the flexural strength. It is judged that additional analysis and experimental studies for 1.05, 1.1, and 1.15mm are needed to derive the appropriate steel plate thickness and the method for calculating the tensile force contribution of the steel plate to secure the manufacturing, construction and economic feasibility of SY Beam in the future.

Structural Performance Evaluation of Reinforced Concrete Column Reinforced with Aramid Fibers and PET Fibers (아리미드섬유와 PET섬유시트로 보강한 철근콘크리트 기둥의 구조성능평가)

  • Dong-Hwan Kim;Min-Su Jo;Jin-Hyeung Choi;Woo-Rae Cho;Kil-Hee Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.78-85
    • /
    • 2023
  • This study evaluates the performance of reinforced concrete columns using hybrid fiber sheets for structural behavior. The purpose of this method is to improve the load-bearing capacity of the reinforced structure by impregnating a hybrid fiber sheet, which is woven by arranging aramid and glass fibers uniaxially and attached to an aged concrete structure requiring reinforcement with epoxy. In particular, not only the weight reduction of the material obtained by using a fiber lighter than the steel material, but also the low-strength, high-toughness fiber element among the fibers used delays the brittle fracture of the high-strength, low-toughness fiber element. The low-strength, high-toughness fiber element among the fibers used delays the brittle fracture of the high-strength, low-toughness fiber element, resulting in weight reduction compared to steel. The study conducted structural tests on four specimens, with the hybrid reinforcement method and failure mode as main variables. Specimen size and loading conditions were chosen to be comparable with previous studies. The structural performance of the specimen was evaluated using energy dissipation capacity and ductility. Analysis shows that excellent results can be obtained with the hybrid fiber sheet reinforcement.

Growth and Production of Mactra veneriformis (Bivalvia) on the Songdo Tidal Flat, West Coast of Korea (서해 송도 갯벌에서의 동죽(Mactra veneriformis: Bivalvia)의 성장과 생산)

  • 신현출;고철환
    • 한국해양학회지
    • /
    • v.30 no.5
    • /
    • pp.403-412
    • /
    • 1995
  • The present study was performed to determine th growth and production of Mactra veneriformis on the Songdo tidal flat off Inchon. west coast of Korea. Monthly samples were collected from Marc 1989 to September 1990. The size distributions of shell length showed unimodal patterns from March to August 1989. The binodal pattern after September 1989 indicated a recruitment of young clams during this period. The density fluctuated irregularly, but showed a decreasing pattern over time on the whole. The density of the year class 1989 increased markedly after February 1990. The growth in shell length showed three phases during a year, a fast growth phase in spring, a slow growth phase in summer and autumn, and a lag phase in winter. The annual increment in shell length reduced with age. The flesh dry weight showed a peak in late spring just before the spawning period, and another peak in autumn. The length of annuli and the back-calculated flesh dry weight were used to describe the annual growth. The growth in shell length fitted to the von Bertalanffy model and the flesh dry weight to the Gompertz model. The absolute growth rate of the shell length reduced gradually with age. The year class 1985 had the highest L, and the yeat class 1986 the lowest L. The annual growth in weight showed a typical sigmoid curve. The growth rate was maximum at the age of 2 to 3. Year classes of 1984 and 1985 had higher values of W and higher absolute growth rates than those of 1986 and 1987. Maximum absolute growth rates of 1986 and 1987 year classes were recorded at younger ages than 1984 and 1985 year classes. The annual relative growth rates of length and weight decreased exponentially with age. Biomass in flesh dry weight increased till spring and thereafter decreased progressively. Maximum biomass was 134.6g m/SUP -2/ in August 1990. The biomass of 1989 yeat class occupied highest proportion in total biomass. Annual production in flesh dry weight from March 1989 to March 1990 was 67.9 g m/SUP -2/ year/SUP -1/. Cumulative production of 1989 year class was highest among all year classes, and that of year class 1984 was lowest. The production is high in spring and autumn, and very low in summer and winter.

  • PDF

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF