• Title/Summary/Keyword: 연료 소비

Search Result 441, Processing Time 0.025 seconds

A Study on the Influence of Consumer Type on the Choice of Next-Generation Eco-Friendly Vehicle and Consumer Purchase Intention - Comparative Study on Japan and Korea - (소비자 유형이 차세대 친환경자동차선택속성과 소비자 구매의도에 미치는 영향에 관한 연구 - 한국 일본 비교연구 -)

  • Yim, Ki-Heung;Chong, Min-Young
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.133-146
    • /
    • 2017
  • In recent years, the development and market participation of major makers of next-generation eco-green vehicles has been accelerating. Consumer interest has also increased. Consumer characteristics, consumption type, characteristics of next-generation eco-friendly vehicles, and government policies on next eco-green vehicles. The results of this study are as follows. In Korea, there was no significant difference by gender, age, monthly average income, and consumer type. However, there was no significant difference in purchase intention by gender, age, and monthly income, Respectively. In the case of Japan, there was no significant difference by gender, age, monthly income, and consumer type. In Korea, on the other hand, images such as brand, color, and design have positive effects on eco-friendly vehicles. In the case of Japan, image and stability have a positive effect on consumers' purchasing behavior. Therefore, it is important for Japanese consumers to consider not only the image of purchasing an eco-friendly vehicles, but also the safety of the vehicles body, appear. In the case of Korea, the socio-environmental value-seeking type has a significant relationship with the purchasing intention. In the case of socio-environmental value-seeking type, the government's support policy such as carbon dioxide tax, direct support from the national or local governments, gasoline tax, Carbon tax and fuel related tax relief showed positive effects. In the case of Japan, the price-seeking type and the socio-environmental value-seeking type were found to have a significant relationship with the purchasing intention. Both the price-seeking type and the socio-environmental value-seeking type showed that the carbon dioxide tax, Direct support, gasoline tax, gasoline tax, and carbon tax, etc. have positive effects.

Effects of Precombustion Chamber Shape on the Start ability of Small Diesel Engine under the Cold Weather (소형(小型) 디젤엔진의 예연소실(豫燃焼室) 형상(形狀)이 냉시동성(冷始動性)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Moon, Gyeh Song;Kim, Yong Whan;Lee, Seung Kyu
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.9-19
    • /
    • 1982
  • The aim of this study was to improve the startability of the diesel engine at low temperature. The specific objective was to determine the optimum type of precombustion chamber. The eight different types of precombustion chamber and two different types of the cylinder head were designed and tested by $2^7$ factorial experiments with four replications. The lowest starting temperature for first operation, the maximum output, and the specific fuel consumption at full load and overload were checked and analyzed. The results of the study are summarized as follows; 1. The lowest starting temperature was lowered as much as $2.4^{\circ}C$ and the maximum output was increased as much as 0.3 ps with respect to the difference in the relative angle of the main passageway against the piston head from 20 degree to 18 degree. 2. The lowest starting temperature and the maximum out-put were lowered as much as $3.3^{\circ}C$ and 0.3 ps respectively with respect to the difference in the angle of the cylinder head groove from 20 degree to 18 degree. 3. The lowest starting temperature and the maximum out put were lowered as much as $2^{\circ}C$ and 0.2 ps respectively with respect to the difference in the length of the precombustion chamber from 17.5 mm to 15.5mm. 4. There was no significant difference in the startability but the maximum output was increased as much as 0.2 ps with respect to the difference in the diameter of the main passageway from 4.8mm to 4.5mm. 5. The lowest starting temperature was obtained under the condition at 47 degree in the angle of the main passageway and at 18 degree in the angle of the cylinder head groove. The maximum output and the minimum specific fuel consumption was obtained under the condition at 4.5mm in the diameter of the main passageway and at 17.5mm in the length of the precombustion chamber. 6. The angle of the cylinder head groove and the main passageway appeared to the major factors affecting the startability significantly. The interaction between the diameter of the main pass ageway and the length of the precombustion chamber had an significant influence on the maximum output. So it would be recommended to study further on the interaction between two factors mentioned above by expanding their levels. 7. The optimum condition suggested by this study could lower the starting temperature by $6^{\circ}C$ compared to the conventional precombustion chambers.

  • PDF

The Effect of Electrode Spacing and Size on the Performance of Soil Microbial Fuel Cells (SMFC) (전극간 거리와 크기가 토양미생물연료전지의 성능에 미치는 영향)

  • Im, Seong-Won;Lee, Hye-Jeong;Chung, Jae-Woo;Ahn, Yong-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.758-763
    • /
    • 2014
  • Soil microbial fuel cells (SMFC) have gained a great attention as an eco-friendly technology that can simultaneously generate electricity and treat organic pollutants from the contaminated soil. We evaluated the effect of electrode spacing and size on the performance of SMFC treating soil contaminated with organic pollutants. Maximum power density decreased with increase in electrode distance or decrease in electrode size, likely due to higher internal resistance. The maximum voltage and power density decreased from 326 mV and $19.5mW/m^2$ with 4 cm of electrode distance to 222 mV and $5.9mW/m^2$ with 9 cm of electrode distance. In case of electrode size test, the maximum voltage and power density generated was 291 mV, $0.34mW/m^3$ when both of anode and cathode area were $64cm^2$ with 4 cm of electrode distance. The maximum voltage decreased by 19~29% when the anode area decreased to $16cm^2$ while only 3~12% of voltage decreased with cathode area decrease. The maximum power density decreased by 49~68% with decreasing anode size, and by 29~47% with decreasing cathode size. These results showed that the anode area had more significant effects than the cathode area on the power generation of SMFC which has a high internal resistance due to a coexistence of soil and wastewater in the reactor.

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse (온수배관에 의한 온실 내부의 온도변화)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Bae, Seoung-Beom;Kim, Hyeon-Tae;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • This study was performed to obtain a heat saving effect and enhance the efficiency of a greenhouse by using a hot water piping in order to minimize the operating costs of a greenhouse as oil prices continue to rise. This method also reduces the likelihood of accidents caused by snowdrifts in regions with heavy snowfall. In general, the experimental plot was $2.0{\sim}6.0^{\circ}C$ higher than the control plot. When the skylight felt was opened, the minimum temperature was in the range of $3.0{\sim}12.0^{\circ}C$. Therefore, we judged that damage caused by snowdrifts may be prevented partly by active heating. The temperature difference inside of the greenhouse by height was insignificant. The maximum heating load of the greenhouse according to crop was respectively about $37,000kcal{\cdot}h^{-1}$ and $41,700kcal{\cdot}h^{-1}$. During the experiment, the heat value of each designed temperature in the range of the minimum ambient temperature $-11.9{\sim}4.0^{\circ}C$ was about 95,000~322,000 kcal and it was in the range of $6,050{\sim}20,900kcal{\cdot}h^{-1}$. If it is compared with the maximum heating load, it can be shown that about 15~56% of the heating energy can be supplied. The total heat value and the amount of power consumption were 2,629,025 kcal and 677.3 kWh respectively during the experiment. If it is heated with diesel, a fossil fuel, the consumption during the experiment was 291 L and the cost was 331,700won. Total cost of using electric power was about 24,400 won and it is shown that it is about 7.5% of the cost of diesel consumption. Also, if the total amount of power consumption is converted into energy, it is approximately 582,200 kcal and the energy was just about 22% of the total heat value.

Effect of Flywheel Weight on the Vibration of Diesel Engine (플라이휠 중량(重量)이 디젤 기관(機關)의 진동(振動)에 미치는 영향(影響))

  • Myung, Byung Soo;Kim, Sung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.20 no.2
    • /
    • pp.167-180
    • /
    • 1993
  • Most of small size diesel engines are widely used with the same size and weight flywheel in the levels of 6.0kW and 7.5kW. This study was conducted to obtain basic data which affect the engine performance of the power tiller. The flywheel weight was considered as a major factor in this research. Basically, fuel consumption ratio, motoring loss, torque, vibration and mechanical efficiency of the engine were measured and analyzed on four levels of flywheel weight, 32.2, 29.4, 26.2 and $24.2kg_f$, respectively. Results were obtained as follows: 1. The weights of flywheel were $23.7kg_f$ from design program of JSME and $24.5kg_f$ from ASME and SAE design criteria. Therefore, the flywheel weight of $32.2kg_f$ might be reduced about $8kg_f$ in 7.5kW engine. 2. The rated outputs of 6.0kW and 7.5kW engine were actually 7.43kW and 7.85kW, respectively. When flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, outputs were increased from 7.43kW to 7.70kW in 6.0kW engine and from 7.85kW to 8.25kW in 7.5kW engine. 3. When the flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, fuel consumption ratio was decreased from 300.8 to 296.8g/kW-hr in 6.0kW engine and also from 313.6 to 312.8g/kW-hr in 7.5 kW engine, respectively. 4. When the flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, mechanical efficiency of engine was increased from 76.1% to 76.8% in 6.0kW engine and also from 76.7% to 77.0% in 7.5kW engine, respectively. 5. When the flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, vibration was decreased at X-axis and Z-axis in 6.0kW engine, however, slightly increased at Y-axis in 6.0kW engine and at all axes in 7.5kW engine. 6. When the flywheel weight was reduced from $32.2kg_f$ to $24.4kg_f$ motoring loss was decreased from 2.33kW to 1.75kW in 6.0kW engine and also from 2.46kW to 1.84kW in 7.5kW engine.

  • PDF

A Study on the Calculation of GHG Emission for Domestic Railroad Transport based on IPCC Guideline (IPCC 가이드라인을 이용한 국내 철도수송에 따른 온실가스 배출량 산정에 관한 연구)

  • Lee, Jae-Young;Kim, Yong-Ki;Lee, Cheul-Kyu;Rhee, Young-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.408-412
    • /
    • 2012
  • Recently, new climate change mechanism after 2020 year has been accepted with the parties, and so government is pushing ahead the GHG reduction policies to achieve the effective results. Especially, it is essential to enhance the role of railroad in the public traffic system as well as to develop new cars with high energy efficiency for the GHG reduction of transportation sector. Thus, the calculation method of GHG emission of railroad should be established to manage the emission continuously. In this study, the calculation method of GHG emission of railroad was defined with Tier level considering its emission sources to refer to 2006 IPCC guideline for national GHG inventories. Also, the GHG emission of railroad at Tier 1 level was investigated using the activity data related to the amount of diesel and electricity consumption from 2008 to 2010. As a result, total GHG emission in 2010 was about 2,060 thousands ton CO2e, which have 73% of electricity and 27% of diesel. In future, the plans on the GHG reduction of railroad will be accomplished by the analysis of the detailed trends on the basis of the emission management of Tier 3 level under operating patterns. Therefore, it is important to develop the specific GHG emission factors of railroad in advance.

Structural Performance Evaluation of Floating PV Power Generation Structure System (수상 부유식 태양광발전 구조물의 구조적 성능 평가)

  • Choi, Jin Woo;Seo, Su Hong;Joo, Hyung Joong;Yoon, Soon Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1353-1362
    • /
    • 2014
  • In recent years, numerous environmental problems associated with the excessive use of fossil fuel are taking place. For an alternative energy resource, the importance of renewable energy and the demands of facilities to generate renewable energy are continuously rising. To satisfy such demands, a large number of photovoltaic energy generation structures are constructed and planned with large scale. However, because these facility zones are mostly constructed on land, some troubles are occurred such as rising of construction cost due to the cost of land use, environmental devastation, etc. To solve such problems, the floating type photovoltaic energy generation system using FRP members have been developed in Korea. FRP members are recently available in civil engineering applications due to many advantages such as high strength, corrosion resistance, light weight, etc. and they are suitable to fabricate the floating structures because of their material properties. In this study, the analytical and experimental investigations to evaluate the structural performance of floating PV generation structure and SMC FRP vertical member which is used to fabricate the structure were conducted. The static and dynamic performances of floating PV generation structure are evaluated through the FE analysis and the experiment, respectively. Moreover, the structural safety evaluation and buckling analysis of SMC FRP vertical compression member are also conducted by the FE analysis, and the structural behavior of SMC FRP member under compression and pullout is investigated by the experiments. From this study, it was found that the structural system composed of pultruded FRP and SMC FRP members are safe enough to resist externally applied loads.

미래를 선도할 10대 청정에너지 기술

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.451
    • /
    • pp.22-31
    • /
    • 2014
  • 온실가스 다량 배출로 인한 지구온난화 현상은 많은 분야에서의 변화를 요구하고 있다. 특히 온실가스 배출의 주원인으로 꼽히고 있는 발전 등 에너지산업 분야의 경우 그 요구는 매우 거세다. 과거에는 경제성장이라는 측면만 고려하면 됐지만, 지금은 기후변화 대응을 위해 환경을 최우선적으로 고려할 것을 주문하고 있기 때문이다. 문제는 현재 전 세계적으로 약 20%에 이르는 인구가 전기 에너지를 사용하지 못하고 있다는 점이다. 즉 향후 에너지를 사용하고자 하는 신규 소비자는 더욱 늘 것이고, 산업의 발전으로 인한 에너지 소비 역시 큰 폭으로 증가할 수밖에 없다. 문제가 굉장히 어렵지만 해결책도 분명 존재한다. 결론적으로 말해 온실가스 배출을 최소화하면서도 에너지 효율은 높인 기술을 개발하면 되는 것이다. 그리고 이미 세계 각국은 청정에너지 기술개발을 위해 다각도의 노력을 펼치고 있는 상황이다. 그렇다면 세계 각국은 미래 에너지시장을 선도할 청정에너지 기술로 어떤 것을 꼽고 있을까. 이 질문에 대한 대답은 지난 5월 서울에서 개최된 '제5차 클린에너지장관회의(CEM, Clean Energy Ministerial)'에서 제시된 바 있다. CEM은 한국, 미국, 영국, 독일, 중국, 일본 등 세계 에너지의 70%를 사용하는 주요 국가의 관계 장관들이 모여 클린에너지 공급 확대와 에너지효율 향상을 위한 구체적 액션플랜을 논의하는 자리다. 2010년 미국에서 첫 회의가 열렸고 아랍에미리트, 영국, 인도에 이어 한국은 5번째로 CEM을 개최했다. 특히 이번 CEM에서는 회원국들의 의견을 모아 10대 청정에너지 혁신기술을 최초로 선정, 발표했다. CEM은 "향후 10년 간 에너지 시장의 변화를 선도할 유망 기술을 선정한 것으로 IEA 등 국제기구와 주요국 기술 로드맵을 기준으로 해 23개 회원국 회람을 거쳐 최종 확정하게 됐다"고 배경을 설명했다. 이번에 선정된 10대 청정에너지 혁신기술은 ${\triangle}$초고압직류송전 ${\triangle}$에너지저장장치 ${\triangle}$바이오연료 ${\triangle}$마이크로 그리드 ${\triangle}$탄소포집 및 저장 ${\triangle}$초고효율 태양광 발전 ${\triangle}$해상풍력 ${\triangle}$신재생에너지 하이브리드시스템 ${\triangle}$빅데이터 에너지관리시스템 ${\triangle}$지열 시스템이다. 이와 관련해 산업통상자원부 윤상직 장관은 "이번에 선정된 10개의 기술은 최근의 기술적 정책적 추세가 잘 반영된 결과"라고 평가했다. 특히 윤 장관은 "중앙집중형 공급원에서 분산형 전원으로의 변화, 에너지 효율향상의 중요성, ICT와 융 복합 추세 등 우리나라의 상황에서 시사하는 바가 크다"며 "현재 수립하고 있는 '제3차 국가에너지기술 개발계획'에 이러한 기술적 추세를 반영하겠다"는 의사를 표명했다. 향후 10년 간 에너지시장의 변화를 선도할 10대 청정에너지 유망기술을 자세히 소개한다.

  • PDF

Evaluation of Drying Performances by Hydrothermal Reaction of Sewage Sludge and Food wastes (하수슬러지 및 음식물류폐기물의 수열반응에 의한 건조 효율 평가)

  • Shin, Myung-Seop;Lee, Hyung-Don;Jeon, Yong-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.1
    • /
    • pp.47-55
    • /
    • 2017
  • The technology for hydrothermal reaction of organic waste is one of the promising process to improve energy efficiency of biomass waste recycling system since moisture contents of treated biomass could be reduced at 40% or less than by dehydration processes. For these reasons, many parts of the world are interested in hydrothermal reaction of organic waste. In this paper, drying performances were evaluated with and without hydrothermal reaction of organic wastes which are sewage sludge and food wastes. For the hydrothermal reaction, organic wastes were treated at $200^{\circ}C$ for 1hr. Drying time of treated organic waste by hydrothermal reaction was reduced. In case of food waste drying at $100^{\circ}C$, drying time of treated wasted was reduced more 52.9% than non-treated. Hence, drying performances of sewage sludge and food wastes should be improved by hydrothermal reaction. Drying rates of treated wastes were considerably increased at preheat period of drying characteristic curve as followings; at $80^{\circ}C$ sludge as 148%, $100^{\circ}C$ sewage sludge as 151%, $80^{\circ}C$ food waste as 209%, $100^{\circ}C$ food waste as 366%. It means the surface area of treated wastes could be increased with destruction of cell membrane by hydrothermal reaction. However, the designer and operator of drying process should be careful, since enhanced drying rate cause the extension the decreasing drying period.