• Title/Summary/Keyword: 연기제어

Search Result 123, Processing Time 0.026 seconds

A Study on High-precision Autofocus Matching Device for Smoke Detector Based on IR Laser (IR 레이저 기반 연기감지기를 위한 고정밀 자동초점 정합장치에 관한 연구)

  • Kim, Gwan-Hyung;Shin, Dong-Suk;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2759-2764
    • /
    • 2014
  • Smoke detector is commonly used to reduce fire detection time. However, technical problems regarding its inaccuracy of laser beam-receiving point on the surface of the sensor associated with incoming interference are identified when the laser transmitter and receiver are installed at a distance of about 100m. In this paper, we propose the auto focus alignment algorithm with high precision to adjust tilting angle of lasers caused by environmental interference so that solve existing issues using multi-level worm gear set.

Design and Implementation of IR Laser Focus Alignment Algorithms Using CdS (조도센서(CdS)를 활용한 IR레이저 초점정합 알고리즘 설계 및 구현)

  • Lim, Ji-yong;Kim, Gwan-Hyung;Shin, Dong-Suk;Kim, Myeong-Ho;Jeon, Jae-Hwan;Oh, Am-suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.499-500
    • /
    • 2014
  • 화재발생 시 인명 안전을 위하여 초기의 화재감지가 매우 중요한 요인이다. 특히 도로터널, 지하철역사 등 광범위 폐쇄공간에서 연기에 의한 질식사 등 2차 피해의 발생위험이 높다. 이에 최근 광범위 공간에서 적외선 레이저를 활용한 원거리 연기검출 화재탐지기에 대한 연구가 진행되고 있다. 이러한 레이저 기반 원거리 연기검출장치는 이격(100m 이상) 설치되는 레이저 발신기와 수신기의 레이저 포인트가 정확히 정합되어야 한다. 아울러, 레이저 발신기와 수신기 사이의 거리에 비례하여 레이저 초점의 이동거리가 매우 민감하게 변화하므로 이를 정확히 정합하기 위한 고정밀 제어장치가 필요하다. 따라서 본 논문에서는 복수개의 레이저 발신모듈과 복수개의 조도센서(CdS)를 통해 초점의 정합을 자동 추적할 수 있는 알고리즘을 설계, 구현하였다. 이는 초기 레이저 초점의 설정과 이후 외부환경에 따른 초점의 틀어짐을 자동 보정하여 다양한 레이저 인식 장치에 적용될 것으로 사료된다.

  • PDF

A study on the Development of Smoke Detector Sensitivity Test Equipment (휴대용 연기감도시험기 개발에 관한 연구)

  • Kim, Hyeong-Gweon;Kwon, Seong-Pil;Yoon, Hun-Ju;SaKong, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.125-132
    • /
    • 2009
  • In this study we could contribute to the development of a precise checking tool with which the reliability of the automatic fire detection systems was enhanced and the safety of the people was ensured. In the same way as the domestic technical standard, the portable smoke sensitivity tester, which was developed in this work, could be used to check the capability of the smoke detectors installed in the field. Its heater inside was warmed up to $400^{\circ}C$ in 40 seconds and the paper as a smoke source was burned to produce smoke for the test. With the Photoelectric smoke detector it was possible to measure and control the smoke concentration in a range from 0%/m to 25%/m. With the adjustment of rpm of the fan, it was possible to keep a constant wind velocity in a range from 20cm/sec to 40cm/sec.

The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor (스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향)

  • Jeon Heung-Kyun;Choi Young-Sang;Choo Hong-Lok;Jang Jun-Young
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.70-89
    • /
    • 2005
  • Fire scenarios in a space $20.0m\;\times\;4.0m$ floor and 3.0m high were simulated by using computational fluid dynamics program (FDS 4.0.3) to investigate the effect of the combined operation of both sprinkler and vent systems, which are installed for cooling and blocking smoke which propagates beneath the ceiling of a horizontal corridor, on the temperature and smoke density of it. It was shown that the combined operation both sprinkler and vent systems was more effective than each operation for cooling and blocking smoke, the number of operating sprinklers was two because of corner effect of wall, and over-installed sprinklers deteriorated the effect of cooling and blocking smoke. This study showed that the case of two sprinklers and vent flow rate $3.0m^3/s$ in fire scenario was the most effective for cooling and blocking smoke. It was confirmed that the smoke downdrag occurs in operating sprinkler system, and the more smoke droplets produced by increasing fire size, the greater smoke downdrag occurred.

Full-Scale Test of Smoke-Control Performance of a Subway Tunnel (지하철 본선터널 제연성능 실물 실험)

  • Park, Won-Hee;Lee, Duck-Hee;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.94-102
    • /
    • 2011
  • Hot smoke test is done in a subway tunnel. Alcohol trays of 1.0 MW and smoke generators are used for generating hot smoke. The fans equipped with the tunnel are successively run 9 min after smoke generation. It is verified how hot smoke is controlled by fans. Velocity and direction of flow, temperature and smoke density are measured and analyzed for smoke control performance of the tunnel with fans and analyzed from the fire-safety-point of view. Velocity of smoke flow is obtained by using measured velocity and temperature at the ceiling of the tunnel. The time when smoke-control flow is builded up is different for the different positions. Velocity distributions at various positions will be used for the boundaries and the comparison data in numerical simulations for evaluation on smoke-control facilities of subway tunnel.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

A Study on the Prediction of Descending Smoke Time according to the Design Method of Domestic and Foreign Smoke Facilities for the Improvement of Smoke Facilities Standards in Logistics Warehouse (물류창고의 배연설비 기준 개선을 위한 국내·외 배연설비의 설계 방법에 따른 연기하강시간 예측에 관한 연구)

  • Hun, Ye-Rim;Kim, Yun-Seong;Jin, Seung-Hyun;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.141-142
    • /
    • 2022
  • Recently, fires in logistics warehouses in Korea are continuously increasing. In addition, the need for fire safety in logistics warehouses is emerging. So, it is believed that it is necessary to establish standards for vent facilities under effective smoke control for the evacuation safety of residents in logistics warehouses. Therefore, this paper compares the standards related to combustion facilities in Korea, the United States, and Japan, and applies the design method to logistics warehouses of domestic materials to predict smoke drop time and use it as a basic data for improving domestic smoke facilities standards.

  • PDF

A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System (가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • In this study fire control characteristics for inflammable materials of water curtain system are experimentally analyzed. Heat release rate for pinewood and gasoline was calculated using Room Corner Tester (RCT) and fire test apparatus for water curtain system is manufactured. Nozzles (180 degree of injection angle, 8.2 mm of orifice diameter) are installed at the nearby ceiling of place at 5 m distance from fire originate and temperature profile as well as transmission are obtained from the fire experiment of pinewood and gasoline in the water curtain system. Based on the results, parameters of engineering importance for fire control characteristics of water curtain system such as generation of high temperature smoke and thermal phenomena of fluid flow by injection nozzle are identified.