• Title/Summary/Keyword: 연간 성능계수

Search Result 25, Processing Time 0.035 seconds

An Analysis of Energy Savings on the Solar-Absorption Heat Pump Systems for the Residential Use with the consideration of Annual Performance (연간 성능을 고려한 가정용 태양열-흡수식 히트펌프의 에너지 절약효과 분석)

  • Lee, J.H.;Lee, K.S.;Won, S.H.;Lee, M.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.263-275
    • /
    • 1991
  • Studies on the annual performance of three different type of solar-absorption heat pump system (parallel type, series type, and generator type) are carried out by using the computer simulation. These include the calculation of solar energy from the solar collector, and the revision of computer package, developed by Oak Ridge National Laboratory, to predict the annual performance. Finally using weather data and load conditions, the annual performance are obtained. Results show that the annual operating costs of three solar-absorption heat pump systems are almost same values and 44% lower than that of the pure absorption heat pump system. The total annual input energys of solar-absorption heat pump systems are also about 44% lower than that of the pure absorption heat pump. The nominal size of the solar-absorption heat pump systems can be reduced to a value of 55% that of the pure absorption heat pump that would normally be specified under identical conditions.

  • PDF

A Study on Development of Performance Evaluation Model for Life-Cycle Management of River Facilities (하천시설 생애주기관리를 위한 배수통문 성능평가모델 개발)

  • Yoon, Kwang Seok;Kim, Sooyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.420-420
    • /
    • 2018
  • 하천법에서 정의하고 있는 하천시설은 시설은 제방과 수문을 포함하여 20여종에 달한다. 이 중 하천유지 보수 매뉴얼(국토교통부, 2016)에서 정한 유지관리 대상은 총 14종이며, 국가 및 지방하천 정비와 유지관리에 4대강살리기사업 완료 시점인 2012년 이후 연간 약 1.3조원의 예산을 투입하고 있다. 연간 막대한 예산이 투입되어 관리되고 있는 하천관리의 효율성을 제고하기 위해 하천시설에 대한 생애주기관리기법적용 연구가 진행 중이며 이를 위해서는 하천시설의 성능에 대한 정확한 평가가 선행되어야 한다. 본 연구에서는 배수통문에 대한 성능평가모델을 산정하는 방법을 제시하였다. 우선적으로 배수통문의 설치년도와 시설물안전등급을 조사하고 등급별 평균사용연수를 산정하고 시설물 성능예측 기본식의 계수를 산정하여 성능평가모델 산정식을 도출하였다. 배수통문 성능평가모델 산정식과 등급별 평균 사용연수를 비교하여 산정식의 적용성을 검증하였다. 본 연구를 통해 하천시설의 사용연수에 따른 성능을 개략적으로 예측하여 유지관리예산 투입의 우선 순위를 결정하는데 기초자료로 활용이 가능하다고 판단된다.

  • PDF

Economic Evaluation of ATES Heat Pump System (ATES 열펌프 시스템의 경제성 평가)

  • Kim, Namtae;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.199-199
    • /
    • 2011
  • ATES(Aquifer Thermal Energy Storage) 열펌프 시스템은 기존의 다양한 열원 적용 시스템 대비 효율이 우수한 것으로 알려져 유럽과 미국에서 건물 냉난방 시스템으로 적용되고 있다. 특히, ATES 시스템은 기존의 냉난방 시스템 대비 경제성이 우수한 것으로 알려져 있으나 국내에서는 이에 대한 연구 결과는 전무한 실정이다. 본 연구에서는 ATES 열펌프 시스템의 실증 성능 결과를 분석하였으며, LNG 보일러와 에어컨을 사용하는 기존의 냉난방 시스템을 비교시스템으로 ATES 열펌프 시스템의 경제성 평가를 수행하였다. ATES 시스템의 연간 실증 성능 실험결과 ATES 시스템은 외기온도와 무관하게 연중 안정적인 성능을 나타내었다. 경제성 평가시에 생애주기법(Life Cycle Cost)을 적용하여 ATES 열펌프 시스템의 설치 및 운전에 필요한 총 소요비용을 산정하고, 이 결과를 바탕으로 투자회수기간법을 통해 ATES 시스템의 투자회수 기간을 산정하였다. 생애주기법 적용 시에 현재가치법을 사용하였으며, 현재가치법은 수명주기에 발생하는 모든 투자비용과 절감액을 일정한 시점을 기준으로 등가환산하는 방법을 의미한다. 현재가치법에 사용되는 현재가치는 초기비용과 현재가치계수의 곱으로 나타나는데, 여기에서 현재가치계수는 임의의 이자율로 일정기간 동안 정기적인 할부금액이 적립될 때의 현재금액을 구하기 위해 사용하는 계수를 의미한다. 전기와 LNG는 각각 2009년 7월의 (주)한국전력공사와 (주)한국가스공사의 고시요금을 적용하였다. 본 시스템은 실증 설비용량인 20RT를 대상 건물로 가정하였고, 초기투자비는 크게 공사비와 냉난방 설비 구입비로 구성되어 있으며, 기본적인 물가지표는 (사)한국물가정보(KPI)의 고시 데이터를 참조하였다. 각 시스템의 초기투자비는 ATES 시스템이 비교대상 기존 냉난방 시스템 대비 5.7배 높게 나타났다. 일일 8시간 사용기준으로 계절별 전력요금을 고려한 연간운전 비용은 ATES 시스템이 기존 시스템 대비 냉난방 시에 각각 77%와 16%를 나타내어 운전비용이 연간 절감되었고, 난방 운전 시 절감 비율이 냉방시보다 크게 나타났다. 두 시스템에 대한 생애주기비용을 산정하기 위하여 에어컨과 보일러의 기존시스템과 ATES 시스템의 가용연수를 모두 20년으로 설정하였고, 유지보수 비용은 초기투자비용의 2%로 설정하고, 할인율은 은행 예금이자를 기준으로 5%로 설정하였다. 전기와 LNG의 요금 상승률은 (사)한국물가정보를 바탕으로 각각 2%와 8%로 가정하였다. 이러한 조건에서 생애주기법을 이용한 경제성평가는 ATES 시스템의 경우 생애운전비용이 초기투자비용보다 작게 나타났으며, 기존 냉난방 시스템은 생애운전비용이 초기투자비용에 비하여 높게 나타났다. 본 연구 대상 ATES 열펌프 시스템의 실증 성능 데이터와 기존 문헌으로부터 얻은 냉난방 시스템의 성능 결과를 이용하여 생애주기 비용을 적용한 결과 ATES 시스템의 기존 시스템 대비 투자회수 기간은 6.62년으로 나타났다. 특히, 본 연구에서는 ATES 시스템이 국내 최초로 적용됨에 따라 스크린 등의 부품을 다소 고가의 제품으로 시스템에 적용하였으므로 ATES 시스템의 신뢰성과 안정성이 확보되면 초기 투자비 감소가 가능할 것으로 예상되며, 기존 시스템 대비 투자회수 기간은 더욱 감소될 수 있을 것으로 예상된다.

  • PDF

Study on the method to evaluate performance of Light Collector in Light-collecting System (집광채광 설비 입사부의 성능 평가방법에 관한 연구)

  • Yoon, Yongsang;Mun, Sunhye
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.49.1-49.1
    • /
    • 2011
  • 집광채광 설비는 건축물의 조명에너지 절감 및 자연광의 실내 유입을 위해 적용 가능한 태양에너지설비로써 다른 신 재생 에너지 설비와 다르게 연간에너지생산에 대한 정량적 데이터가 아직까지 부재하다. 집광채광 설비의 설치효과를 판단하기 위해서는 집광채광 설비 설치에 따른 연간 에너지생산량 산출이 필요하며, 이를 위해서는 각 구성부분(집광부, 전송부 및 산광부)의 광전송 효율에 대한 데이터가 구축되어야 한다. 본 연구는 집광채광 설비의 효율 분석에 관한 첫 번째 단계로써 외부광속에 대한 집광부 통과 직후의 내부광속의 비율을 예측하였다. 국내에 보급된 집광채광 설비는 대부분 프리즘형과 광덕트형이며, 우선적으로 집광부 입사면의 경사각과 방위각이 다양하여 내부광속 산출방법론이 매우 복잡한 프리즘형을 분석대상으로 삼았다. 전일사량, 외부조도 및 집광부 내부조도가 측정되었으며, 외부광속으로부터 내부광속을 산출하는 공식을 유도하기 위해 천공상태에 따라 전일사량 측정치가 직산분리 되었다. Perez model과 Liu and Jordon에 의해 제시된 계산식과 입사면 및 집광부 면적을 고려하여 수평면 외부조도 측정치로부터 외부광속이 그리고 내부조도로부터 내부광속이 산출되었다. 입사면의 투과율이 동일하다는 전제 하에 천공상태에 따른 태양광 투과 비율을 도출한 결과, 담천공(Kt ${\leq}$ 0.3)에서 0.39, 부분담천공(0.3${\geq}$ 0.78)에서 1.0으로 나타났다. 도출된 투과비율을 외부광속에 적용하여 내부광속을 계산한 결과치와 측정치는 약 ${\pm}9%$ 정도의 차이를 보였다. 연간 기상데이터에 위와 같은 방법론이 적용되면 프리즘형 집광부의 연간 내부광속이 산출될 수 있다. 또한 기존 연구에서 제시된 발광효율 산출식과 일사 파장에 따른 시감도를 고려하면 매 시간별 외부조도도 산출이 가능하다. 일사량 측정치와 외부조도 측정치 사이의 상관관계를 분석한 결과 결정계수 $R^2$이 0.99인데 반해 일사량 측정치와 외부조도 계산치 사이의 상관관계 결정계수는 0.95로 측정치 보다 약간 작은 값을 갖는다. 이렇게 산출된 외부조도는 각 입사면의 면적을 반영하여 외부광속으로 변환되고, 앞서 산출된 천공상태별 투과비율이 적용됨으로써 내부광속이 도출될 수 있다. 이와 같은 집광부에 대한 연구를 바탕으로 향후 전송부와 산광부 효율을 도출하고 궁극적으로 집광채광 설비를 통해 실내에 전달되는 연간 빛에너지를 예측할 수 있을 것이다. 또한 본 연구의 방법론은 다른 형태의 집광채광 설비에도 적용이 가능할 것으로 판단되며, 국내 집광채광 설비의 연간 에너지생산량에 대한 폭 넓은 데이터 구축이 가능할 것으로 기대된다.

  • PDF

Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump (직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Woo, Joung-Son;Baik, Young-Jin;Jang, Jea-Chul;Kim, Ji-Young;Ra, Ho-Sang
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

Annual Performance Evaluation of Direct Expansion Vertical Closed-Loop Ground Source Heat Pump for Residential Application (주거용 직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.114-122
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed -loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

Power performance Testing of Small Wind Turbine Generator System (소형 풍력발전시스템의 출력성능검사)

  • Kim, Hyeon-Ki;Kim, Byeong-Min;Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.123-128
    • /
    • 2011
  • In this study, procedures, a power performance testing system of Wind Turbine System Research Center of Kangwon National University is introduced. Test prodedures and results are presented on a stand-alone vertical-axis 200W wind turbine manufactured by Geum-Poong Energy Inc.. Power performance test is performed according to IEC standard. The test results are compared with the power performance standard. Also, the effects of normalization and disturbed sectors are considered.

  • PDF

The Field Test of Power Performance Measurement for U50 Wind Turbine (U50 풍력발전기 출력성능 실증연구)

  • Hwang, Jin-Su;Jang, Seong-Tae;Kim, Dae-Hyun;Bang, Jo-Hyug;Ryu, Ji-Yune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.372-375
    • /
    • 2007
  • 750kW gearless type wind turbine, named U50, is developed by UNISON in Korea. The newly developed wind turbine should be evaluated the power curve and the estimated annual energy production by following international standard to verify the power performance characteristics. This paper shows the test and evaluation procedure according to IEC 61400-12-1 which specifies a procedure of measuring the power performance characteristics of a single wind turbine and applies to the testing of wind turbines of all types and sized connected to the electrical power network. And this paper also shows the power performance characteristics for U50 wind turbine which is determined in accordance with IEC regulation.

  • PDF

Assessment on the Energy Efficiency Performance by the Fore-body Retrofit of the Coastline (연안선박의 선수부 개조에 의한 에너지 효율 성능 분석)

  • Park, Dong-Woo;Kim, Kyung Sung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.965-971
    • /
    • 2017
  • The primary objective of this study was to assess the energy efficiency performance of an optimized hull form capable of saving energy based on existing vessels. The bow shape of existing vessels was investigated, giving consideration to design draft and speed. Resistance performances were also assessed for existing vessels according to operating conditions. Commercial CFD codes and model test materials were used to assess effective power. An optimized hull form with minimum resistance was selected given real operating conditions. The effective horsepower of existing and optimized vessels was estimated at three speeds. Resistance performance for an optimized vessel showed a 6 % improvement in effective horsepower at design speed (12 knots) compared to existing vessels. Quasi-propulsive efficiency employed experimental data, while energy efficiency performance was analyzed based on operating days, bunker fuel oil C cost, daily fuel oil consumption and specific fuel oil consumption. Energy efficiency performance for an optimized vessel showed a gain of 30 million won per year in reduced costs at design speed (12 knots) compared to existing vessels.