• Title/Summary/Keyword: 역 브레이튼 사이클

Search Result 12, Processing Time 0.021 seconds

역 브레이튼 사이클을 이용한 산업용 가스터빈의 성능 향상에 관한 연구

  • 공창덕;김경두;기자영;최인수;노홍석
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.18-18
    • /
    • 2000
  • 산업용 가스터빈에서 대기로 방출되는 배기열을 효과적으로 이용하기 위한 역 브레이튼 사이클 가스터빈(Reverse Brayton Cycle Gas Turbine) 엔진의 출력과 비연료 소비율 및 열효율을 기본 브레이튼 사이클 엔진, 재열사이클에 역 브레이튼 사이클을 추가한 엔진, 역 브레이튼 사이클에 중간냉각기를 추가한 엔진의 출력, 비연료 소비율 및 열효율을 비교하였다.(중략)

  • PDF

Design of Thermodynamic Cycle and Cryogenic Turbo Expander for 2 kW Class Brayton Refrigerator (2 kW급 브레이튼 냉동기용 열역학 사이클 및 극저온 터보 팽창기 설계)

  • Lee, Jinwoo;Lee, Changhyeong;Yang, Hyeongseok;Kim, Seokho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.299-305
    • /
    • 2016
  • The High Temperature Superconducting power cables (HTS power cables) become increasingly longer to commercialize the HTS power cable system. Accordingly, demands on refrigerators of large cooling capacity per a unit system have been increased. In Korea, it is currently imported from abroad with the high price due to insufficient domestic technologies. In order to commercialize the HTS power cables, it is necessary to develop the refrigerators with large cooling capacity. The Brayton refrigerators are composed of recuperative heat exchangers, compressors and cryogenic turbo expanders. The most directly considering the efficiency of the Brayton refrigerator, it depends on performance of the cryogenic turbo expander. Rotating at high speed in cryogenic temperature, the cryogenic turbo expanders lower temperature by expanding high pressure of a helium or neon gas. In this paper, the reverse Brayton cycle is designed and the cryogenic turbo expander is designed in accordance with the thermodynamic cycle.

Comparison of Dynamic Operation Performance of LNG Reliquefaction Processes based on Reverse Brayton Cycle and Claude Cycle (Reverse Brayton 사이클과 Claude 사이클 기반 LNG 재액화 공정의 동특성 운전성능 비교)

  • Shin, Young-Gy;Seo, Jung-A;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.775-780
    • /
    • 2008
  • A dynamic model to simulate LNG reliquefaction process has been developed. The model was applied to two candidate cycles for LNG reliquefaction process, which are Reverse Brayton and Claude cycles. The simulation was intended to simulate the pilot plant under construction for operation of the two cycles and evaluate their feasibility. According to the simulation results, both satisfy control requirements for safe operation of brazed aluminum plate-fin type heat exchangers. In view of energy consumption, the Reverse Brayton cycle is more efficient than the Claude cycle. The latter has an expansion valve in addition to the common facilities sharing with the Reverse Brayton cycle. The expansion valve is a main cause to the efficiency loss. It generates a significant amount of entropy associated with its throttling and increases circulation flow rates of the refrigerant and power consumption caused by its leaking resulting in lowered pressure ratio. It is concluded that the Reverse Brayton cycle is more efficient and simpler in control and construction than the Claude cycle.

A Study on the BOG Re-liquefaction System based on the Reverse Brayton Refrigeration Cycle for LNG Carriers (역 브레이튼 냉동사이클을 이용한 LNG 운반선의 증발기체 재액화 시스템에 관한 연구)

  • Chin, Young-Wook
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.149-154
    • /
    • 2007
  • The LNG carriers have been propelled by steam turbines and the LNG boil-off(BOG) has been used as fuel or vented. However, as the alternative propulsion systems such as diesel engines are being equipped on the LNG carriers for better fuel efficiency, a need for the LNG BOG re-liquefaction system that liquefies the BOG and sends the liquid BOG back to the LNG cargo has arisen in recent years. This study investigates the design of the BOG re-liquefaction system based on the reverse Brayton refrigeration cycle. The thermodynamic and heat exchanger analysis are carried out and the limitations to the system performance are discussed.

Design of a Cryogenic Turbo Expander Drive Shaft for 300 W Class Brayton Refrigerators (300 W급 브레이튼 냉동기용 극저온 터보 팽창기 구동축 설계)

  • Kim, Manryeol;Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.129-135
    • /
    • 2016
  • There have been many types of development and commercialization efforts for superconducting power applications with the continuous development of High Temperature Superconducting (HTS) conductors. In particular, HTS power cables are going to be commercialized in real power grids. A cryogenic refrigeration system should be used to keep it below 77 K, and its required cooling capacity continuously increases as the unit length of the HTS power cable increases. Among the many kinds of cryogenic refrigerator, a reverse Brayton refrigerator that uses turbo expanders is a promising refrigerator due to its efficiency and reliability. Among the various components in refrigerators, the cryogenic turbo-expander is the most important part for increasing efficiency and assuring reliability. The design of a 300 W class turbo-expander is described in this paper prior to the development of a 10 kW class turbo expander, which is the required capability for the commercialization of a HTS power cable. The impeller shape and rotation speed are determined based on the cycle analysis. The Eigen frequency and harmonic analysis are conducted with gas bearings at cryogenic temperatures to determine the operational stability.

Performance Test and Evaluation of ACM for Fighter's External POD (전투기 외장 포드용 ACM의 성능 시험평가)

  • Paek, Seung-Yun;Seo, Ja-Won;Song, Deok-Hee;Kim, Kyeong-Su;Hong, Jae-Pyo;Park, Sung-Soon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.527-530
    • /
    • 2010
  • A performance test of an air cycle machine with an air to air heat exchanger was performed. The air cycle machine designed for avionics cooling in a fighter's external pod is a small turbo machine operated on the reverse Brayton air cycle driven by captured ram air which is the source of driving energy and it can be used as cooling fluid going through electronics in the pod during the flight. The air to air heat exchanger was also used to avoid moisture for avionics. The performance test have verified that the developed ACM and heat exchanger meet the design requirements.

  • PDF

Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System (초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석)

  • Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.

Performance Test of 2 kW Class Reverse Brayton Refrigeration System (냉동능력 2 kW 급 역브레이튼 극저온 냉각시스템 성능시험)

  • KO, JUNSEOK;LEE, KEUN-TAE;PARK, SEONG-JE;KIM, JONGWOO;CHOO, SANGYOON;HONG, YONG-JU;IN, SEHWAN;PARK, JIHO;KIM, HYOBONG;YEOM, HANKIL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.429-435
    • /
    • 2020
  • This paper describes the experimental study of reverse-Brayton refrigeration system for application to high temperature superconductivity electric devices and LNG re-liquefaction. The reverse-Brayton refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa, cooling capacity of 2 kW at 77 K, and neon as a working fluid. The refrigeration system is developed with multi scroll compressor, turbo expander and plate heat exchanger. From experiments, the performance characteristics of used components is measured and discussed for 77-120 K of operating temperature. The developed refrigeration system shows the cooling capacity of 1.23 kW at 77 K and 1.64 kW at 110 K.