• 제목/요약/키워드: 역브레이튼

검색결과 14건 처리시간 0.019초

BOG 내부 열교환을 이용한 LNG 선박용 Boil-Off Gas 재액화 시스템 (Boil-Off Gas Reliquefaction System for LNG Carriers with BOG-BOG Heat Exchange)

  • 이윤표;신유환;이상훈;김광호
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.444-451
    • /
    • 2009
  • The price increase of natural resources and the worldwide growth of LNG demand led to save the waste of Boil-Off Gas evaporating from cargo tanks of LNG carriers during navigation. As one of the efforts, a BOG reliquefaction system with BOG-to-BOG heat exchanging method was newly devised. This study was also discussed on the process details such as some features and advantages including comparisons with conventional BOG reliquefaction system, non BOG-BOG heat exchange type. The thermodynamic analysis for the system were also performed. Through the cycle simulation, the process efficiency of the BOG reliquefaction system BOG-BOG heat exchange was estimated to be increased up to 21%.

전투기 외장 포드용 ACM의 성능 시험평가 (Performance Test and Evaluation of ACM for Fighter's External POD)

  • 백승윤;서자원;송덕희;김경수;홍재표;박성순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.527-530
    • /
    • 2010
  • 전투기에 장착되는 정보수집용 포드의 냉각 장치인 ACM에 대한 성능 시험평가를 수행하였다. 시험평가 대상인 ACM은 역 브레이튼 공기 사이클로 작동되는 터보기기로서, 항공기의 비행속도에 의한 램 공기를 에너지원으로 사용하여 추가적인 에너지의 공급 없이 냉각 기체를 발생시킨다. 또한 습기에 민감한 전자장비의 냉각에 이용하기 위하여 열교환기를 함께 구성하였다. 성능시험을 통하여 개발 대상 ACM 및 열교환기는 요구 성능을 만족함을 확인하였다.

  • PDF

Reverse Brayton 사이클과 Claude 사이클 기반 LNG 재액화 공정의 동특성 운전성능 비교 (Comparison of Dynamic Operation Performance of LNG Reliquefaction Processes based on Reverse Brayton Cycle and Claude Cycle)

  • 신영기;서정아;이윤표
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.775-780
    • /
    • 2008
  • A dynamic model to simulate LNG reliquefaction process has been developed. The model was applied to two candidate cycles for LNG reliquefaction process, which are Reverse Brayton and Claude cycles. The simulation was intended to simulate the pilot plant under construction for operation of the two cycles and evaluate their feasibility. According to the simulation results, both satisfy control requirements for safe operation of brazed aluminum plate-fin type heat exchangers. In view of energy consumption, the Reverse Brayton cycle is more efficient than the Claude cycle. The latter has an expansion valve in addition to the common facilities sharing with the Reverse Brayton cycle. The expansion valve is a main cause to the efficiency loss. It generates a significant amount of entropy associated with its throttling and increases circulation flow rates of the refrigerant and power consumption caused by its leaking resulting in lowered pressure ratio. It is concluded that the Reverse Brayton cycle is more efficient and simpler in control and construction than the Claude cycle.

36 MTD급 천연가스 BOG 재액화 플랜트 기본설계 (Basic Design of 36 MTD Class Natural Gas BOG Re-Liquefaction System)

  • 고준석;박성제;김기덕;홍용주;고득용;김효봉;염한길
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.99-105
    • /
    • 2013
  • LNG 극저온기계기술 시험인증센터에 구축되는 LNG 선박용 펌프 및 압축기 성능시험에서 발생하는 증발가스는 안전을 위하여 전량 회수가 요구된다. 본 논문에서는 36 MTD 용량의 천연가스 재액화 시스템에 대한 기본 설계 연구를 수행하였다. 대기압, $-60^{\circ}C$, 일반적인 도시가스 조성비, 1,500 kg/hr 유량의 공급 가스를 기본 설계 조건으로 하여 공정 설계가 이루어졌고, 입구 온도 조건 및 가스 조성비에 따른 LNG 생산량 또한 계산하여 다양한 입구 설계 조건에 따른 시스템의 성능 변화를 비교, 분석하였다. 공정 설계 외에도 재액화 시스템의 핵심 기기인 송풍기, 압축기, 극저온 열교환기, 컴팬더의 제작 사양이 도출되었으며, 전력 및 냉각수의 유틸리티 요구조건 또한 기본 설계를 통해 도출되었다.