Synchronous Generator Digital Exciter System PSS Control (동기발전기 디지털 여자 시스템 PSS 제어)

  • 홍현문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.144-148
    • /
    • 2004
  • This thesis also proposes an applied digital exciter control system for a synchronized generator using a digitally PSS controller. Experiment results show that the digital control system manifests excellent control performance compared to analog control systems. It has also been confirmed that it is easy for the modern control theory to implement digital control.

Controller Design of Active Head-eye System with Redundant Degree of Freedom (여자유도를 갖는 능동시각시스템의 제어기 설계)

  • Kim, Do-Yoon;Ryoo, Jung-Rae;Park, Hyum-Keun;Chung, Myung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2711-2713
    • /
    • 2000
  • 능동시각시스템의 가장 큰 장점은 주어진 환경에 대해 능동적으로 반응할 수 있는 자유도가 있어 이를 활용하여 필요한 정보를 쉽게 추출할 수 있다는 점이다. 이를 위해서는 능동시각시스템의 시선을 원하는 위치로 이동시키는 것이 필요한데, 시스템의 여자유도 인해 해가 무수히 많이 존재하게 된다. 본 논문에서는 이러한 여자유도 문제를 기구의 동역학적 특성을 제한 조건으로 하여 최적의 해를 구하고 이를 이용해 각 관절을 제어하는 제어기를 설계하는 방법에 대해 소개한다. 설계된 제어기는 제작과 실험을 통해 고속으로 움직이는 물체를 실시간으로 추적하는 성능을 보였다.

  • PDF

Time Response Characteristics by the exciter types (여자기 형식에 따른 시간 응답 특성 비교)

  • Shin, Man-Su;Lee, Ju-Hyun;Lee, Gi-Seong;Jeong, Tai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2152-2154
    • /
    • 2003
  • 전력계통 및 발전기의 안정 운용을 위해 발전기 제어계의 정밀 제어와 정확한 계통 해석을 위한 발전기 관련 정밀 파라미터 취득 및 관리가 요구되는 상황에서 발전기 현장시험과 발전기 관련 안정도 해석용 데이터 취득이 필요한 실정임. 현장 시험(발전기 제어계 특성시험)을 통해서 취득한 데이터를 가지고 모델링 및 제어정수를 조정하여 전력계통 안정도 해석용 데이터 베이스를 구축하게 되는데, 여자기 형식에 따라서 계단 입력 신호가 주어졌을 때 시간응답 특성이 약간씩 차이가 나게 됨. 그리고 발전기 제어계 특성시험은 발전기 직접 관련 데이터 및 원동기(터빈) 입력신호(주증기 유량신호, 주증기 제어밸브 개도 등)까지 측정하게 되는데, 본 논문에서는 발전기 여자제어에 관련된 부분만을 살펴 보았음.

  • PDF

Power Control Techniques Using Secondary Excitation of Wound Rotor Induction Motor With Flywheel (플라이휠장치를 갖는 유도전동기의 2차 여자를 이용한 계통의 전력보상기법)

  • 김윤호;이경훈;박경수
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.342-347
    • /
    • 2000
  • 최근 산업계에서 급증하는 전력수요와 부하의 다양화는 전원의 안정도에 악영항을 미치고 있다. 이는 전압강하는 역률 저하 유/무효 전력의 변동을 초래하고 타부하에 영향을 미치게 되므로 이를 효과적으로 보상할 수 있는 종합적인 보상 시스템이 필요하다. 본 논문에서는 이러한 전력보상 시스템중의 하나로서 플라이휠을 장착한 권선형 유도기의 2차 여자방식을 제시한다. 본 시스템은 전동기 2차 여자방식을 이용함으로서 기존의 정지형 보상기에 비하여 인버터의 용량을 기존의 것보다 수배 감소시킬 수 있는 장점이 있으며 히스테리시스 전류제어기를 사용하여 직접 전류제어기를 사용하여 직접전류 제어방식을 이용하므로 기존의 시스템과 비교하여 PI제어기의 게인선정의 어려움을 극복하고 제어 알고리즘을 간략화 할 수 있는 특징을 가지고 있다. 또한 전력을 보상하기 위한 에너지 저장요소로 플라이휠의 관성에너지를 사용함으로서 기존의 배터리 방식의 무정전 전원공급장치를 대신하는 효과를 보인다. 설계된 시스템과 제어방식은 시뮬레시션을 통하여 입증하였다.

  • PDF

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

A High Performance Exciter Control System of Synchronous Generator using Direct Instantaneous Voltage Control Method (직접 순시전압 제어기법에 의한 동기발전기의 고성능 여자 제어시스템)

  • Lee, Dong-Hee;Liang, Jianing;Lee, Sang-Hoon;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.68-74
    • /
    • 2007
  • This paper presents a simple, robust excitation control system for synchronous generator using direct instantaneous voltage control(DIVC) method DIVC method can operate as maximum dynamics of power conversion system without any control gains such as PID controller. And the transient overshoot of generator voltage can be suppressed with a simple time constant. The proposed control scheme is verified by the computer simulation and experimental results in prototype generation system.

A Study on Torque Optimization of Planar Redundant Manipulator using A GA-Tuned Fuzzy Logic Controller (유전자 알고리즘으로 조정된 퍼지 로직 제어기를 이용한 평면 여자유도 매니퓰레이터의 토크 최적화에 관한 연구)

  • Yoo, Bong-Soo;Kim, Seong-Gon;Joh, Joong-Seon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.5
    • /
    • pp.642-648
    • /
    • 2008
  • A lot of researches on the redundant manipulators have been focused mainly on the minimization of joint torques. However, it is well-known that the most dynamic control algorithms using local joint torque minimization cause huge torques which can not be implemented by practical motor drivers. A new control algorithm which reduces considerably such a huge-required-torque problem is proposed in this paper. It adapts fuzzy logic and genetic algorithm to the conventional local joint torque minimization algorithm. The proposed algorithm is applied to a 3-DOF redundant planar robot. Simulation results show that the proposed algorithm works well.

Active and Reactive Power Control of Doubly-Fed Induction-type Wind Generator (이중여자 유도형 풍력발전기의 유.무효전력 제어)

  • Jeong, Byoung-Chang;Chung, Yong-Ho;Kim, Sung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.205-207
    • /
    • 2008
  • 본 논문에서는 권선형 유도기를 사용한 이중여자 유도형 풍력발전기용 제어기를 개발하였다. 제어기는 발전기의 회전속도와 발전량, 기리고 계통 전압 등의 조건에 따라서 발전기를 자동으로 제어한다. 발전이 가능한 조건에서는 발전기의 유효전력은 최적값이 되도록 제어된다. 또한, 풍력발전 시스템의 무효전력은 계통 운영자의 요구, 계통 전압, 그리고 발전량 등을 고려하여 무효전력 제어 모드를 스스로 결정하도록 하였다.

  • PDF

Power Control of a Doubly Fed Induction Machine for Wind Energy Generation without Rotational Transducers (풍력발전을 위한 회전변환기가 없는 이중여자 유도기의 전력제어)

  • 김일환
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.72-78
    • /
    • 2000
  • 본 논문에서는 이중여자 유도기를 풍력발전에 적용할 때 회전자위치 센서를 사용하지 않고 발전 출력제어 방법을 제안하였다. 모델기를 풍력발전에 적용하여 운전할 때 고정자는 계통선에 연결되어 있기 때문에 고정자 자속은 일정 값을 가지며 고정자 자속의 동기 각\ulcorner고는 일정한 상수값을 가진다. 또한 회전자 전류 및 고정자 전압과 전류를 이용하여 슬립각을 추정함으로써 속도를 추정할 수 있고 뿐만 아니라 회전자 전류제어에 의해 고정자측의 발전전력을 제어할 수가 있다. 이른 토대로 속도제어 및 발전출력에 대한 결과를 나타내므로써 제안한 알로리즘의 타당성을 입증하였다.

Control of Vibrator using PM Excited Transverse Flux Linear motor (영구자석 여자 횡축형 선형 전동기(TFLM)를 이용한 가진기 제어)

  • Lim Tae Yun;Kang Do Hyun;Kim Jong Moo;Kim Dong Hee
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.33-36
    • /
    • 2001
  • 본 논문은 높은 추력비(전동기 추력/전동기 중량=N/ Kg)를 갖는 영구자석 여자 횡축형 선형 전동기(TFLM)를 가진기 엑츄에이터로 사용하여 부피와 체적을 줄이고 적은 중량이 요구되는 고출력 전동식 가진기 시스템을 유압식을 대체하여 구현하고 가변 변위 및 가변 속도가 가능한 제어 방법을 개발하여 적용하고자 한다.

  • PDF