• Title/Summary/Keyword: 여과량

Search Result 787, Processing Time 0.032 seconds

Determination of the Groundwater Yield of horizontal wells using an artificial neural network model incorporating riverside groundwater level data (배후지 지하수위를 고려한 인공신경망 기반의 수평정별 취수량 결정 기법)

  • Kim, Gyoo-Bum;Oh, Dong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.583-592
    • /
    • 2018
  • Recently, concern has arisen regarding the lowering of groundwater levels in the hinterland caused by the development of high-capacity radial collector wells in riverbank filtration areas. In this study, groundwater levels are estimated using Modflow software in relation to the water volume pumped by the radial collector well in Anseongcheon Stream. Using the water volume data, an artificial neural network (ANN) model is developed to determine the amount of water that can be withdrawn while minimizing the reduction of groundwater level. We estimate that increasing the pumping rate of the horizontal well HW-6, which is drilled parallel to the stream direction, is necessary to minimize the reduction of groundwater levels in wells OW-7 and OB-11. We also note that the number of input data and the classification of training and test data affect the results of the ANN model. This type of approach, which supplements ANN modeling with observed data, should contribute to the future groundwater management of hinterland areas.

Experimental study on the pulse jet cleaning for bag-filter (여과 집진기에서 충격 기류식 역세척 효과에 대한 연구)

  • 박병현;조영민
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.415-416
    • /
    • 2002
  • 급속한 경제발전에 따라 생활 수준이 향상되고 생활양식도 많이 변화되고 있으며 가정이나 생산현장에서 발생하는 폐기물의 발생량은 급속히 증가하고 있다. 해마다 누적되어 가는 폐기물 매립량의 증가로 인하여 기존 폐기물 매립지는 현재 거의 포화 상태에 달해 있다. 이에 따라 우리나라의 폐기물 처리 방법은 기존의 매립위주에서 소각처리로 점차 확대되어 나가고 있는 실정이지만 소각시설 인근 지역의 환경 질 저하에 대한 문제점 및 주민민원 발생 또한 빈번해지고 있는 추세이다. (중략)

  • PDF

Changes in Cardiovascular and Renal Functions by Temperature and Epinephrine in the Freshwater Turtle, Amyda Japonica (수온변화와 Epinephrine에 의한 자라의 심맥관계 및 신장기능의 변화)

  • Kim, Suhn-Hee;Cho, Kyung-Woo;Seul, Kyung-Hwan;Koh, Gou-Young
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.201-210
    • /
    • 1987
  • 수온변화에 따른 심맥관계 및 신장기능의 변화와 생체실험을 통한 온도에 의한 adrenoceptor의 변형을 알아보기 위해, 무마취 자라에서 $18^{\circ}C$에서 $25^{\circ}C$로 수온을 증가시 나타나는 혈압, 심박동수 및 신장기능의 변화를 관찰하고, epinephrine 1 ug/kg과 10 ug/kg을 상이한 온도에 노출된 자라의 정맥내 투여하여 나타나는 효과를 비교하였다. 1) $18^{\circ}C$에서 $25^{\circ}C$로 수온을 증가시킴에 따라 심박동수는 현저히 증가하여 일정하게 유지되었으나, 혈압 및 혈장 renin 활성도는 변화하지 않았다. 온도증가에 의해 뇨량, 사구체여과율 및 전해질 배설량의 현저한 증가를 보였으나 90분부터는 서서히 감소하기 시작하였다. 2) 수온 $18^{\circ}C$에 노출된 자라에서 epinephrine은 dose-dependent한 양상으로 혈압 및 심박동수를 증가시켰으며, 다량의 epinephrine 투여시 작용시간은 현저히 연장되어 있었다. $25^{\circ}C$에 노출된 자라에서는 epinephrine에 의한 혈압상승 효과 및 심박동수 증가는 나타났으나, dose dependency나 작용시간의 차이는 발견할 수 없었다. 3) 동량의 epinephrine에 의한 혈압 및 심박동수의 증가효과는 $18^{\circ}C$$25^{\circ}C$에 노출된 자라에서 유의한 차이를 발견할 수 없었으나, $18^{\circ}C$에 노출된 자라에서 epinephrine의 작용시간 및 반감기가 현저히 연장되어 있었다. 4) Epinephrine 투여에 의해 뇨량, 사구체여과율 및 전해질 배설량의 증가를 관찰하였으며, 이는 dose-dependent 양상이었다. 그러나, 신장효과의 유의한 차이는 상이한 온도에 노출된 두 군에서 발견할 수 없었다. 이상의 결과로, 온도증가에 의한 이뇨 및 sodium 배설효과는 혈관이완에 의한 사구체여과율의 증가에 기인한 것으로 사료되며, 상이한 온도에 노출된 자라에서 epinephrine 효과의 차이를 발견할 수 없었던 것은 본 실험에서 가한 좁은 범위의 온도의 변화 내에서는 adrenoceptor의 변형이 나타나지 않을 것이라고 추론하였다. 그러나 저온에서의 epinephrine의 작용시간의 연장은 아마도 epinephrine의 파괴 효소의 활성도의 감소인 것으로 사료된다.

  • PDF

Physicochemical Effect on Permeate Flux in a Hybrid Ozone-Ceramic Ultrafiltration Membrane Treating Natural Organic Matter (자연유기물을 처리하는 혼합 오존-세라믹 한외여과 시스템에서 물리화학적 특성이 투과플럭스에 미치는 영향)

  • Kim, Jeong-Hwan
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.354-361
    • /
    • 2008
  • Effects of operational conditions and solution chemistry on permeate flux in a hybrid ozone-ceramic ultra-filtration (UF) membrane system treating natural organic matter (NOM) were investigated. Results showed that the extent of permeate flux decline was higher at higher cross-flow velocity and ozone dosage, but it was higher at lower transmembrane pressure (TMP). The mechanism of fouling mitigation was found to be more dependent upon reaction between ozone and natural organic matter at/near catalytic membrane surface than scouring effect due to ozone gas bubbles. Addition of calcium into model NOM solution at high pH led to significant decline in permeate flux while the calcium effect on permeate flux decline was less pronounced at lower pH. After permeate flux decline during the early stage of filtration, the flux started recovering and approached fully to the initial value of it due to degradation of NOM by catalytic ozonation at ceramic membrane surface in the hybrid ozone-ceramic membrane system.

Study on Performance Comparison in Carbon Nanotube Embedded Electrospun Membranes for Particulate Matter Removal (탄소나노튜브가 첨가된 전기방사 멤브레인의 미세입자 제거 성능 비교에 관한 연구)

  • Gu, Minkyung;kim, Dongwan;Han, Sangil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.56-60
    • /
    • 2018
  • There have been a lot of study to improve the performance of membrane filters as the removal of particulate matter has been of great interest due to the negative effects. Among the membrane fabrication techniques, the electrospinning technique is the most promising because it can produce uniform fibers ranging from nano to micrometer size. The electrospun membranes will greatly improve the filtration performance due to the high ratio of surface area to volume and the high porosity. In the present study, polystyrene (PS) and cellulose acetate (CA) polymers were used to produce the membranes with carbon nanotube (CNT), showing the filtration performances were improved with the optimal amounts of CNT.

Hybrid artificial recharge for securing safe water resources (안전한 수자원 확보를 위한 Hybrid 인공함양 기법의 적용)

  • Bang, Woo-Hyuck;Yeom, Hyun;Maeng, Sung Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.286-286
    • /
    • 2020
  • 인공함양은 대수층함양관리 중 하나의 기법이며 하수처리장 방류수의 영향을 직·간접적으로 받은 물을 지하대수층에 함양하여 수질의 향상을 기대할 수 있다. 그러나 방류수의 영향으로 인해 다수의 미량유해물질들이 대수층으로 유입됨에 따라 함양 후 회수할 때 이들의 검출이 빈번해졌다. 이에 따라 이 미량유해물질의 제거를 위해 인공함양의 후속 공정으로 나노막 여과를 고려하여 인공함양과 나노막 공정을 통하여 미량유해물질의 거동을 파악하고자 하였다. 본 연구에서는 인공함양 지하저수지 모사 컬럼을 설계하여 실험하였다. 서울특별시 탄천 하류에서 샘플링한 물을 원수로 사용하였으며 인공함양에 앞서 염소, 과망간산염, 오존의 3종류 산화 전처리를 통하여 그 영향을 확인하고자 하였다. 함양기간은 2.5일이었으며 함양 후 나노막 장치를 통하여 최종 유출수를 획득하였다. 인공함양 결과 용존유기물은 45%~63% 수준에서 제거가 되어 인공함양시 용존유기물의 제거가 가능함을 확인하였다. 산화 전처리에 따른 동화가능유기탄소의 증가로 인하여 생분해가 주요 기작인 인공함양 처리를 통하여 동화가능유기탄소의 제거율이 유기용존탄소의 제거율에 직접적으로 영향을 주었음을 알 수 있었다. 미량유해물질로 알려진 과불화화합물의 경우 산화 전처리에 따른 제거는 관찰되지 않았으며 잔류의약물질의 경우 대상 물질의 물리·화학적 특성에 따라 산화시 제거가 가능함을 확인하였다. Iopromide와 같은 조영제의 경우 오존 산화를 통하여 98% 이상 제거되어 산화를 통한 제거가 가능함을 확인하였다. 인공함양시 과불화화합물은 분자량이 큰 PFNA, PFDA, PFOS 등이 제거되었으며 그 제거율은 각각 최대 >99%까지 도달하였다. 분자량이 작은 과불화화합물의 경우 인공함양을 통과하는 경향을 보였다. 잔류의약물질의 경우 생분해가 용이한 물질은 제거가 됨을 확인하였으며 carbamazepine 등 제거가 안 되는 물질은 제거율이 18% 미만으로 확인하였다. 나노막 여과 결과 과불화화합물이 최대 >99%까지 제거됨을 확인하였으며 미량유해물질의 경우에도 대부분의 물질이 제거됨을 확인하였다.

  • PDF

오.폐수 배출시설 방류수의 재이용 가능성 실태조사

  • 민경우;최형일;백계진;정원삼;이대행;김난희;서광엽
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.05a
    • /
    • pp.346-349
    • /
    • 2004
  • 광주시 관내 폐수배출시설 방류수 6지점과 대형 건축물 오수 처리시설 방류수 4지점 및 중수 처리 재이용수, 건물 옹벽 지하수 2지점의 수질을 분석하여 중수로써 재이용 가능 여부를 조사한 결과 폐수 배출시설 방류수의 경우 조립금속제품 제조시설, 축전지제조시설 및 타이어제조시설이 대체적으로 중수도의 수질기준을 만족하고 있어 현재의 방류수를 그대로 중수로 이용 가능하리라 판단된다. 오수 처리시설 방류수의 경우 4지점 모두 유기물질은 물론 색도, 탁도 등 대부분의 항목이 중수도 수질기준을 초과하여 현재의 방류수 자체를 중수로 사용하기는 불가능 할 것으로 판단되며, 이들 방류수를 중수로 재이용하고자 한다면 모래 여과조나 활성탄 여과조, 소독시설 등 중수 처리시설을 설치하여야 할 것으로 판단된다. 오수처리시설 방류수를 중수 처리하여 재이용 하고 있는 중수의 경우 대부분 중수도의 수질기준을 만족하였으나, 색도와 탁도, 대장균군의 경우 일부 상당히 불안정한 수질을 보였으나 현재 화장실 세정수로 이용하고 있는데 색도 외에는 별다른 문제가 없는 것으로 나타났고, 대형빌딩 옹벽에서 흘러나오는 지하수의 경우 일반세균과 질산성 질소를 제외하고는 모두 먹는물 수질기준에 적합한 것으로 나타나 현재의 지하수를 그대로 청소용수나 화장실 세정수 등의 중수로 재활용해도 충분하다고 판단되며, 활성탄 여과조와 소독 시설 등의 추가시설을 갖춘다면 먹는 물로도 사용이 가능하리라 보며, 수량적인 측면에서도 1일 발생량이 100~400톤 이상이므로 충분히 경제성이 있을 것으로 판단된다.

  • PDF

Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation (금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2004
  • Total resistance of membrane in a micro-filtration system using a metal membrane was mainly attributed to the permeate resistance of cake layer($R_c$), which was formed by deposited particles from the physico-chemical interactions of solids on membrane surface. Intermittent back ozonation was highly effective than the air backwashing for fouling reduction. As far the operational effect, under same ozone injection, the increase of gas flow-rate was more favorable than the increase of injection time far the recovery of permeation flux. As the filtration time was longer, the effect of flux recovery by intermittent back-ozonation decreased. Therefore, it is preferable to operate membrane cleaning before the foulant is consolidated on membrane surface.

Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis (역삼투법 해수담수화 전처리 여과공정의 최적조건)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.