• Title/Summary/Keyword: 엠프

Search Result 15, Processing Time 0.019 seconds

Optimal Design of Flow Measurement System Using Turbine Flowmeter (터빈유량계를 이용한 유량 측정 시스템의 최적 설계)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The turbine flowmeter is selected for high precision and reproducibility at the time of flow rate measurement but causes various uncertainty factors of measurement in the difference between the standard environmental condition at calibration and the environmental condition at the site. Also, a reliable interpolation method is required for use in sections other than calibrated measurement values. Therefore, in this paper, in order to improve the reliability of the flow rate measurement, we designed and manufactured a device that accurately measures the output signal of the turbine flowmeter, interpolates the value of the calibrated result value, and corrects the temperature change in real time We confirmed the reliability of the measurement at the site to carry out the performance verification.

Driving Characteristic of The Thin Type Ultrasonic Motor using Microcontroller (Microcontroller를 이용한 박형 초음파모터의 구동특성)

  • Jeong, Seong-Su;Jun, Ho-Ik;Chong, Hyon-Ho;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.201-201
    • /
    • 2008
  • 박형초음파모터의 구조는 그림 1(a) 와 같이 크로스형태의 앓은 스테이터에 윗면과 아랫면에 각각 8 개의 압전세라믹이 부착된 형태이다. 압전세라믹의 분극방향은 로터와 접촉하는 스테이터의 A, B, C, D 네 개의 타점에서 순차적인 타원변위가 생성되도록 결정된다. 유한요소해석프로그램인 ATILA 5.2.4를 사용하여 최적설계를 한 결과 폭 3[mm], 길이 18[mm], 두께 1.8[mm], Brass 재질, Mid surface clamp 조건에서 입력전압 18[Vrms] 일 때 0.3[${\mu}m$]의 변위를 보였다. 최적설계된 모델을 제작하였고, 정확한 실험결과를 얻기 위해서 푸쉬풀게이지, x-y스테이지, rpm 메타, 토크게이지를 이용하여 실험테이블을 구성하였다. 그림 1(b) 는 마이크로컨트롤러를 이용한 구동 드라이버를 보여준다. 한 주기에서 1/4분주의 순차적인 네 개의 구형파를 생성하고, 이를 push-pull회로를 동하여 90도의 위상차가 나는 정현파를 생성하여 초음파 모터의 구동전원으로 사용한다. 엔코더와 AD 컨버터를 이용하여 정속도 운전을 위한 피드백 제어가 된다. 제안된 구동드라이버를 이용하여 측정한 결과, 구동 주파수 88.6[kHz], 입력전압 [40Vrms], preload 0.2 [N]에서 130 [rmp] 의 속도와 25 [gfcm] 의 토크특성을 보였다. 압력전압을 증가시킬수록 속도는 선형적인 증가를 보였고, 토크는 이와 반대로 감소하는 특성을 보였다. 피드백 제어회로가 없는 경우에는 preload 변화에 따른 극심한 속도 변화를 보였고, 피드백 제어를 하였을 경우에는 0.2~0.4[N]의 범위에서 정속도 운전이 가능함을 확인하였다. 기존의 주파수발생기와 파워 엠프를 이용한 구동장비와의 특성비교에서도 큰 차이를 보이지 않았으며, 장시간의 운전에도 안정적인 구동이 가능함을 확인하였다.

  • PDF

On an Adaptation of Announcement Sound Level in White Noise Environment (백색소음 환경에서 음성안내레벨 적응에 관한 연구)

  • Yun, Jong-Jin;Bae, Myung-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.112-118
    • /
    • 2012
  • In daily life, there are many information broadcasting by using voice information systems. If surrounding noises are mixed with the information signals, the clarity of the signal become down graded too much to understand. Surrounding noises are not uniformed, but very irregular signals always changing. Therefore, it is very hard to control the output signals along with the irregular signals. This paper suggests a method to change the level of the voice information adapting to the surround noise in the white noise environment. The surround noise level is measured by subtracting the stored output voice signal from the voice signal degraded by the noise. The noise is used to estimation of SNR. And, the method to change the output level of voice signal adapting to the noise level. The suggested adaptive voice information system has the advantage to improve listeners' speech perception and to use amplifier's energy effectively.

Analysis of statistical characteristics of bistatic reverberation in the east sea (동해 해역에서 양상태 잔향음 통계적 특징 분석)

  • Yeom, Su-Hyeon;Yoon, Seunghyun;Yang, Haesang;Seong, Woojae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.435-445
    • /
    • 2022
  • In this study, the reverberation of a bistatic sonar operated in southeastern coast in the East Sea in July 2020 was analyzed. The reverberation sensor data were collected through an LFM sound source towed by a research vessel and a horizontal line array receiver 1 km to 5 km away from it. The reverberation sensor data was analyzed by various methods including geo-plot after signal processing. Through this, it was confirmed that the angle reflected from the sound source through the scatterer to the receiver has a dominant influence on the distribution of the reverberation sound, and the probability distribution characteristics of bistatic sonar reverberation varies for each beam. In addition, parametric factors of K distribution and Rayleigh distribution were estimated from the sample through moment method estimation. Using the Kolmogorov-Smirnov test at the confidence level of 0.05, the distribution probability of the data was analyzed. As a result, it could be observed that the reverberation follows a Rayleigh probability distribution, and it could be estimated that this was the effect of a low reverberation to noise ratio.

Detection of Tracheal Sounds using PVDF Film and Algorithm Establishment for Sleep Apnea Determination (PVDF 필름을 이용한 기관음 검출 및 수면무호흡 판정 알고리즘 수립)

  • Jae-Joong Im;Xiong Li;Soo-Min Chae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.119-129
    • /
    • 2023
  • Sleep apnea causes various secondary disease such as hypertension, stroke, myocardial infarction, depression and cognitive impairment. Early detection and continuous management of sleep apnea are urgently needed since it causes cardio-cerebrovascular diseases. In this study, wearable device for monitoring respiration during sleep using PVDF film was developed to detect vibration through trachea caused by breathing, which determines normal breathing and sleep apnea. Variables such as respiration rate and apnea were extracted based on the detected breathing sound data, and a noise reduction algorithm was established to minimize the effect even when there is a noise signal. In addition, it was confirmed that irregular breathing patterns can be analyzed by establishing a moving threshold algorithm. The results show that the accuracy of the respiratory rate from the developed device was 98.7% comparing with the polysomnogrphy result. Accuracy of detection for sleep apnea event was 92.6% and that of the sleep apnea duration was 94.0%. The results of this study will be of great help to the management of sleep disorders and confirmation of treatment by commercialization of wearable devices that can monitor sleep information easily and accurately at home during daily life and confirm the progress of treatment.