An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses (공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1523-1528
    • /
    • 2008
  • In this study, the ventilation system of connection passage and elevator hall of underground parking lot in apartment houses is investigated to extract the data for the installation and the application by the experimentation. In case of the elevator hall, actual air exchange rate is predicted fivefold higher than air exchange rate by infiltration and exfiltration. Ventilation system is installed good by supply air and return air. As the next best thing, it is installed by supply air because of IAQ control. The temperature of connection passage and elevator hall uniformly with $7{\sim}8^{\circ}C$, is maintained even if the operating condition of ventilation system is different. Therefore, the installation of the preheater, which is installed at the inlet of ventilation system for the cold draft in winter, is not essential in southern area of Korea.

Condensation Reduction Study of an Apartment Underground Elevator Hall with respect to Dehumidifier Locations (제습기 설치 위치에 따른 공동주택 지하 엘리베이터홀의 결로 저감 연구)

  • Park, Jong-Jun;Kim, Young-Il;Kim, Jong-Yeob;Kim, Gil Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.169-174
    • /
    • 2014
  • Computational fluid dynamics simulation of an apartment underground elevator hall has been carried out to study the effect of dehumidifier locations on condensation problem. In Case 1, horizontal position of humidifier is studied. It is installed at entrance, center or the inside of the elevator hall. In Case 2, installation height is studied, one at 0 m and the other at 1.6 m above the floor. In Case 3, exposed and embedded dehumidifiers are compared for performance. The study shows that the entrance, top and exposed locations are more effective in reducing condensation.

특정 실험실 조건에서의 사무실용 낮은 칸막이의 소음감쇠성능 측정방법 KS제정을 위한 ISO 규격내용 분석

  • Yang, Kwan-Seop;Jeong, Seong-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.21-24
    • /
    • 2006
  • 대부분의 사무용 건물은 코아 부분(엘리베이터 홀, 화장실, 계단 등)을 제외하고는 Open 되어 있으며, 필요에 따라 부서간에는 천장 면까지 도달하는 경량벽체를 설치하여 독립된 공간을 구획하고, 부서내부에서는 직원들간의 커뮤니케이션은 용이하게 하는 대신에 최소한의 독립성을 제공하기 위해 낮은 칸막이 등을 설치하고 있다. 그러나 사무실에 사용하는 칸막이 벽체 중 천장 면까지 도달하는 칸막이에 대해서는 KS F 2808(건물 부재의 공기전달음 차단성능 실험실 측정방법)의 측정방법을 이용하여 차음성능을 확인할 수 있으나 낮은 칸막이에 대해서는 소음저감 성능을 측정할 수 있는 측정 방법에 관한 규격이 없다. 따라서 기존에 있는 모든 KS 규격들은 국제표준규격인 ISO와의 부합화가 이루어졌거나 이루어지고 있기 때문에 이러한 정부의 방침에 따라 본 낮은 칸막이에 대한 소음감쇠량 측정규격 또한 ISO규격(ISO 10053(음향- 실험실 조건에서의 사무실 스크린의 소음저감성능 측정방법))을 받아들이기 위해 ISO규격 내용을 검토하였다. 향후 이 규격이 그대로 우리나라 규격으로 제정될 때 나탈 수 있는 문제점을 최소화하기 위해 국내에 있는 반 무향실에서 낮은 칸막이의 실제 소음저감 성능을 실시할 계획이다.

  • PDF

Earthquake Simulation Tests on a 1:5 Scale 10-Story R.C. Residential Building Model (1:5 축소 10층 내력벽식 R.C. 공동주택의 지진모의실험)

  • Lee, Han-Seon;Hwang, Seong-Jun;Lee, Kyung-Bo;Kang, Chang-Bum;Lee, Sang-Ho;Oh, Sang-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.67-80
    • /
    • 2011
  • This paper presents the results of shaking table tests on a 1:5 scale 10-story R.C. wall-type residential building model. The following conclusions are drawn based on the test results. (1) The model responded linear elastically under the excitations simulating an earthquake with a return period of 50 years, and showed a nonlinear response under the excitations simulating the design earthquake of Korea. (2) The model showed a significant strength drop under the maximum considered earthquake, with a return period of 2400 years. (3) The major portion of the resistance to lateral inertia forces came from the walls used for the elevator and stair case. (4) Finally, the damage and failure modes appear to be due to the flexural behavior of walls and slabs. A significant deterioration of stiffness and an elongation of the fundamental periods were observed under increased earthquake excitations.

A Study on Development of Remote Crane Wire Rope Flaws Detection Systems (원격 크레인 와이어 로프 결함 탐지 시스템 개발에 관한 연구)

  • Min, Jeong-Tak;Lee, Jin-Woo;Lee, Kwon-Soon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.97-102
    • /
    • 2003
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, the wire rope of crane is important component to container transfer. If it happens wire rope failures during the operation, it may lead to safety accident, economic loss by productivity decline and so on. To solve this problem, we developed remote wire rope fault detecting system, and this system is consisted of 3 parts that portable fault detecting part, signal processing part and remote monitoring part. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data. It is verified that the detecting system by de-noising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension fo wire ropes exchange period and could competitive power. Also, this system is possible to apply in several field such as elevator, lift and so on.