• Title/Summary/Keyword: 엑스선 민감도

Search Result 7, Processing Time 0.023 seconds

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

CdTe기반의 엑스선 검출기의 표면 구조에 따른 박막의 전기적 특성평가

  • Kim, Dae-Guk;Sin, Jeong-Uk;Lee, Yeong-Gyu;Lee, Ji-Yun;No, Seong-Jin;Park, Seong-Gwang;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.432-432
    • /
    • 2013
  • 현대에 이르러 직접방식 엑스선 검출기에서는 기존의 a-Se을 주로 이용하였지만, 고전압 인가에 따른 회로 손상과 짧은 수명, 그리고 누설전류에 따른 안전의 문제 등으로 낮은 에너지 밴드갭과 높은 흡수효율, 비저항 등에 의거한 다양한 대체 물질에 대한 연구가 활발하게 이루어져가고 있다. 본 논문에서는 직접방식 엑스선 검출물질로 전기이동도와 흡수효율이 뛰어나고, 밴드갭이 낮아 태양전지분야 뿐만 아니라 최근 엑스선 검출물질로 각광받고 있는 CdTe를 선정하였다. 연구의 목적은 PVD (Physical Vapor Deposition)방식의 CdTe 검출 물질의 제작과정에서 CdTe가 기화되어 하부전극 기판에 증착될 시, 하부전극 기판 온도에 따른 CdTe의 박막형성과 전기적 측정을 실시하여 그에 따른 최적의 증착조건을 선정하는 것이다. 하부전극 기판으로는 Au/glass를 사용하였으며 증착 시, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$로 나누어 특성을 평가하였다. 시료는 파우더형태의 다결정CdTe를 120 g를 사용하여 증착완료 시, 약 $100{\mu}m$의 박막두께를 구현하였다. PVD증착의 조건으로는 Mo재질의 보트를 사용하였으며, 증착 시 진공도는 $5{\times}10^{-6}$ Torr, 보트온도는 약 $350^{\circ}C$ 소요시간은 5시간이었다. 증착이 완료된 CdTe의 표면구조와 전기적 특성평가를 위해 SEM촬영을 실시하였고, 전기적 특성 평가를 위해 CdTe표면에 Au를 PVD방식으로 증착하였다. 실험 결과 SEM촬영을 이용한 표면특성에서는 하부전극 기판의 온도가 높아질수록 표면 결정입자가 증가하는 것을 확인할 수 있었으며, 전기적 특성에서도 하부전극 기판의 온도가 증가할수록 RQA-5 조건의 70 kVp, 100 mA, 0.03 sec 엑스선에 대한 우수한 민감도와 암전류 값을 확인하였다. 이러한 결과는 증착과정에서 온도에 따른 다결정 CdTe의 표면결정 크기 증가는 동일한 면적에서 표면결정 수의 감소를 뜻한다. 이는 결정간의 경계에서 트랩 되어지는 전자가 감소하고, 전자의 이동도 또한 높은 효율을 나타냄을 확인할 수 있었다. 따라서 본 연구를 통하여 CdTe기반의 직접방식 엑스선 검출기 제작과정에서 증착 시 하부전극기판 온도가 증가할수록 결정의 크기가 증가하여 최적의 전기적 특성을 나타냄을 검증할 수 있었다.

  • PDF

Study on the effect of DSSC(Dye Sensitizer Solar Cell) Material on the electrical properties of Mercuric Iodide (염료감응형태양열 물질이 요오드화수은의 전기적 특성에 미치는 영향에 관한 연구)

  • Cho, Gyu-Seok;Park, Ji-koon;Heo, Seung-Wook;Song, Yong-keun;Han, Moo-Jae;Kim, Kum-Bae;Choi, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.525-529
    • /
    • 2017
  • As a photoconductive material with a high X-ray sensitivity, many researches about mercury iodide has been carried out to substitute for amorphous selenium. However, it has many limitations in commercialization because of the high leakage current. In this study, we fabricated $HgI_2$ unit-cells with mixed silicon oxide($SiO_2$) and titanium oxide($TiO_2$) to reduce a high leakage current and we evaluated an electrical properties of the fabricated unit-cells. As a result, we confirmed that both mixtures were effective in reduing the leakage current of the $HgI_2$ and x-ray sensitivity were significantly increased in fabricated $HgI_2-TiO_2$ unit-cell.

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.

Characteristics of Velocity and Electrical Resistivity in Gassy Sediments Results of Mudbelt Sediments in the Southeastern Inner Shelf of Korea (가스함유퇴적물에서의 음파전달속도 및 전기비저항 특성: 한국남동해역 이토대 퇴적물의 분석결과)

  • Kim, Dae-Choul;Park, Soo-Chul;Seo, Young-Kyo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.4
    • /
    • pp.249-258
    • /
    • 2001
  • Compressional wave velocity and electrical resistivity of muddy sediments in the southeastern inner shelf of Korea were studied using nine piston core samples. The acoustic and physical properties were measured with 10 cm depth interval. Sediment structures were examined by x-radiographs of the cored sediments. Subbottom profiles were obtained by a high-resolution acoustic subbottom profiler. Acoustic turbid layers are clearly seen on the profiles, and x-radiographs of the sediments showed degassying structures formed by gas escaping. On the basis of x-radiographic images, velocities, electrical resistivities and physical properties, the sediments are divided into gassy and non-gassy sediments. The presence of gas and degassying structures result in a marked variation in velocity and electrical resistivity. It can be concluded that velocity and electrical resistivity arep arameter to recognize gassy sediment. The velocity is important parameter to indicate gassy sediment.

  • PDF

Clinical Analysis of Primary Mediastinal Tumors (원발성 종격동 종양의 임상적 고찰)

  • 변정욱;조창욱
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.55-60
    • /
    • 1997
  • We reviewed 40 cases of primary mediastinal tumors which were operated on at Seoul Paik Hospital from September, 1987 to December, 1995. Of these, 18 were male and 22 were female. The patient ranged in age from 4 years to 68 years with a mean age of 34.1 years. The most common symptoms included chest pain(12.5%), cough(12.5%), dyspnea(7.5%). and palpable neck mass(7.5%), and symptoms were absent at the time of diagnosis in 37.5% of cases. Chest roentgenography and computed tomography(CT) were performed in all patients, and magnetic resonance imaging(MRI) in 5 patients, and transthoracic needle aspiration (TTNA) performed In 22 patients. The sensitivity of TTNA was 72.7%(16 of 22 patients). The lesion was located 60% in the anterosuperior mediastinum, 35% in the posterior mediastinum, and 5% in the middle mediastinum. The primary tumors included thymic neoplasms(11 cases), germ cell tumors(7 cases), neurogenic tumors(10 cases) and a miscellaneous group. The malignant tumors(12.5%) were invasive thymoma(3 cases), spindle cell sarcoma(1 case), and non-Hodgkin's Iymphoma(1 case). A complete excision was done in all 35 benign tumors and 3 malignant tumors. There was no operative mortality, and postoperative complications occurred in 3 cases.

  • PDF

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.