• Title/Summary/Keyword: 엑스선영상

Search Result 124, Processing Time 0.022 seconds

A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021 (보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.667-673
    • /
    • 2021
  • As we enter the era of the 4th industrial revolution, it is judged that the scope of work of radiologists will be further expanded according to the innovation and advancement of radiation medical technology development. In this study, the current status of medical equipment and radiology technicians was identified, and basic data were provided for the plan for nurturing talents in the field of radiation medical technology in the era of the 4th industrial revolution, as well as career and employment counseling. Data from the second quarter of 2020 and the second quarter of 2021 were analyzed using health and medical big data. As a result of comparing the status of medical equipment by type in 2021 compared to 2020, C-Arm X-ray examination equipment increased by 5.83% to 6,638 units, followed by MRI examination equipment 1,811 units 5.29%, and angiography equipment 725 units 5.22% , general X-ray examination equipment 21,557 units increased 3.99%, CT examination equipment 2,136 units 3.03%, and breast examination equipment 3,425 units increased 3.00%. As a result of a comparison of the total number of radiologists in 2021 compared to 2020, the number was 29,038, an increase of 2.73%. As a result of comparing the status of radiographers by region, the increase was highest in the Gyeonggi region with 5.96%, followed by the Gangwon region with a 5.66% increase and the Chungnam region with a 3.81% increase. In a situation where the number of medical equipment and radiologist manpower is increasing, universities are developing specialized knowledge and practical competency through subject development related to the understanding and utilization of customized artificial intelligence and big data that can be applied in the medical radiation technology field in the era of the 4th industrial revolution. It is necessary to nurture qualified radiographers, and at the level of the association, it is thought that active policies are needed to create new jobs and improve employment.

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

A Suggested New Clinical Classification for Pediatric Intussusception (소아 장중첩증의 새로운 임상적 분류의 제안)

  • Park, Moon Ho;Shon, Su Min;Choe, Byung Kyu;Kim, Yeo Hyang;Lee, Hee Jung;Choi, Won Joung;Kim, Ae Suk;Hwang, Jin-Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 2006
  • Purpose: We proposed a new classification of pediatric intussusception based on clinical and radiologic findings. Methods: Data from 88 consecutive patients with intussusception were reviewed. We retrospectively analyzed six factors; patient age, sites of intussusception, symptoms, therapeutic methods, existence of enlarged mesenteric lymph nodes, and ultrasonographic (US) findings from clinical records. Results: 1) There was one neonatal case (1.1%), the others (98.9%) were infants and children. 2) These 87 infant and child cases consisted of 14 cases (16.1%) of small bowel intussusception (SBI) and 73 cases (83.9%) of ileo-colic intussusception (ICI). Of the 14 SBI cases, 12 cases were symptomatic and 2 cases were asymptomatic. The symptomatic group comprised 8 transient cases (66.7%), 3 operative cases (25.0%), and 1 enema-reduction case (8.3%). Two asymptomatic cases were incidentally captured by computed tomography. Of the 73 ICI cases, 19 cases (26.0%) required operation, and 54 (74.0%) enema-reduction. 3) When transient SBI cases were compared with operated SBI cases, enema-reduced and operated ICI cases, the age ($38.0{\pm}22.9$ months) of transient SBI cases were significantly higher than those of the others (p=0.003). Mean mass size ($20.8{\pm}2.7mm$) in transient SBI was significantly smaller than in the others (p=0.0001). 4) No correlation was found between the existence of enlarged mesenteric lymph nodes and therapeutic method or concomitant illness. 5) Most of the target types observed by US were in transient SBI cases, the remainder were in the enema-reduced ICI cases. In terms of the doughnuts type, all 8 cases (34.8%) with an external hypoechoic rim thickness of >8.9mm were treated surgically. Conclusion: Pediatric intussusception may be classified based on clinical and radiologic findings, which are likely to indicate appropriate therapies.

  • PDF