• Title/Summary/Keyword: 에어컨 실외기

Search Result 38, Processing Time 0.021 seconds

Environmental Noise Assessment of Outdoor Air-conditioner Fans by Using Ray Tracing Method (레이추적법에 의한 에어컨 실외기의 환경소음 예측에 관한 연구)

  • Choi, Jin-Kwen;Chang, Seo-Il;Lee, Jin-Kyo;Lee, Soo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1444-1449
    • /
    • 2000
  • This environmental influence of the noise produced by a number of air-conditioner out-door units in a multi-unit housing is predicted and evaluated. The method based on Ray tracing theory and mirror image source theory is utilized. Each ventilation window in a machine room is considered as a sound source which contributes to the overall noise level of the surrounding environment. The adopted method has been found a very efficient tool to assess the environmental noise impact.

  • PDF

The prediction of sound transmission from air-conditioner outdoor-units in multi-unit housings (공동주택 에어컨 실외기의 투과소음 예측 및 저감방안에 관한 연구)

  • Choi, Jin-Kwen;Chang, Seo-Il;Lee, Jin-Kyo;Kang, Jeong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.996-1001
    • /
    • 2000
  • The sound transmission from the machine room where air-conditioner outdoor unit is located into the adjacent room is predicted and evaluated. The software package for statistical energy analysis(SEA) is utilized to determine the transmission losses of multi-layerd panels. To determine the noise level in the machine room, ray tracing method is adopted. The various sound transmission paths have been effectively identified and evaluated by the SEA tool.

  • PDF

Flow Noise in the Outdoor Unit of an Air-conditioner (에어컨 실외기에서의 유동소음)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

Sensorless Control Algorithm of a PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han Sol;Cho, Kwan Yuhl;Kim, Hag Wone;Cha, Youn Cheul
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.72-73
    • /
    • 2017
  • 자동차 라디에이터용 팬과 에어컨 실외기 팬의 경우 영구자석동기 전동기는 자연 상태에서 외부 바람에 의해 임의의 방향과 임의의 속도로 회전할 수 있다. 이런 응용분야에서 회전자 위치검출 센서가 부착되어 있는 경우에는 회전방향 및 속도를 비교적 간단하게 제어할 수 있다. 그러나 회전자 위치검출 센서를 사용하지 않는 센서리스 제어의 경우 외부부하에 의해 회전자가 회전중일 때는 회전자의 위치정보가 없기 때문에 추가적인 알고리즘이 필요하다. 본 논문에서는 외부부하에 의해 회전자가 임의의 방향 및 임의의 속도로 회전하고 있는 경우 원하는 회전방향으로 원하는 속도로 제어하기 위한 센서리스 제어 알고리즘을 제안한다. 회전자가 역방향 및 정방향 저속으로 회전중인 경우와 정방향 고속으로 회전중인 경우에 대해 회전자를 정방향의 주어진 속도로 제어하기 위한 회전자 위치검출 및 센서리스 제어 알고리즘을 제안하고 실험으로 검증한다.

  • PDF

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

The Vibration Suppression using Reactive Power Compensator for Speed Control of Parallel Connected Dual Fan Motors fed by a Single Inverter (단일 인버터 기반 에어컨용 실외기 팬 모터 병렬운전에서의 무효전력보상기를 이용한 맥동저감 기법)

  • Yun, Chul;Kwon, Woo-Hyen;Cho, Nae-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2008-2013
    • /
    • 2016
  • This paper proposes analysis and suppression method for reactive power vibration of the slave motor caused by back-EMF mismatch between the master and the slave motor and stator resistance during middle-low speed operation. The master and slave motors are parallel connected dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motors) fed by a single inverter. To suppress vibration of reactive power, RPC(Reactive Power Compensator) proposed in this paper analyzes flux-axis current vibration of the slave motor that occurs in middle-low speed operation using a mathematical model of the fan motor. And RPC adds vibration components detected from flux-axis current of the slave motor to flux-axis current of the master motor. The results of experiment conducted verify the efficacy of the proposed method.

Numerical investigation into cavitation flow noise of hydrofoil using quadrupole-corrected Ffowcs Williams and Hawkings equation (사중극자 보정 Ffowcs Williams and Hawkings 방정식을 이용한 수중 익형 공동 유동소음에 대한 수치적 고찰)

  • Ku, Garam;Ryu, Seo-Yoon;Cheong, Cheolung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.263-270
    • /
    • 2018
  • In most industry fields concerning external flow noise problems, the hybrid computational aeroacoustic techniques based on the FW-H (Ffowcs Williams and Hawkings) equation are widely used for its numerical efficiency. However, when the surface integral form of FW-H equation is used without volume quadrupole sources, it is known to generate significant non-physical noise in a certain case. Especially, in the case of a flow in which the tip vortex cavitation is formed in the distant downstream direction such as flow driven by an underwater propeller, the accuracy in noise prediction becomes poor unless it is not properly modelled. Therefore, in this study, the nonphysical acoustic waves caused by the surface integral form of FW-H equation is reduced by adding the quadrupole correction term. First, to verify the accuracy of the in-house code of FW-H equation, the noise by an axial fan used in the outdoor unit of air conditioner was calculated and compared with the results of ANSYS Fluent. In order to verify the effects of the quadrupole correction term, the noise prediction for isentropic vortex convection is performed and it is confirmed that the error is reduced by the quadrupole correction term. Finally, the noise prediction is performed for the flow field generated by the Clark-Y hydrofoil in underwater. It is confirmed that the error caused by the cavitation passing through the integral surface can be reduced by the quadrupole correction term.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.