• Title/Summary/Keyword: 에어커튼

Search Result 30, Processing Time 0.029 seconds

A Study of Evacuation in Elderly Care Facilities Fire (요양시설 화재 시 피난에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.602-607
    • /
    • 2017
  • The development of science and technology has increased the average life expectancy and resulted in a significant increase in the elderly population. Due to the preponderance of the nuclear family in modern society and the weakening of the spirit of filial piety and respect for the elderly caused by the influence of Western civilization, elderly people are usually not living with their family, but have become dependent on elderly care facilities and, consequently, the number of elderly care facilities has increased significantly. On May 28, 2014, a fire occurred in the elderly care facilities in Jangseong, South Jeolla Province, and despite the rapid extinction of the fire by firefighters, 21 of the 28 casualties died due to smoke inhalation. This study was conducted for the purpose of providing measures to prevent smoke from entering into the rooms from which elderly people have difficulty evacuating in the case of fire. The use of the air curtain method to prevent smoke inflow was proposed and an experiment was conducted in which smoke was generated with a smoke generator. As a result of the experiment, it was confirmed that more than 90% of the smoke inflow was blocked if the door was closed in the room where the air curtain was installed.

Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain (에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

An Experimental Study on the Characteristics of Train-Wind in Underground Shopping Center Connected to Subway Station (지하도 상가와 지하 역사 연계구에서 열차풍 발생 특성에 관한 실험적 연구)

  • Hwang, In-Ju;Lee, Hong-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.82-87
    • /
    • 2005
  • The characteristics of train-wind in the underground shopping center(UGSC) connected to subway station is investigated by field measurement for the case of train movement such as arrival and departure, etc. Also air curtain installed at the pass way between underground shopping center and subway station were considered as the parameter in order to analysis the effect on indoor air quality and thermal condition. The measurement data such as velocity, relative humidity, wind-pressure were plotted as quantity variation with time scale. The train-wind affected wind velocity, air pressure and relative humidity at the connecting area of underground shopping center and subway station, and the variation was about 4.5 m/s, 8%, 40 Pa. Also the result showed that the air curtain is not proper to reduce influence of train-wind

  • PDF

Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table (조리대에 급기구를 가진 주방 레인지후드의 배기 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.

Optimal Conditions of Aerosol Flow Generation for High-density and Uniform Fog Screen (고밀도 균일 안개스크린을 위한 에어로졸 유동의 최적 생성조건)

  • Shin, Dongsoo;Song, Wooseok;Kim, Jinwon;Kim, Woojin;Koo, Jaye
    • Journal of ILASS-Korea
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2017
  • The fog screen is a device projecting the media to the aerosol flow field. As major parameters to generate dense and steady fog screen, shear stress, optical blockage ratio and SMD were obtained result through experiment. The micro droplet was generated by the piezo oscillation element, and the aerosol flow mixed with an air flow was sprayed into the vertical direction from the top of the fog screen through the 280 mm slot. For produce a dense, uniform fog screen, the shear effect, optical blockage ratio and SMD between aerosol and air curtain were measured. The minimum and maximum shear stress conditions were selected and it was confirmed that the optical transmission deviation of the aerosol flow field was small when the aerosol and air curtain flow rates were changed. When the aerosol and air curtain flow power were 18 V (1.51 m/s) and 24 V (2.55 m/s), respectively, under the condition of the minimum shear stress and laminar flow, the optical blockage ratios with the spray length were small, and it produced a most stable and high density uniform fog screen by injecting a constant of $10{\mu}m$ or less.

Characteristics of Hericium erinaceus fruit body genesis in winter (동절기 노루궁뎅이버섯 자실체 발생 특성)

  • Moon, Ji-Won;Lee, Chan-Jung;Cheong, Jong-Chun;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.14 no.2
    • /
    • pp.39-43
    • /
    • 2016
  • In this study, we observed differences in the fruit body genesis in with seasonal changes. The mushrooms generated different spines even when under same environmental conditions in equivalent growth chambers during different seasons. The growth chamber conditions were set at $18^{\circ}$, 1000 ppm CO and 95% humidity for uniform primordium formation. Following this, the humidity was reduced to 85% during growth and development. The characteristics of the fruit body were measured: yield (weight), length (size), hardness, and chromaticity. Each measure was relatively compared owing standard data for. We investigated the environmental factors to assess the cause of variation in fruit body. Change in temperature and humidity were especially focused on, apart from climate that can affect mushroom growth. It was observed that temperature and humidity both influence fruit body growth. Not the absolute value of the elevation, there was a change of climate which the temperature is lowered and lowered the humidity can be assumed that the changes in the environmental conditions inside the growth chamber the mushroom growth.

The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel (지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin;Jeong, Sang-Hyeon;Kim, Yong-Min;Kim, Jong-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

Scaled model tests for improvement and applicability of the transverse smoke control system on tunnels (횡류식 제·배연 시스템의 개선 및 적용성 분석을 위한 모형실험 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Kim, Jae-Hyun;Lee, Seong-Won;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.563-574
    • /
    • 2020
  • Currently, road tunnels and railroad tunnels are building smoke control systems to emit toxic gases and smoke from fires. Among the various smoke control systems, the transverse smoke control system has the disadvantage that air supply or exhaust is performed on only half of the cross-section, rather than air supply or exhaust on the entire cross-section of the tunnel as air is supplied or exhausted by partitioning the wind path. Therefore, this study analyzed the effect of exhaustion through numerical analysis and scaled model tests on the zoning smoke control system, which improved the limitations of the transverse smoke control system. As a result of the scaled model test, the transverse ventilation system exhibited a 25.6% smoke control rate based on the state where no smoke was controled, and zoning smoke control system showed a smoke control rate of 40.8%. In addition, as a result of numerical analysis, it was found that transverse ventilation system did not control fire smoke spreading from the tunnel and continued to spread. On the other hand, zoning smoke control system was found to be smoke controled within a certain section due to the air curtain effect and the flue gas effect.

An Automatic Operating System for Manless Multipurpose in Greenhouse (시설원예의 생력화를 위한 다목적 자동작업장치 개발)

  • 민병로;김웅;이범선;이대원
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.143-148
    • /
    • 2004
  • The automatic operating system was designed and built to work manless multipurpose in greenhouse. The system proved to be a reliable system for performing multipurpose functions. Its development involved the integration of moving part, height control part, watering part, ventilation part and inhalation part. The moving part was able to be moved it on the rail installed in greenhouse, the height control part controled it up and down by height of the crops, the watering part sprinkled a agricultural medicines on the crops and the ventilation and the inhalation part ventilated and inhaled different thing and vermin which were attached on crops. Based on the results of this study the following conclusions were made: The moving velocity was changed 0.047 - 0.027 m/s by the dial transfer. The velocity within 50 cm from center of the entrance was 0.2 m/s. The watering volume of spray increased as the pressure of spray was high. The difference of spray pressure between 10 kg/$\textrm{cm}^2$ and 15 kg/$\textrm{cm}^2$ was 60 ml, but that of spray pressure between 15 kg/$\textrm{cm}^2$ and 20 kg/$\textrm{cm}^2$ was 20 ml. The average speed of a current of inhalation was 3.64 m/s and the inhalation flux of inhalation was measured 0.044 ㎥/s by using glues seed and styrofoam.

Seasonal occurrence of mushroom fly infestation and analysis of the effects of preemptive pest control technology: A case study in button mushroom farms in Buyeo County (부여지역 양송이농가 버섯파리 발생소장 및 사전방제기술 적용효과)

  • Hye-Sung Park;Seong-Yeon Jo;Tai Moon Ha
    • Journal of Mushroom
    • /
    • v.21 no.4
    • /
    • pp.266-269
    • /
    • 2023
  • This study aimed to address the increasing demand for technologies preventing mushroom fly damage. By monitoring the annual occurrence patterns of pests over several years and accumulating data, we conducted an analysis to evaluate the efficacy of preventive measures applied before the surge in mushroom fly infestation, typically observed in May. For preemptive control, physical measures involved installing air curtains at cultivation facility entrances and placing sticky traps and insect traps around entry points to block external entry and reduce internal insect density. Additionally, we applied an organic agricultural material, Dalmatian chrysanthemum extract, weekly alongside chemical control measures. To assess the reduction in mushroom fly populations, yellow sticky traps (15×25 cm) were placed at three locations within the mushroom cultivation facility, and the occurrence patterns before and after implementing preventive measures were compared. Compared to conventional practices, the application of preventive techniques resulted in a significant reduction, with a 60% decrease from 15 levels of mushroom flies/m2 to 6 levels of mushroom flies/m2 in May and a 40% decrease from 10 levels of mushroom flies/m2 to 6 levels of mushroom flies/m2 in June. While achieving over 50% efficacy during the peak mushroom fly season with preventive measures, we identified complementary actions such as blocking external sources (gaps in cultivation facility doors) and maintaining cleanliness around cultivation facilities (proper disposal of spent substrate) for further improvement. Comprehensive analysis and safety studies, including correlation analysis with contaminants and pathogens, are recommended to ensure the widespread adoption of mushroom fly preventive techniques for safe and stable mushroom production in the agricultural sector.