• Title/Summary/Keyword: 에어레이션

Search Result 11, Processing Time 0.023 seconds

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

해수에서 넙치 Paralichthys olivaceus 및 조피볼락 Sebastes schlegeli에 포르말린 처리시 포름알데히드 잔여 효과

  • Jung, S.H.;Kim, J.W.;Jeon, I.G.;Lee, Y.H.
    • Korean Aquaculture
    • /
    • v.19 no.1
    • /
    • pp.34-42
    • /
    • 2007
  • 양식 넙치 및 조피볼락을 이용하여 1시간 동안 포르말린(37% 포름알데히드) 100 mg/l, 300 mg/l 및 500 mg/l의 농도에서 약욕 처리한 후 근육 내에서의 포름알데히드 잔류 농도를 측정하였다. 또한 포르말린 농도 25 mg/l, 50 mg/l, 100 mg/l, 150 mg/l 및 200 mg/l의 에어레이션된 해수와 에어레이션이 공급되지 않은 해수에서의 포름알데히드의 손실율을 측정하였다. 1시간 500 mg/l의 포르말린으로 취급된 어류 근육의 포름알데히드 농도는 약욕(0 h 투여 중지) 후 즉시 분석된 대조구 조직의 포름알데히드 농도보다 유의적으로 높게 나타났다(p<0.05). 그러나 대조구 조직내 포름알데히드 농도는 포르말린에 노출 후 24, 48 및 72시간 지난 후 샘플된 어류조직에서의 농도와 유의적인 차이가 없었다(p>0.05). 25-200 mg/l의 포르말린이 포함된 해수의 포름알데히드는 $8{\sim}19$일 이내에 측정 가능한 아주 낮은 농도($0.05\;{\mu}g/ml$)로 되어지나, 그것의 분해는 에어레이션을 함으로서 $6{\sim}10$일 이내로 빨라졌다. 따라서 본 연구에서 밝혀진 것들은 어류양식산업에 있어서 포르말린의 적정 투여 중지 기간과의 결정에 필요한 자료를 제공한다고 생각된다.

  • PDF

Effects of Oxygen Transfer Rate of a Polystyrene Foam Bead Media in a Packed Column Aerator (Packed Column 에어레이터에서 매질로 이용한 발포스티로폼 입자의 산소 전달 효과)

  • 박정환;김유희;조재윤
    • Journal of Aquaculture
    • /
    • v.13 no.3
    • /
    • pp.267-275
    • /
    • 2000
  • To evaluate the characteristics and efficiency of oxygen transfer rate of a polystyrene foam bead as media in a packed column aerator was tested. This media has more surface area and cheaper than other ordinary plastic media. The polystyrene foam media was a sphere-shaped bead with 2.5 mm in diameter and specific surface area was 1,350 $m^2$/$m^3$. Oxygen transfer rate and standard aeration efficiency were tested under different hydraulic loading rates, depths of the media and temperatures. Experiment 1 was performed using a small packed column aerator with 10 cm in diameter and 1 m in length. The aerator filled with 0, 4.5, 9.0 and 18.0 cm of the media was tested under hydraulic loading rates of 2.0, 4.0 and 5.6 $m^3$/$m^2$/min at temperatures of 20, 25 and 3$0^{\circ}C$, respectively. In this experiment, standard oxygen transfer rate (SOTR) increased with the hydraulic loading rate and depth of the media increased. The maximum SOTR was reached at 5.6 $m^3$/$m^2$/min of hydraulic loading rate with 9 cm in depth of the media. However, standard aeration efficiency (SAE) decreased with the hydraulic loading rate increased because electricity consumed by pump increased as hydraulic loading rate increased. The highest SAE was reached at hydraulic loading rate of 2.0 $m^3$/$m^2$/min with 9.0 cm in depth of the media. Therefore, the highest SOTR and SAE were achieved at 9.0 cm in depth of the media regardless of the hydraulic loading rate. The maximum SAE was about 1.8 kg $O_2$/kW-hr with the hydraulic loading .ate of $m^3$/$m^2$/min at temperature of 20 $^{\circ}C$.Experiment 2 was performed using a larger aerator, 20 cm in diameter with 2 m in height. The aerator filled with 0, 9, 18, 27 and 36 cm of the media was operated under hydraulic loading rate of 2.0, 4.0 and 5.6 $m^3$/$m^2$/min at temperature of 27 $^{\circ}C$. The SAE reached to the highest efficiency (1.9 kg $O_2$/kW-hr) at 2.0 $m^3$/$m^2$/min of hydraulic loading rate and 36 cm in depth of the media. According to the above results, the polystyrene foam bead as a media in a packed column aerator was effective to increase oxygen transfer rate.

  • PDF

Spawning Periodicity and Behavior of Amphiprion melanopus and Development of Mass Hatching System for Clownfishes (Cinnamon Clownfish Amphiprion melanopus의 산란 주기, 산란 행동 및 Clownfish류의 부화장치 개발)

  • Noh, Gyeong-Eon;Rho, Sum;Shin, Sang-Ok;Chang, Young-Jin
    • Development and Reproduction
    • /
    • v.15 no.2
    • /
    • pp.133-141
    • /
    • 2011
  • The marine ornamental industry has become a multi-billion dollar industry these days. As developing, however, this industry has been criticized for the indiscriminate captures and the destruction of the surrounding environment. To circumvent these problems, it is suggested to breed the organisms artificially. While clownfishes Amphiprion sp. and Premnas sp. are the most famous ornamental organisms in the trade, few studies are yet available on the culture and commercial production of these fishes. These studies were performed to investigate the spawning periodicity, behavior and the habits during egg incubation, and to provide the information on the mass hatching system. The spawning periodicity and frequency were different in 4 pairs under the constant condition, temperature, salinity and photoperiod. On the contrary, the male's behaviors for egg incubation are almost same in the all. The egg-fanning activity of the male increased as the developing eggs reaching to the hatching day. Based on the above results, we designed a new artificial hatching system, the rotating type (RT), and compared it with the aeration type (AT) and spray type (ST) that were previously described. RT showed higher hatching rate of 87.3% than AT (74.4%) and ST (60.5%). Also, there were no significant differences in the hatching rate regardless of the number (2, 3, 5) of hatching plates. We suggest RT may accommodate various number of hatching plates and constitute a better hatching system for clownfishes.

The Waveform and Spectrum analysis of Tursiops truncatus (Bottlenose Dolphin) Sonar Signals on the Show at the Aquarium (쇼 학습시 병코돌고래 명음의 주파수 스펙트럼 분석)

  • 윤분도;신형일;이장욱;황두진;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • The waveform and spectrum analysis of Tursiops truncatus(bottlenose dolphin) sonar signals were carried out on the basis of data collected during the dolphin show at the aquarium of Cheju Pacificland from October 1998 to February 1999. When greeting to audience, the pulse width, peak frequency and spectrum level from the five dolphins'sonar signals were 3.0ms, 4.54kHz and 125.6dB, respectively. At the time of warm-up just before the show, their figures were 5.0㎳, 5.24kHz and 127.0dB, respectively. During the performance of dolphins, with singing, peak frequency ranged 3.28∼5.78kHz and spectrum level ranged 137.0∼142.0dB. With playing ring, pulse width, peak frequency and spectrum level were 7.0㎳, 2.54kHz and 135.9dB, and when playing the ball, the values were 9.0㎳, 2.78kHz and 135.2dB, respectively. The values determined from the five dolphins during jump-up out of water were : pulse width 2.0㎳, peak frequency 4.50kHz and spectrum level 126.8dB. When they responded to trainer's instructions, the values were 2.25㎳, 248kHz and 148.7dB, respectively, and greeting to audience, the peak frequency and spectrum level were 5.84kHz and 122.5dB. During swimming under water, peak frequency and spectrum level were determined to be 10.10kHz and 126.8dB. It was found that there exited close consistencies in pulse width, frequency distribution and spectrum level between whistle sounds and dolphin's sonar signals. Accordingly, the dolphins can be easily trained by using whistle sound based on the results obtained from the waveform and spectrum of the dolphin's sonar signals.

  • PDF

The Simulation for the Organization of Fishing Vessel Control System in Fishing Ground (어장에 있어서의 어선관제시스템 구축을 위한 모의실험)

  • 배문기;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.175-185
    • /
    • 2000
  • This paper described on a basic study to organize fishing vessel control system in order to control efficiently fishing vessel in Korean offshore. It was digitalized ARPA image on the fishing processing of a fleet of purse seiner in conducting fishing operation at Cheju offshore in Korea as a digital camera and then simulated by used VTMS. Futhermore, it was investigated on the application of FVTMS which can control efficiently fishing vessels in fishing ground. The results obtained were as follows ; (1) It was taken 16 minutes and 35 minutes to casting and hauling net in fishing processing respectively. The length of rope pulled by scout boat was 200m, tactical diameter in casting net was 340.8m, turning speed was 6kts as well. (2) The processing of casting and hauling net was moved to SW, NE as results of simulation when the current direction and speed set into NE, 2kts and SW, 2kts respectively. Such as these results suggest that can predict to control the fishing vessel previously with information of fishing ground, fishery and ship's maneuvering, etc. (3) The control range of VTMS radar used in simulation was about 16 miles. Although converting from a radar of the control vessel to another one, it was continuously acquired for the vector and the target data. The optimum control position could be determined by measuring and analyzing to distance and direction between the control vessel and the fleet of fishing vessel. (4) The FVTMS(fishing vessel traffic management services) model was suggested that fishing vessels received fishing conditions and safety navigation information can operate safely and efficiently.

  • PDF