• Title/Summary/Keyword: 에너지 측정

Search Result 5,205, Processing Time 0.033 seconds

Validation of Net Radiation Measured from Fluxtower Based on Eddy Covariance Method: Case Study in Seolmacheon and Cheongmicheon Watersheds (에디공분산 방법 기반의 플럭스 타워 순 복사에너지 검증: 설마천, 청미천 유역)

  • Byun, Kyuhyun;Shin, Jiyae;Lee, Yeon-Kil;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • The necessity of clear understanding of water and energy cycles has been attracted recently due to the climate change. The micrometeorological flux tower networks play a role of cornerstone of the hydrological and ecological analyses. Although the eddy covariance techniques used for flux tower have been proven to be applicable for estimation of latent heat flux, the raw data are often underestimated and needs to be corrected. Among several methods, the Bowen ratio is recognized as the most useful method in which the net radiation and other flux data (Ground heat flux, Sensible heat flux) are used and needed to be validated. In this study, in order to validate the net radiation from flux tower in Seolmacheon and Cheongmicheon watersheds, we compare it with two version of calculated net radiation: (1) FAO 56 Daily net radiation proposed by Allen et al. (1998). (2) Instantaneous net radiation proposed by Bastiaanssen (1995). The results showed that the net radiation from the flux data had similar tendency with those calculated based on physical theory. In addition, after it was applied to Bowen ratio method, the corrected latent heat flux was considerably improved with making the energy balance much more closed.

A Measurement of Proton Beam Energy using Carbon Target for Medical Cyclotron (탄소 표적물을 사용한 의료용 싸이클로트론의 양성자 에너지 측정)

  • Chai, Jong-Seo;Ha, Jang-Ho;Kim, Yu-Seok;Lee, Dong-Hun;Lee, Min-Yong;Hong, Seong-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.350-354
    • /
    • 1995
  • 한국 원자력 연구소 부설 원자력병원에 설치된 AVF 싸이클로트론을 이용하여 요즈음 핵의학에 널리 사용되는 PET 용 싸이클로트론의 에너지를 검정 할 수 있고 양성자 과잉 핵종인 싸이클로트론 동위원소의 생산 수율에 중요한 변수인 양성자에너지를 탄소에 입사시켜 입사빔의 Range와 에너지를 측정하는 방법을 제시하였다. 본 실험에서 사용된 양성자 빔의 양성자 에너지는 35 MeV와 50 MeV 사이였으며, 탄소 막은 두께 6.3mm, 밀도 $1.712 g/cm^3$를 사용하였다. 탄소 표적물을 $0.9^{\circ}$씩 스텝 모터를 사용하여 회전시킴으로 두께를 변화 시켜 공칭 에너지에 대한 Range를 측정함으로써 입사된 양성자의 에너지를 구하였고 이를 인출반경과 RF주파수를 바탕으로 상대론 적으로 계산된 에너지와 비교하였다.

  • PDF

An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing (공동주택의 기밀성능 평가 및 에너지 절감효과 분석)

  • Leigh, Seung-Bok
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.119-125
    • /
    • 1995
  • Since the using of heating energy associated with infiltration is significant in a building, the efforts to minimize the infiltration while ensuring minimum ventilation rates for various types of occupancy will be beneficial. In constrast to that many efforts have been made to reduce heat loss by improving thermal resistance of building envelope, little has been tried to reduce heat loss from infiltration. For achieving such an objective, measurement of air leakage rate will be pre-requisite as a diagnostic tool. A blower door system, a depressurization/pressurization method, was employed and it demonstrated a good potential for measuring airtightness performance of residential buildings. Based on the test results, annual energy savings for residential heating was estimated by reducing infiltration to a level of reasonably airtight or to a level of ASHRAE Standard 62-1989 for minimum ventilation.

  • PDF

수배전 시스템의 에너지 절약$\cdot$이용합리화 2. MDU브레이커를 사용한 전로감시 시스템

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.264
    • /
    • pp.79-83
    • /
    • 1998
  • 생에너지(에너지절약/이용합리화)를 실시하기 위해서는 환경국제규격 ISO14001에 기초한 환경매니지먼트 시스템에 따라 적극적인 추진이 필요하며, ''생에너지의 목표설정(P)'', ''감시 및 측정과 기록(c)'', ''개선(A)''의 P-D-C-A사이클에 대한 지속적인 활동이 중요하다. 전기량의 감시 및 측정과 기록(c)에 대해서도 전기설비 전체를 대상으로 해서는 개선점을 발견하기 힘들며, 보다 세밀한 피더별 관리의 경우가 효과를 거두기 쉽다. 그래서, 분기마다 부하설비별로 전기량을 감시, 측정하고 저코스트로 간단하게 기록할 수 있는 생에너지 지원기기가 필요하다. 그 하나가 ''MDU브레이커''로서 배선용차단기에 계측용 VT''CT와 계측표시유닛MDU(Measuring Display Unit)를 일체화한 제품이다. 대전류가 흐르는 배선용차단기와 서지$\cdot$노이즈를 싫어하는 계측기기인, 언뜻 보아 어울리지 않는 조합이지만 지난 20년 동안의 전자식차단기에 있어서 대전류에 가까운 과전류 검출회로를 정확하게 동작시켜온 경험을 살린 제품이다. 그 MDU브레이커를 사용한 전로감시시스템의 구성예로서 (1)퍼스텀과 시퀀서를 컨트롤러로 하여 MDU 브레이커가 100대 이상인 본격적인 것에서부터 (2)조작표시기로 간단하게 계측할 수 있는, MDU브레이커가 8대 전후인 소규모시스템까지 각종 방법에 대해 소개한다.

  • PDF

Time-series big data analytics software on IoT streaming data (빅데이터 기반 대용량 시계열 에너지 데이터 처리 시스템)

  • Kang, Jeonghoon;Yoo, June-Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.05a
    • /
    • pp.52-53
    • /
    • 2018
  • 본 논문은 에너지 빅데이터를 분석하기 위해 대용량의 시계열 데이터를 처리하는 시스템의 설계, 구축 방법을 제시한다. 이미 사용 중인 건물이나 공장의 에너지 효율화를 위해서 정부는 효율자원 시장 지원 사업을 수행하고 있다, 에너지 소비 설비에 따라 고효율 자원으로 변경 설치하는 데 필요한 자금의 일부를 지원하고 있다. 정부지원으로 고효율 설비로 변경함에 따라 실증 사이트에서는 측정 데이터를 수집하여, 효율화 정도를 파악하기 위한 에너지 데이터 분석 시스템을 구축하여 운영하였다. 해당 측정 정보는 IoT 전력량계를 통해 수집되며, 수집된 데이터는 클라우드 시스템에서 다양한 머신러닝 알고리즘에 적용되어, 에너지 소비 효율 평가에 필요한 성능 지표를 연산한다. 구현된 진단 시스템은 기축 건물의 에너지 효율향상 상황을 분석하는데 기여할 수 있다. 빅데이터 기반의 에너지 분석 기능을 사용하여 에너지 고효율 장비의 운영시간, 부하율 등의 효율성과 성능통계를 연산할 수 있다.

A Study on Energy Expenditure in Korean Adolescent Women (한국 청소년 여성의 에너지 소비량에 관한 연구)

  • 김유섭;오승호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.4
    • /
    • pp.367-373
    • /
    • 1993
  • A 4-week energy balance study was conducted to estimate the energy expenditure (EE) of 7 high school age girl, 15 to 16 year age, by measurement of energy intakes and changes in body energy (BE) content (intake/balance technique), keeping their normal living pattern and eating behavior. Gross energy intake (GE) and fecal energy (FE) loss was measured by bomb calorimetry. Urinary energy (UE) loss was calculated from nitrogen excreted. Fat mass (FM) was determined from body density estimated from skinfold thickness. Mean constitutional ratio of carbohydrate, protein and fat for the total energy intake was 70.1$\pm$1.8%, 12.2$\pm$0.7% and 17.7$\pm$2.0%, respectively, Fecal energy loss was 2.8% proportion of the gross energy intake. Mean daily metabolizable energy estimated by subtract fecal and urinary energy loss was 2022 $\pm$ 50㎉. Total body energy change estimated from body composition change over 28days was increased 2400 $\pm$ 950㎉ . Mean daily energy expenditure was 1958$\pm$87㎉ (39$\pm$2㎉ /kg of body weight).

  • PDF

High Energy Electron Dosimetry by Alanine/ESR Spectroscopy (Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정)

  • Chu, Sung-Sil
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1989
  • Dosimerty based on electron spin resonance (ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to 1 Gy. In water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies $(6\~21MeV)$ and therapeutic dose levels (1~60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15 MeV were higher by$2\~5\%$ than those calculated by nominal energy $C_E$ factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator.

  • PDF

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

Comparison of Electron Beam Dosimetries by Means of Several Kinds of Dosimeters (수종의 측정기에 의한 전자선의 선량 측정의 비교)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.93-100
    • /
    • 1989
  • Several combinations of measuring devices and phantoms were studied to measure electron beams. Silicon Pmt junction diode was used to find the dependence of depth dose profile on field size on axis of electron beam Depths of 50, 80 and $90\%$ doses increased with the field size for small fields. For some larger fields, they were nearly constant. The smallest of field sizes over which the parameters were constant was enlarged with increase of the energy of electron beams. Depth dose distributions on axis of electron beam of $10\times10cm^2$ field were studied with several combinations of measuring devices and phantoms. Cylindrical ion chamber could not be used for measurement of surface dose, and was not convenient for measurement of near surface region of 6MeV electron. With some exceptions, parameters agreed well with those studied by different devices and phantoms. Surface dose in some energies showed $4\%$ difference between maximum and minimum. For 18MeV, depths of 80 and $90\%$ doses were considerably shallower by film than by others. Parallel-plate ion chamber with polystyrene phamtom and silicon PN junction would be recommended for measurement of central axis depth dose of electron beams with considerably large field size. It is desirable not to use cylindrical ion chamber for the purpose of measurement of surface dose or near surface region for lower energy electron beam. It is questionable that film would be recommended for measurement of dose distribution of electron with high energy like as 18MeV.

  • PDF

Atmospheric Radiation, Albedo, Trunk Temperature, and Leaf Area of Meteorological Aspects in a Mixed Forest at Kwangneung Arboretum (광릉수목원 혼합림에서의 기상학적 관점의 대기복사, 알베도, 나무온도, 잎면적)

  • 김연희;조경숙;김현탁;엄향희;최병철
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.432-433
    • /
    • 2002
  • 지표면은 일사 에너지를 다른 에너지로 변환하여 군락 및 대기 운동에 원동력을 제공한다. 산림과 대기 사이에서 발생하는 에너지 교환을 이해하기 위해서는 대기복사, 알베도, 나무온도, 잎면적 등에 관한 조사가 필수적이다. 특히 태양 복사의 측정은 지표와 대기에서의 에너지 수지에 관한 가장 정확한 측정방법중 하나이다(Cho et al., 2002). (중략)

  • PDF