• Title/Summary/Keyword: 에너지 정의

Search Result 2,864, Processing Time 0.03 seconds

Active Vibration Control of Cantilever Beams Using PZT Actuators (PZT Actuator를 이용한 외팔보의 능동진동제어)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1293-1300
    • /
    • 2008
  • This paper presents an active vibration control of cantilever beams under disturbances by a primary force. A direct velocity feedback control using a pair of PZT actuator and a velocity sensor is considered. Variation of the stability and performance with the locations of the sensor/actuator pair is investigated. It is found that the maximum gain varies with the locations of the sensor/actuator pair significantly. The maximum gain shows a symmetric distribution along the beam length with respect to the center point, although the boundary condition of the beam is unsymmetric. The control performance is affected by the location of the primary force as well as the location of the sensor/actuator pair. The active control system can more effectively reduce the vibration when the primary force is located close to the fixed boundary.

Environmental Impact Assessment in LCA Using Analytic Network Process (네트워크구조 의사결정기법을 이용한 LCA 환경영향평가)

  • 강희정
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.612-620
    • /
    • 1999
  • Environmental impact assessment in the step of the Life Cycle Assessment (LCA) measures relative values of importance or weight of the environmental load characterized in the inventory analysis. The weight measurements are used to evaluate the environmental load or the effect of the industrial product or technology. In this paper the Analytic Network Prpcess (ANP) is introduced to calculate a relative weighting of the environmental impact. The ANP is considered as one of the useful decision making framework and allow for more complex interrelationships, feedback, and inner/outer dependence among the decision level and factors. The weighting from the ANP may applied to obtain the overall evaluation value of environmental load.

  • PDF

auto-pilot flight for UAVs using public Data (공공 데이터를 이용한 UAV 자동경로비행)

  • Park, KyungSeok;Kim, MinJun;Oyindamola, Owolabi Ganiyat;LIU, HUIYU;Kim, SungHo
    • Annual Conference of KIPS
    • /
    • 2019.05a
    • /
    • pp.242-245
    • /
    • 2019
  • 움직이는 UAV는 많은 위치에너지와 운동에너지를 가지므로 지상으로 추락하는 경우 많은 충격량을 가질 수 있다. 이는 인명피해로 연결될 수 있기 때문에 본 논문에서는 UAV 비행경로 상의 인구밀집지역을 위험구역으로 정의하였다. 기존의 UAV 경로비행은 사용자에 의해 미리 설정된 경로만을 운행하는 수동적인 형태였다. 일부 UAV는 경로비행 중 장애물을 회피하는 시스템 등 안전기능을 포함하고 있지만, 비행환경변화에 대응하기에는 부족하다. UAV 경로비행에 공공 데이터를 활용할 경우, 위험구역을 검출하고 회피비행을 수행할 수 있어서 비행환경변화에 대한 대응이 향상될 수 있다. 따라서 본 논문에서는 수집된 데이터를 활용하여 위험구역을 회피하는 최적경로 비행 방안을 제안한다. 실험결과, 제안하는 자동경로비행에서 목적지와 목적지에 따른 경로를 지정할 경우, 위험지역을 스스로 판단하여 최적 우회경로로 비행하는 것을 확인하였다. 추후 회피방안에 따라 비행하여 획득하는 영상의 질적 만족도를 높일 수 있는 방안을 연구할 예정이다.

Efficient Power Management Mechanism considering Network Characteristic in 802.11 (802.11에서 네트워크 특성을 고려한 전력 감소 기법)

  • Nam, Jae-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.475-477
    • /
    • 2010
  • In the power saving mechanism specified in IEEE 802.11, all node use the sam ATIM window size. Since the ATIM window size critically affects throughput and energy consumption, a fixed ATIM window does not perform well in all situations. This paper proposes the efficient power management mechanism considering network characteristic in 802.11. To reflect the network characteristic, the paper uses th (m,k)-firm deadline technique. Simulation result shows that proposed mechanism outperforms the IEEE 802.11 power saving mechanism in terms of the amount of power consumed.

  • PDF

Occupants Control Patterns of Indoor Shading Devices in Apartment Buildings (공동주택 거주자의 실내 차양장치 사용행태에 관한 연구)

  • Lee, Yoon Jeong;Kim, Jeong-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.12-20
    • /
    • 2014
  • There is no comprehensive consensus of the control patterns people op::rate shadings or the motivating factors that influence their decisions. Patterns of shading devices use can affect the energy consumption of buildings. Therefore, this study aims to analyze shading device usage patterns based on the physical factors that can affect occupants behavior. First, control patterns of indoor shading devices in apartment buildings were monitored by taking pictures. Next, frequency of shading device use together with their shading portions was analyzed based on two physical factors such as window orientation and floor level. The results showed that about 35% of the monitored apartment buildings utilized indoor shading devices. Also, the south-facing apartments were more dynamically used than their east-facing counterparts. On the contrary, there was no general trend in regards to the shading operation patterns.

Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines (소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향)

  • Jeong, Houi-Gab;Lee, Seung-Ho;Kwon, Soon-Duck
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

Performance Characteristics of a Heat Pipe Having Water-Ethanol Mixture as Working Fluid for Evacuated Solar Collectors (물-에탄올 혼합물을 작동유체로 하는 진공관형 태양열 집열기용 히트파이프의 작동특성)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.78-84
    • /
    • 2008
  • Heat pipes are considered to be promising candidates to enhance the heat transport capability of evacuated solar collectors in a wide temperature range. The working fluid must be selected properly considering various operating conditions of heat pipes for medium-high temperature range to avoid dry-out, local overheating, and frozen failure. The advantage of using binary mixture as heat pipe working fluid is that it can extend operating temperature range of the system as it can overcome operating temperature limit of a single fluid. Various operating temperature ranges were imposed in the experiments to simulate the actual operation of solar collectors using water-ethanol binary mixture. Tests were conducted for the coolant temperature range of -10$^{\circ}C$ to 120$^{\circ}C$, and mixing ratio range was from 0 to 1 based on mass fraction.

Productivity Analysis for Multi-Wells Depressurization of Gas Hydrate Bearing Sediments in Ulleung Basin, East Sea of Korea (동해 울릉분지 가스하이드레이트 퇴적층 내 다중정 감압에 따른 생산성 분석)

  • Moon, Seo-Yoon;Shin, Hyo-Jin;Lim, Jong-Se
    • Ocean and Polar Research
    • /
    • v.43 no.4
    • /
    • pp.295-306
    • /
    • 2021
  • A field scale productivity analysis is required for the development of gas hydrate in marine sedimentary layers to verify the field applicability of production techniques and to improve productivity. In this study, the productivity resulting from the application of depressurization using multi-wells for the development of gas hydrate in the Ulleung Basin, East Sea of Korea, was determined. A numerical analysis model reflecting the conditions of candidate sites for the Ulleung Basin was constructed, and the productivity and dissociation behavior were comparatively analyzed. The pressure propagation and gas hydrate dissociation region by the multi-wells were wider and the productivity was higher than that of a single well. Different depressurization effects according to the spacing of multi-wells affected productivity. The results provide basic data for productivity analysis when establishing a field test production plan for the Ulleung Basin.

Performance of the Geothermal Heat Pump Using HFC32 Refrigerant (HFC32 냉매를 사용한 지열원 히트펌프의 성능 특성)

  • PARK, YONG-JUNG;PARK, BYUNG-DUCK
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.4
    • /
    • pp.369-375
    • /
    • 2019
  • Air conditioners adopting high energy efficiency and low global warming potential (GWP) refrigerant are being developed globally. In case of commercial air conditioner, R32 with lower GWP than R410A is attracting industrial attentions. In this study, the performance of water-to-water geothermal heat pump adopting R32 is compared with that of the heat pump using R410A. By using R32 instead of R410A, heating capacity and COP in heating standard condition can be increased by 8.8% and 6.3% respectively. Also, cooling capacity and COP in cooling standard condition can be increased by 5.3% and 3.1% respectively by using R32. But in case of using R32, systemic improvements are required to decrease discharge temperature of compressor since discharge temperature rises abnormally in heating operations.

Optimal firing method of the Celadon using gas kiln (가스가마를 사용한 최적의 청자 소성방법 연구)

  • Kim, Sanggon
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.55-62
    • /
    • 2019
  • The purpose of this research is to find the optimum combustion conditions for the celadon using a gas kiln. It is clearly defined by the amount of CO gas in the kiln that it is fired in the commonly used oxidation and reduction atmosphere. As a result, while celadon was fired at $1250^{\circ}C$, oxidation happened when the amount of CO was 0~4,500 PPM, a neutral condition happened when the of CO was 4,500~25,000PPM and a reducing process was happened when the of CO was more that 25,000PPM. To reduce gas and firing time while keeping uniformly the firing temperature and firing condition of the gas kiln, you can partially block the gas corridor and adjust it as a damper. This adjustment reduces gas consumption by 40% and shortens the firing time by 1 hour.