• Title/Summary/Keyword: 에너지 수요 정보

Search Result 3,083, Processing Time 0.037 seconds

A Research of LEACH Protocol improved Mobility and Connectivity on WSN using Feature of AOMDV and Vibration Sensor (AOMDV의 특성과 진동 센서를 적용한 이동성과 연결성이 개선된 WSN용 LEACH 프로토콜 연구)

  • Lee, Yang-Min;Won, Joon-We;Cha, Mi-Yang;Lee, Jae-Kee
    • The KIPS Transactions:PartC
    • /
    • v.18C no.3
    • /
    • pp.167-178
    • /
    • 2011
  • As the growth of ubiquitous services, various types of ad hoc networks have emerged. In particular, wireless sensor networks (WSN) and mobile ad hoc networks (MANET) are widely known ad hoc networks, but there are also other kinds of wireless ad hoc networks in which the characteristics of the aforementioned two network types are mixed together. This paper proposes a variant of the Low Energy Adaptive Cluster Hierarchy (LEACH) routing protocol modified to be suitable in such a combined network environment. That is, the proposed routing protocol provides node detection and route discovery/maintenance in a network with a large number of mobile sensor nodes, while preserving node mobility, network connectivity, and energy efficiency. The proposed routing protocol is implemented with a multi-hop multi-path algorithm, a topology reconfiguration technique using node movement estimation and vibration sensors, and an efficient path selection and data transmission technique for a great many moving nodes. In the experiments, the performance of the proposed protocol is demonstrated by comparing it to the conventional LEACH protocol.

An Efficient WLAN Device Power Control Technique for Streaming Multimedia Contents over Mobile IP Storage (모바일 IP 스토리지 상에서 멀티미디어 컨텐츠 실행을 위한 효율적인 무선랜 장치 전력제어 기법)

  • Nam, Young-Jin;Choi, Min-Seok
    • The KIPS Transactions:PartA
    • /
    • v.16A no.5
    • /
    • pp.357-368
    • /
    • 2009
  • Mobile IP storage has been proposed to overcome storage limitation in the flash memory and hard disks. It provides almost capacity-free space for mobile devices over wireless IP networks. However, battery lifetime of the mobile devices is reduced rapidly because of power consumption with continuous use of a WLAN device when multimedia contents are being streamed through the mobile IP storage. This paper proposes an energy-efficient WLAN device power control technique for streaming multimedia contents with the mobile IP storage. The proposed technique consists of a prefetch buffer input/output module, a WLAN device power control module, and a reconfigurable prefetch buffer module. Besides, it adaptively determines the size of the prefetch buffer according to a quality of the multimedia contents, and it dynamically controls the power mode of the WLAN device on the basis of power on-off operations while streaming the multimedia contents. We evaluate the performance of the proposed technique on a PXA270-based mobile device that employs the embedded linux 2.6.11, Intel iSCSI reference codes, and a WLAN device. Extensive experiments reveal that the proposed technique can save the energy consumption of the WLAN device up to 8.5 times with QVGA multimedia contents, as compared with no power control.

Comparison of meridians electric response property for laser and acupuncture stimulation (레이저자극과 수기자극에 대한 경락전기반응 특성비교)

  • Lee, Yong-Heum;Ryu, Yeon-Hang;Jung, Byoung-Jo;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2335-2342
    • /
    • 2007
  • Laser stimulation has been widely studied and used in clinic. However, electrical response by laser stimulation on meridians has not been investigated. In this study, we compared electric potential of laser and acupuncture stimulation on meridians. We measured electric potential variation at acupoints(Samgan(LI3) and Hapgok(LI4)) on Large Intestine Meridian. In laser stimulation results, average peak electric potential is very low($7.53{\pm}3.44{\mu}V$) for before and after stimulation. However, acupuncture stimulation was performed in ground connection condition and resulted in huge variation of average peak electric potential($2.65{\pm}1.53mV$). That is, the intensity and pattern of electric potential were dependent on the ground connection condition and individual. Also, the electric potential pattern was very similar to the pattern of electric charge and discharge of capacitor. The acupuncture stimulation using a insulating needle resulted in lower average peak electric potential variation($0.25{\pm}0.16mV$) than that of acupuncture stimulation. It might present little electrical response of acupuncture stimulation using insulating needles. In point of electrical response, the laser stimulation was determined to be no acupuncture effect at meridian. Acupuncture stimulation seems to be most effective method to induce electrical response at meridians. The procedure and effect of acupuncture might be considered as energy consensus phenomenon by transportation of bio-ion charge between a practitioner and patient.

Independent I/O Relay Class Design Using Modbus Protocol for Embedded Systems

  • Kim, Ki-Su;Lee, Jong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.1-8
    • /
    • 2020
  • Communication between system modules is applied using the Modbus protocol in industrial sites including smart factories, industrial drones, building energy management systems, PLCs, ships, trains, and airplanes. The existing Modbus was used for serial communication, but the recent Modbus protocol is used for TCP/IP communication.The Modbus protocol supports RTU, TCP and ASCII, and implements and uses protocols in embedded systems. However, the transmission I/O devices for RTU, TCP, and ASCII-based protocols may differ. For example, RTU and ASCII communications transmit on a serial-based communication protocol, but in some cases, Ethernet TCP/IP transmission is required. In particular, since the C language (object-oriented) is used in embedded systems, the complexity of source code related to I/O registers increases. In this study, we designed software that can logically separate I/O functions from embedded devices, and designed the execution logic of each instance requiring I/O processing through a delegate class instance with Modbus RTU, TCP, and ASCII protocol generation. We designed and experimented with software that can separate communication I/O processing and logical execution logic for each instance.

A Study on the Automation of MVDC System-Linked Digital Substation (MVDC 시스템연계 디지털변전소 자동화 연구)

  • Jang, Soon Ho;Koo, Ja Ik;Mun, Cho Rong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.199-204
    • /
    • 2021
  • Digital substation refers to a substation that digitizes functions and communication methods of power facilities such as monitoring, measuring, control, protection, and operation based on IEC 61850, an international standard for the purpose of intelligent power grids. Based on the intelligent operating system, efficient monitoring and control of power facilities is possible, and automatic recovery function and remote control are possible in the event of an accident, enabling rapid power failure recovery. With the development of digital technology and the expansion of the introduction of eco-friendly renewable energy and electric vehicles, the spread of direct current distribution systems is expected to expand. MVDC is a system that utilizes direct current lines with voltage levels and transmission capacities between HVDCs applied to conventional transmission systems and LVDCs from consumers. Converting existing lines in substations, where most power equipment is alternating current centric, to direct current lines will reduce transmission losses and ensure greater current capacity. The process bus of a digital substation is a communication network consisting of communication equipment such as Ethernet switches that connect installed devices between bay level and process level. For MVDC linkage to existing digital substations, the process level was divided into two buses: AC and DC, and a system that can be comprehensively managed in conjunction with diagnostic IEDs as well as surveillance and control was proposed.

Analysis of Scope 3 Management Characteristics for the Best Greenhouse Gas Management Companies by Utilizing CDP Data (CDP 정보를 활용한 국내외 온실가스 관리 우수기업의 Scope 3 관리수준 분석)

  • Roh, Dae-Yong;Lee, Jae-Hyung;Kim, Yong-Sang;Lee, Woo-Kyun
    • Journal of Climate Change Research
    • /
    • v.3 no.4
    • /
    • pp.225-234
    • /
    • 2012
  • This study analyzes domestic and overseas companies' Scope 3 verification, level of management, source and industry characteristics based on the responses of domestic excellent companies and rated 90 points or more global excellent companies which are included in CDP Korea 200 and CDP Global 500. The result of analysis conveys that global excellent companies' Scope 3 management source achieved the average of 2.7 which is one more than domestic excellent companies', according to the Scope 3 guideline of World Resource Institute and World Business Council of Sustainable Development. For domestic companies are tend to focus on business travel, employee commuting, etc. but didn't manage capital goods, leased assets and investments. Global companies' Scope 3 source is similar to domestic companies but shows more actively managing on investment and use of sold products. It seems that domestic companies should actively develop Scope 3 source especially for the capital related items and respond to the future regulations on inter-enterprise management through the Scope 3.

Comparison of the CO2 Emissions Estimations among Four Tier Methods for the Facilities from Different Industrial Sectors in Korea (국내 산업 부문에 대한 온실가스 배출량 산정 방법 결과 비교)

  • Kim, Hee Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.195-209
    • /
    • 2012
  • There are four differentiated levels to quantify the amount of greenhouse gas emissions from a facility, which are Tier 1 to 4 based on the IPCC guidelines. In this study, the emission estimates from all tier levels were calculated to compare their total $CO_2$ emission results among themselves for seven facilities, including three sectors of electricity generation, municipal solid waste incineration, and cement manufacturing for three months between February and May 2011. Generally the measured $CO_2$ emissions by Tier 4 were higher than the calculated $CO_2$ emissions by Tier 3, which had been also observed for the power plants in the USA. It was found out that to obtain more reliable estimation for Tier 3, accurate analysis of the composition of the fuel used should be carried out. It was suggested that further refinement on the administrative guidelines be made to make it more robust.

Technical Development for Extraction of Discontinuities in Rock Mass Using LiDAR (LiDAR를 이용한 암반 불연속면 추출 기술의 개발 현황)

  • Lee, Hyeon-woo;Kim, Byung-ryeol;Choi, Sung-oong
    • Tunnel and Underground Space
    • /
    • v.31 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Rock mass classification for construction of underground facilities is essential to secure their stabilities. Therefore, the reliable values for rock mass classification from the precise information on rock discontinuities are most important factors, because rock mass discontinuities can affect exclusively on the physical and mechanical properties of rock mass. The conventional classification operation for rock mass has been usually performed by hand mapping. However, there have been many issues for its precision and reliability; for instance, in large-scale survey area for regional geological survey, or rock mass classification operation by non-professional engineers. For these reasons, automated rock mass classification using LiDAR becomes popular for obtaining the quick and precise information. But there are several suggested algorithms for analyzing the rock mass discontinuities from point cloud data by LiDAR scanning, and it is known that the different algorithm gives usually different solution. Also, it is not simple to obtain the exact same value to hand mapping. In this paper, several discontinuity extract algorithms have been explained, and their processes for extracting rock mass discontinuities have been simulated for real rock bench. The application process for several algorithms is anticipated to be a good reference for future researches on extracting rock mass discontinuities from digital point cloud data by laser scanner, such as LiDAR.

Development and Effectiveness Evaluation of Acupressure Bed with Variable Type Bogie (변동형 대차 구동방식의 지압 침대 개발 및 유효성 평가)

  • Heo, Sung-Phil;Park, Se-Jin;Ahn, Do-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.6
    • /
    • pp.47-54
    • /
    • 2020
  • The acupressure is a treatment that applies pressure to certain parts of the body and has been mainly used for pain relief in the field of oriental medicine. However, the treatment effect is often different depending on the practitioner's ability, experience, and physical strength, so standardized acupressure is needed. In this regard, the equipment is being released, but this is mainly a rolling massage method, which reduces energy concentration and poses a risk of injury. Therefore, in this study, a device that provides vertical acupressure based on variable bogie (wheel truck) was implemented. As a result of experimenting with load and body pressure distribution and desirability to validate the device's bearing pressure, the acupressure rod held up to 150kg, the body pressure ratio was measured lower than the body pressure ratio of the comparison item in section 0%

The association between body composition and bone mineral density in subjects aged 50 years or older in men and postmenopausal women in Korea

  • Cho, Jeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.8
    • /
    • pp.209-220
    • /
    • 2021
  • The effect of body composition such as lean mass and fat mass on bone mineral density (BMD) is complex and still controversial. In this study, we investigated the relationship between body composition and bone mineral density using nation-wide data from 2008 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES) in 2,139 men and 2,193 postmenopausal women aged 50 years or older. Subjects with history of medication for osteoporosis or with diseases or malignancy affecting bone metabolism were excluded. Data of anthropometric measurements and demographic characteristics were collected by trained examiner. Fasting blood sample was obtained for blood chemistry analysis. BMD of the lumbar spine, total femur, and femoral neck, and body composition such as total lean mass (TLM), total fat mass (TFM), truncal fat mass (TrFM) were measured using dual-energy X-ray absorptiometry (DXA). There were significant positive correlations between body composition indices such as lean mass and fat mass with BMD. In multiple regression analysis, TLM was positively associated with BMD after adjusting age, body mass index, monthly house income, education level, physical activity, daily calcium intake and vitamin D concentration in both men and postmenopausal women. BMD at lumbar spine and femur in lowest quartile of TLM was significantly lower than other quartiles after adjusting those confounding factors in both gender. TrFM was negatively associated with total femur BMD in male and femur neck BMD in postmenopausal women after adjusting confounding factors. In conclusion, TLM is very important factor in maintaining BMD in subjects aged 50 years or older in men and postmenopausal women.