• Title/Summary/Keyword: 에너지 산출

Search Result 766, Processing Time 0.023 seconds

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.

Ictal Cerebral Perfusion Patterns in Partial Epilepsy: SPECT Subtraction (부분적 간질에서 SPECT Subtraction을 이용한 발작 중 뇌혈류 변화에 대한 연구)

  • Lee, Hyang-Woon;Hong, Seung-Bong;Tae, Woo-Suk;Kim, Sang-Eun;Seo, Dae-Won;Jeong, Seung-Cheol;Yi, Ji-Young;Hong, Seung-Chyul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.169-182
    • /
    • 2000
  • Purpose: To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Materials and Methods: Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. Results: The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Conclusion: Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  • PDF

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

Effect of Contrast-Enhanced $^{18}F$-FDG PET/CT on Measurements of Whole Body Bone Mineral Density and Body Composition by Dual-Energy X-Ray Absorptiometry (조영증강 $^{18}F$-FDG PET/CT가 이중에너지 X-선 흡수 계측법을 이용한 골밀도 및 체성분 측정에 미치는 영향)

  • Kim, Seong Su;Lee, Sun Do;Lee, Nam Ju;Shin, Yong Cheol;Mo, Eun Hee;Lee, Chun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.7-11
    • /
    • 2012
  • Purpose : The effect of concomitant use of $^{18}F$-FDG and intravenous contrast agent (CA) on dual-energy X-ray absorptiometry (DXA), was rarely reported. We had investigated these potentially confounding effects. Materials and Methods : Twenty-two patients had undergone DXA before and immediately after $^{18}F$-FDG PET/CT scans. Two DXA and 1 PET/CT scans had performed within one-day. $^{18}F$-FDG PET/CT scans had been performed with CA in 17 patients and without CA in 5 patients. Whole body bone mineral content (BMC), whole body bone mineral density (BMD), total fat mass (TFM), and lean body mass (LBM) were measured by DXA scanner before and after the $^{18}F$-FDG PET/CT scans. Results : BMC, BMD, TFM and LBM had significantly affected by $^{18}F$-FDG PET/CT with CA (BMC, +13.7%, from $2061.3{\pm}393.7$ to $2343.4{\pm}373.3$; BMD, +9.3%, from $1.07{\pm}0.09$ to $1.17{\pm}0.08$; TFM, -34.1%, from $17052.1{\pm}4049.9$ to $11237.1{\pm}2990.3$; LBM, +13.6%, from $45834.5{\pm}5662.1$ to $52094.0{\pm}6335.4$). However, $^{18}F$-FDG PET/CT without CA had no effect on the measurement of DXA (BMC, +2.4%, from $2197.7{\pm}391.6$ to $2251.5{\pm}380.9$; BMD, +1.8%, from $1.13{\pm}0.09$ to $1.15{\pm}0.07$; TFM, -6.8%, from $14585.6{\pm}3455.9$ to $13591.3{\pm}4351.4$; LBM, +2.2%, from $47360.5{\pm}8381.8$ to $48441.1{\pm}8488.1$). Conclusion : The measurements of DXA are affected by using CA. However, DXA scans might be unaffected by the presence of $^{18}F$-FDG administered for PET/CT.

  • PDF

Evaluation of Standardized Uptake Value applying Prompt Gamma Correction on 68Ga-DOTATOC PET/CT Image (68Ga-DOTATOC PET/CT에서 Prompt Gamma Correction을 적용한 SUV의 평가)

  • Yoon, Seok Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • $^{68}Ga$ was eluted from a $^{68}Ge/^{68}Ga$ radionuclide generator. $^{68}Ga$ decays into $^{68}Zn$, with a half life=67.8min. The decay is 88.9 % by ${\beta}$+ and 11.1 % by EC. The main ${\beta}$+ decay (87.7 %) is to the ground level of $^{68}Zn$ and it is a pure positron emission branch. A small fraction decays ${\beta}$+ (1.2 %) into an excited level of $^{68}Zn$, which promptly decays into the ground level with a ${\gamma}$ (1.077 Mev). This can constitute prompt gamma contamination in the PET data, if the 1.077 Mev ${\gamma}$ has a scatter interaction in the patient, and generates a lower energy ${\gamma}$ in coincidence with the positron annihilation pair. The purpose of this study was to evaluate standardized uptake value(SUV) before and after applying prompt gamma rays correction on $^{68}Ga$-DOTATOC PET/CT image. Fifty patient underwent PET/CT 1 hour after injection of the $^{68}Ga$-DOTATOC. The SUVmax and SUVmean of lesions and normal tissues (Pituitary, Lung, Liver, Spleen, Kidney, Intestine) were evaluated before and after applying prompt gamma correction on $^{68}Ga$-DOTATOC PET/CT image. Additionally, the SUVmax of each lesions and SUVmean of the soft tissues were measured on images. and target to background ratios (TBR) were calculated as quantitative indices. Among 15 patients, 25 of lesions (Pancreas, Liver, Thoracic Spine, Brain) with increased uptake on $^{68}Ga$-DOTATOC PET/CT image. SUVmax and SUVmean were increased in lesion site and normal tissue after prompt gamma rays correction. TBR was $51.51{\pm}49.28$ and $55.50{\pm}53.12$ before and after prompt gamma rays correction, respectively. (p<0.0001)

A Study on the Relationship between Milk Consumption, Dietary Nutrient Intake and Physical Strength of Adolescents in Middle and Small-Sized Cities in Korea for Dietary Education of Home Economics Subject at Middle and High Schools (중등학교 가정교과 식생활교육을 위한 청소년의 우유 섭취, 영양 섭취 및 체력과의 관계 연구)

  • Kim, Sun-Hyo
    • Journal of Korean Home Economics Education Association
    • /
    • v.28 no.4
    • /
    • pp.159-167
    • /
    • 2016
  • This study was performed to investigate the relationship between milk consumption, dietary nutrient intake, and physical strength in Korean adolescents for dietary education of home economics subject at middle and high schools. Intake of milk and milk products, that of dietary nutrients, and physical strength records were surveyed for 298 high school students resided in small and medium-sized cities in Korea. Intake of milk and milk products was collected from three-day dietary survey, and daily dairy equivalent of calcium was calculated by dividing daily calcium intake(mg) from milk and milk products by calcium content(200 mg) of 200 mL milk. Dietary survey was performed during three days including two-weekdays and one-weekend by food record method. Dietary nutrient intake was analyzed by CAN-Pro 3.0. Physical strength records were offered from subjects' schools. Subjects were divided into low intake group(${\leq}0.29/d$), medium intake group(0.30-0.78/d) and high intake group(0.79-5.66/d) according to daily mean dairy equivalent of calcium taken by them, and most of them consumed milk and milk products less than '2' of the recommended value. Daily mean dairy equivalent of calcium was significantly related with high records of '50 m running' and 'stand long jump'(p<0.05), however it was not related with other records of physical strength. Intakes of energy, carbohydrate, protein, fat, calcium, phosphorus, iron, zinc, thiamin, riboflavin, niacin and vitamin E were significantly correlated with high record of '50 m running'(p<0.01). Intakes of nutrients were related with '50 m running' except fat were significantly correlated with high record of 'stand long jump'(p<0.05). Intakes of protein, phosphorus, iron, zinc, vitamin A, $B_6$ and E were significantly correlated with high record of 'long distance running'(p<0.05). In conclusion intake of milk and milk products was related with physical strength records('50 m running' and 'stand long jump') and intakes of most nutrients including energy nutrient, vitamin and mineral were correlated with physical strength records('50 m running', 'stand long jump' and 'long distance running') in Korean adolescents. Therefore, optimal consumption of milk and various nutrients for balanced nutrition during adolescents should be emphasized in dietary education of home economics subject for their strong physical strength.

Dietary Fiber Intake of Middle School Students in Chungbuk Area and Development of Food Frequency Questionnaire (충북지역 중학생의 식이섬유 섭취 실태 및 식품섭취빈도조사지 개발)

  • Kim, Young-Hye;Kang, Yu-Ju;Lee, In-Seon;Kim, Hyang-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • This study aimed to offer groundwork for grasp and evaluation of nutritional status and dietary fiber intake through 24-hr recall method among middle school students in Chungbuk area. In addition, this study attempted to develop food frequency questionnaire (FFQ) for dietary fiber intake. Average calorie intake per person a day was 2035.6 kcal for boys, and 1876.7 kcal for girls which were 75.4% and 93.8% of estimated energy requirement (EER), respectively. Percent estimated average requirements (%EAR) of calcium, iron and folate were the lowest showing 34.3%, 54.2%, 67.5% for boys and 36.6%, 59.2%, 64.4% for girls, respectively. Average dietary fiber intake per day was $17.6\pm5.3$ g for boys and $16.5\pm4.8$ g for girls which indicate 54.8% and 68.8% of adequate intake (AI), respectively. The main food sources of dietary fiber were polished rice and kimchi. The main food source groups were vegetables, cereals and their products were fruits, seaweeds in the order named, indicating 68.44% total dietary fiber intake from vegetables and cereals. From preliminary 39 food items, 19 food items were selected to derive the correlation coefficient of each food item between 24-hr recall and FFQ method. Correlation coefficient was increased from 0.71 to 0.78 with significant level of p<0.01 after adjustment of FFQ from 39 items to 19 items set. Percentage of classifying subjects into the same levels by food frequency questionnaire and 24-hr recall based on joints classification quartile Kappa value was evaluated. Agreement was highest in the second lowest group showing percentage to correspond rose from 90.2% to 92.4% and Kappa value of 0.54 to 0.59. Consequently, FFQ developed in this study would be useful for estimating the groups which show low intake.

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF

Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT (단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정)

  • Lee, Jeong-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.382-390
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the accuracy of radioactivity quantitation in Tc-99m SPECT by using combined scatter and attenuation correction. Materials and Methods: A cylindrical phantom which simulates tumors (T) and normal tissue (B) was filled with varying activity ratios of Tc-99m. We acquired emission scans of the phantom using a three-headed SPECT system (Trionix, Inc.) with two energy windows (photopeak window: $126{\sim}154keV$ and scatter window: $101{\sim}123keV$). We performed the scatter correction with dual-energy window subtraction method (k=0.4) and Chang attenuation correction. Three sets of SPECT images were reconstructed using combined scatter and attenuation correction (SC+AC), attenuation correction (AC) and without any correction (NONE). We compared T/B ratio, image contrast [(T-B)/(T+B)] and absolute radioactivity with true values. Results: SC+AC images had the highest mean values of T/B ratios. Image contrast was 0.92 in SC+AC, which was close to the true value of 1, and higher than AC (0.77) or NONE (0.80). Errors of true activity by SPECT images ranged from 1 to 11% for SC+AC, $22{\sim}47%$ for AC, and $2{\sim}16%$ for NONE in a phantom which was located 2.4cm from the phantom surface. In a phantom located 10.0cm from the surface, SC+AC underestimated by 24%, NONE 40%. However, AC overestimated by 10%. Conclusion: We conclude that accurate SPECT activity quantitation of Tc-99m distribution can be achieved by dual window scatter correction combind with attenuation correction.

  • PDF

Air Sampling and Isotope Analyses of Water Vapor and CO2 using Multi-Level Profile System (다중연직농도시스템(Multi-Level Profile System)을 이용한 수증기와 이산화탄소 시료채취 및 안정동위원소 조성 분석)

  • Lee, Dong-Ho;Kim, Su-Jin;Cheon, Jung-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The multi-level $H_2O/CO_2$ profile system has been widely used to quantify the storage and advection effects on energy and mass fluxes measured by eddy covariance systems. In this study, we expanded the utility of the profile system by accommodating air sampling devices for isotope analyses of water vapor and $CO_2$. A pre-evacuated 2L glass flask was connected to the discharge of an Infrared Gas Analyzer (IRGA) of the profile system so that airs with known concentration of $H_2O$ and $CO_2$ can be sampled. To test the performance of this sampling system, we sampled airs from 8 levels (from 0.1 to 40 m) at the KoFlux tower of Gwangneung deciduous forest, Korea. Air samples in the 2L flask were separated into its component gases and pure $H_2O$ and $CO_2$ were extracted by using a vacuum extraction line. This novel technique successfully produced vertical profiles of ${\delta}D$ of $H_2O$ and ${\delta}^{13}C$ of $CO_2$ in a mature forest, and estimated ${\delta}D$ of evapotranspiration (${\delta}D_{ET}$) and ${\delta}^{13}C$ of $CO_2$ from ecosystem respiration (${\delta}^{13}C_{resp}$) by using Keeling plots. While technical improvement is still required in various aspects, our sampling system has two major advantages over other proposed techniques. First, it is cost effective since our system uses the existing structure of the profile system. Second, both $CO_2$ and $H_2O$ can be sampled simultaneously so that net ecosystem exchange of $H_2O$ and $CO_2$ can be partitioned at the same temporal resolution, which will improve our understanding of the coupling between water and carbon cycles in terrestrial ecosystems.