• Title/Summary/Keyword: 에너지 변조 필터

Search Result 11, Processing Time 0.031 seconds

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

A Study on the Performance Improvement for UWB Ranging in Multipath Environments by Modified Linear FM Signals (선형 주파수 변조 신호의 부엽 제거를 통한 다중 경로 환경에서의 UWB 위치 추정 성능 향상 기법)

  • Lee Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.6 s.109
    • /
    • pp.587-596
    • /
    • 2006
  • Recently a new spectrum ruling has been proposed for UWB(Ultra-Wideband) communication applications. The new proposal is expected to reduce the usable UWB spectrum significantly and may cause to weaken the unique advantages of the UWB pulses such as high resolution synchronizations and robustness to the multipath effects. In this paper, we investigate the performance degradation caused by the reduced UWB spectrum. As a means to overcome the performance degradation, a modified discrete linear frequency modulation technique is proposed. We show that, when multipath components are present in the received signal, the proposed method exhibits superior performances in terms of pulse detection efficiency and range resolutions.

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

A Current-fed High Frequency Link Direct DC-AC Converter for Fuel Cell Power Source (연료전지용 전류형 고주파 링크 DC-AC 컨버터)

  • Song, Yu-Jin;Chung, Se-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.102-106
    • /
    • 2005
  • 본 논문에서는 연료전지 전원시스템에 적합한 전류형 고주파 링크 DC-AC 컨버터를 제안한다. 제안된 전류형 고주파 링크 DC-AC 컨버터는 전류형 풀-브릿지 인버터, 능동 고조파 필터, 고주파 링크 변압기, 사이클로 컨버터로 구성된다. 1차측의 전류형 고주파 풀-브릿지 인버터는 정현파 PWM에 의해 변조된 전류펄스를 영전류 스위칭과 함께 발생시키고 두 개의 양방향 스위치와 출력 필터 캐패시터만으로 구성된 사이클로 컨버터는 분리형 단상 60Hz 정현파 전압을 출력한다. 입력단에 연결된 능동 고조파 필터는 연료전지로부터 유기된 저고조파 전류를 배터리 또는 수퍼캐패시터같은 장시간의 에너지 저장장치 없이 제거한다.

  • PDF

An Audio Watermarking Method Using the Attribute of the Tonal Masker (토널 마스커 특성을 이용한 오디오 워터마킹)

  • 이희숙;이우선
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.367-374
    • /
    • 2003
  • In this paper, we propose an audio watermarking method using the attribute of tonal masker. First, the attribute of tonal masker as an audio watermarking attribute is analyzed. According to existing researches, it is possible to be imperceptible modulation for the energies of the frequencies that compose a tonal masker. And when the relation between the tone energy and the left or right frequency energy after various signal processing is compared with the one before the processing, very few changes are showed. We propose an audio watermarking method using these attributes of tonal masker. A watermark bit is embedded by the modulation of the difference between the two neighboring frequency energies of a tone. In the detection, the modulated the tonal masker is searched using the key wed in the embedding without original audio and the embedded watermark bit is detected. After each attack of noise insertion, band-pass filtering, re-sampling, compression, echo transform and equalization, the detection error ratios of the proposed method were average 0.11%, 1.26% for Classics and Pops. And the SDG(Subjective Diff-Grades) scale evaluation of the sound quality of the watermarked audio result in the average SDG -0.31.

Design of an LCL-Filter for Grid-Connected Three-Level Inverter System (계통 연계형 3-레벨 인버터 시스템을 위한 LCL-필터 설계 방법)

  • Park, Joon Young;Kim, Seok-Min;Seo, SeungGyu;Park, Seong-Soo;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.105-114
    • /
    • 2017
  • This paper proposes a design method of an LCL-filter for grid-tied three-level inverter systems. The demand for three-phase PWM inverters in applications such as wind or solar power generation systems has been increase in recent years. To reduce harmonic components caused by switching operation, such inverters are connected to the grid via an LCL filter. Although there are research results for designing LCL-filter, the modulation method should be fully considered to make the filter perform desired cancellation ability with minimized size. This paper presents the design methodology for an LCL-filter that is optimized for SVM switching operations. The simulation and experimental results verify the validity of the LCL-filter designed with proposed method in this paper.

Consideration of the X-ray Spectrum Change and Resolution According to Added Filters, SID, A-Si (CsITl) in the Imaging System (A-Si(CsITl) 영상시스템에서 부가필터, SID에 따른 X선 스펙트럼변화와 해상력에 대한 고찰)

  • An, Hyeon;Kim, Jung-Hoon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.681-688
    • /
    • 2016
  • This study assess their quality of radiation on analysis of the spectrum of resolution suggesting IEC 61267 in radiation quality that RQA3, RQA5, RQA7, RQA9 and combination of clinical condition using several quality of radiation. In experiments edge method first, the spatial resolution assessment used image of the additional filter and SID is obtained the IEC 62220-1, spatial resolution and sharpness of the obtained image was evaluated in the MTF value 10%(0.1), MTF value 50%(0.5) using a Matlab program. Second, MCNPX simulation used spatial resolution analysis was radiation quality particle fluence and spectrum analysis in energy. As a result, make use of additional filter, image quality evaluation of SID that RQA3 radiation quality combination qualification is higher spatial resolution and sharpness make unused of additional filter and SID 100cm. RQA7 radiation quality combination qualification is higher that spatial resolution make unused of additional filter and SID 150cm. RQA9 radiation quality combination qualification is higher that spatial resolution and sharpness make used of additional filter and SID 180cm. spectrum analysis of radiation quality by reducing consequent errors occurring in the experiment that error due to the reproducibility of the X-ray tube, occur in an error of correction the detector suggest ideal conditions from spectrum analysis through MCNPX simulation. In conclusion, by suggesting spatial resolution and sharpness of result for various radiation quality, It provide basic data that radiation quality condition and quantitative assessment method for laboratory in clinical using detector evaluation.

Experimental Results on an Underwater Acoustic Digital Transceiver Based on DSP (수중 음향 디지털 송수신기의 DSP 구현 및 실험적 고찰)

  • 박종원;최영철;이덕환;김시문;김승근;임용곤
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.296-299
    • /
    • 2003
  • In this paper, an underwater acoustic digital transceiver is designed and implemented by a multiple DSPs system. We have designed a QPSK transmitter based on look-up table and 13-symbols Barker code is used for frame synchronization. Channel distortions are compensated by a wide-band beamformer based on FIR filter and an adaptive equalize. with RLS algorithm. Uniform linear array (ULA) with four elements is used for the spartial signal processing. 1/2 convolutional code and Viterbi decoder are implemented to overcome time-varying multi-path fading. Also, we show experimental results in the underwater anechoic basin at KRISO/KORDl and Goseong, Donghae and Soyang lake of Kangwon-do.

  • PDF

A 3~5 GHz Interferer Robust IR-UWB RF Transceiver for Data Communication and RTLS Applications (간섭 신호에 강인한 특성을 갖는 데이터 통신과 위치 인식 시스템을 위한 3~5 GHz 대역의 IR-UWB RF 송수신기)

  • Ha, Jong Ok;Park, Myung Chul;Jung, Seung Hwan;Eo, Yun Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.70-75
    • /
    • 2014
  • This paper presents a IR-UWB(Impulse Radio Ultra-Wide Band) transceiver circuit for data communication and real time location system. The UWB receiver is designed to OOK(On-Off Keying) modulation for energy detection. The UWB pulse generator is designed by digital logic. And the Gaussian filter is adopted to reject side lobe in transmitter. The measured sensitivity of the receiver is -65 dBm at 4 GHz with 1 Mbps PRF(Pulse Repetition Frequency). And the measured energy efficiency per pulse is 20.6 pJ/bit. The current consumption of the receiver and transmitter including DA is 27.5 mA and 25.5 mA, respectively, at 1.8 V supply.