• Title/Summary/Keyword: 에너지함수

Search Result 1,484, Processing Time 0.024 seconds

Effects of Bias Voltage and Ion-incident Angle on the Etching of Photoresist in a High-density CHF3 Plasma (고밀도 CHF3 플라즈마에서 바이어스 전압과 이온의 입사각이 Photoresist의 식각에 미치는 영향)

  • Kang, Se-Koo;Min, Jae-Ho;Lee, Jin-Kwan;Moon, Sang Heup
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.498-504
    • /
    • 2006
  • The etch rates of photoresist (PR) and the etch selectivity of $SiO_2$ to PR in a high density $CHF_3$ plasma were investigated at different ion-incident angles and bias voltages. A Faraday cage was employed for the accurate control of ion-incident angles. The ion energy was controlled by changing bias voltages. The etch rate of $SiO_2$ continuously decreased with ion-incident angles but the etch rate of PR remained constant up to the middle angle region and decreased afterwards. The etch rates of $SiO_2$ normalized to those at $0^{\circ}$ incident angle changed with the ion-incident angle following a cosine(${\theta}$) curve. On the other hand, the normalized etch rates of the PR changed showing a drastic over-cosine shape in the middle angle region. The etch selectivity of $SiO_2$ to PR decreased with an increase in the ion-incident angle because the etch yields of PR were enhanced by physical sputtering in the middle angle region compared to the case of $SiO_2$ etching. The etch selectivity of $SiO_2$ to PR decreased with an increase in the bias voltage at nearly all ion-incident angles.

A Study on Quantitative Thickness Evaluation Using Film Density Variation in Film Radiography (Film Radiography에서 농도차를 이용한 정량적 두께 평가에 관한 연구)

  • Lee, Sung-Sik;Lee, Jeong-Ki;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.356-362
    • /
    • 1999
  • Based on the assumption that film density increases exponentially with exposure in the industrial radiographic film. an equation representing the characteristic curves of industrial radiographic films and a new density-thickness relation are suggested. The accuracy and reliability of the suggested relation has been tested using radiographs of a carbon steel step wedge with known thickness variation by polychromatic X-ray and ${\gamma}$-ray ($Ir^{192}$). The experimental results were well agreed to the proposed relation in the range of film densities from 1.0 to 3.5 and it was more accurate than the conventional relation. It is also found that ${\gamma}$-ray is more effective in this purpose than polychromatic X-ray, which results in variation of effective linear absorption coefficient due to beam hardening effect as thickness increases. Therefore using the equation and experimentally determined parameters the quantitative evaluation of thickness variation is possible and it can be used to evaluate the depth of local corrosion of pressure vessels in plants.

  • PDF

The Combustion Characteristics of Residual Fuel oil Blended with Fuel Additives (잔사유용 연료첨가제 함유 선박 연료유의 연소특성 연구)

  • Jang, Se-Hyun;Lee, Kyoung-Woo;Kim, Jeong-Ryul;Kim, Jong-Ho;Yoon, Seok-Hun;Cho, Ik-Soon;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.554-563
    • /
    • 2016
  • Ships are capable of operating on residual fuel oil. Recently, various attempts have been made to meet environmental regulations and with ships operating on residual fuel oil. One way of fulfilling these requirements is by using fuel additives. Dispersants and fuel combustion improvers will have a positive effect on improving the combustion characteristics of the residual fuel oil. As such, this study examines fuel oils blended with additives by using fuel combustion analysis (FIA/FCA) and thermogravimetric analysis (TGA). The results of FIA/FCA focuse only on the amount of work done by the fuel oil. Therefore, it is recommended in this study that a new method to evaluate the combustion efficiency via FIA/FCA processes be developed. The analysis with ROHR curve gained by FIA/FCA brought similar results with pressure trace curve therefore it can be said that new analysis method can be reliable. The TGA, analysis process is very sensitive to the evaporation of fuel, for example, which could be addressed. In the performance-related findings of this study, blended samples with additives containing iron compounds showed a greater improvement in early combustion characteristics than samples without additives.

Consideration of the X-ray Spectrum Change and Resolution According to Added Filters, SID, A-Si (CsITl) in the Imaging System (A-Si(CsITl) 영상시스템에서 부가필터, SID에 따른 X선 스펙트럼변화와 해상력에 대한 고찰)

  • An, Hyeon;Kim, Jung-Hoon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.681-688
    • /
    • 2016
  • This study assess their quality of radiation on analysis of the spectrum of resolution suggesting IEC 61267 in radiation quality that RQA3, RQA5, RQA7, RQA9 and combination of clinical condition using several quality of radiation. In experiments edge method first, the spatial resolution assessment used image of the additional filter and SID is obtained the IEC 62220-1, spatial resolution and sharpness of the obtained image was evaluated in the MTF value 10%(0.1), MTF value 50%(0.5) using a Matlab program. Second, MCNPX simulation used spatial resolution analysis was radiation quality particle fluence and spectrum analysis in energy. As a result, make use of additional filter, image quality evaluation of SID that RQA3 radiation quality combination qualification is higher spatial resolution and sharpness make unused of additional filter and SID 100cm. RQA7 radiation quality combination qualification is higher that spatial resolution make unused of additional filter and SID 150cm. RQA9 radiation quality combination qualification is higher that spatial resolution and sharpness make used of additional filter and SID 180cm. spectrum analysis of radiation quality by reducing consequent errors occurring in the experiment that error due to the reproducibility of the X-ray tube, occur in an error of correction the detector suggest ideal conditions from spectrum analysis through MCNPX simulation. In conclusion, by suggesting spatial resolution and sharpness of result for various radiation quality, It provide basic data that radiation quality condition and quantitative assessment method for laboratory in clinical using detector evaluation.

The Design of Optimal Filters in Vector-Quantized Subband Codecs (벡터양자화된 부대역 코덱에서 최적필터의 구현)

  • 지인호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.97-102
    • /
    • 2000
  • Subband coding is to divide the signal frequency band into a set of uncorrelated frequency bands by filtering and then to encode each of these subbands using a bit allocation rationale matched to the signal energy in that subband. The actual coding of the subband signal can be done using waveform encoding techniques such as PCM, DPCM and vector quantizer(VQ) in order to obtain higher data compression. Most researchers have focused on the error in the quantizer, but not on the overall reconstruction error and its dependence on the filter bank. This paper provides a thorough analysis of subband codecs and further development of optimum filter bank design using vector quantizer. We compute the mean squared reconstruction error(MSE) which depends on N the number of entries in each code book, k the length of each code word, and on the filter bank coefficients. We form this MSE measure in terms of the equivalent quantization model and find the optimum FIR filter coefficients for each channel in the M-band structure for a given bit rate, given filter length, and given input signal correlation model. Specific design examples are worked out for 4-tap filter in 2-band paraunitary filter bank structure. These optimum paraunitary filter coefficients are obtained by using Monte Carlo simulation. We expect that the results of this work could be contributed to study on the optimum design of subband codecs using vector quantizer.

  • PDF

The Structures and Thermal Properties of Divalent Ion Exchanged Zeolite A (2가 이온 치환 제올라이트 A 의 구조와 열적 성질)

  • Jong Yul Park;Yang Kim;Un Sik Kim;Sang Gu Choi
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.357-365
    • /
    • 1989
  • The positional parameters of framework atoms, cations, and water molecules in hydrated and dehydrated $Mg_4Na_4-A$, $Ca_6-A$, $Zn_5Na_2-A$ and $Co_4Na_4-A$ were determined by the optimization technique using some potential energy functions and VAIOA optimization program. Upon dehydration, cations in hydrated states move toward the framework oxygens of 6 rings. Frameworks of fully dehydrated zeolite A are more stable than those of fully dehydrated divalent cation exchanged Zeolite A. There are three different kinds of water molecules in divalent cation exchanged Zeolite A; W(III) (water molecules having hydrogen bonds), W(II) (water molecules associated with $Na^+$ ions), and W(I) (water molecules associated with divalent cations). Three different DTA endothermic peaks were observed corresponding to the dehydration of three different kinds of water molecules in divalent cation exchanged Zeolite A.

  • PDF

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Growth and Development of Acartia steueri (Copepoda: Calanoida) in the Laboratory (실험실에서 요각류 Acartia steueri의 성장과 발생)

  • KANG Hyung-Ku;KANG Yong Joo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.6
    • /
    • pp.842-851
    • /
    • 1998
  • Development and growth of Acartia steueri from Ilkwang Bay, southeastern coast of Korea, were determined under various temperatures and food condition (Isochrysis galbana and Dunaliella salina) in the laboratory. Relationship between egg hatching time ($D_E$, day) and temperature (T, $^{\circ}C$) was $D_E=744(T+3.5)^{-1.97}$. Mean hatching success was $88.4\%$ in temperature range of $8.4\~26.2^{\circ}C$. This suggests that A. steueri may be adapted to the temperature ranges in temperate regions. Post-embryonic development pattern was equiproportional rather than isochronal, with longer stage duration of copepodites than that of the nauplii. Stage duration of NI was the shortest of all developmental stages, while the duration of NII was the longest in duration of the other nauplii. Male was morphologically distinguished from female in CIV stage, and male was developed faster than female. Median development time at a given temperature was calculated from the Belehradek equation by proper multiplication of proportional constant for embryonic development. Body carbon weight at $19.1^{\circ}C$ was increased exponentially with time. Mean specific growth rate of nauplii (0.200 $d^{-1}$), except for NI stage, was not significantly different from that of copepodites (0.190 $d^{-1}$), with the lowest rate in NVI stage (0.107 $d^{-1}$), probably due to energy consumption for metamorphosis rather than somatic growth. The results suggest that although the development pattern determined in this study was not identical with Uye's result for A. steueri (e.g. Uye, 1980b), median development time may be applicable to calculate the stage duration of A. steueri in this study area.

  • PDF

Fiber Distribution Characteristics and Flexural Performance of Extruded ECC Panel (압출성형 ECC 패널의 섬유분포 특성과 휨 성능)

  • Lee, Bang-Yeon;Han, Byung-Chan;Cho, Chang-Geun;Kwon, Young-Jin;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.573-580
    • /
    • 2009
  • This paper presents the mix composition, production method, and curing condition applied to the extruded ECC(Engineered Cementitious Composite) panel which are able to exhibit multiple cracking and potential pseudo strain-hardening behavior. In addition to the production technique of extruded ECC panel, the effect of fiber distribution characteristics, which are uniquely created by applying extrusion process, on the flexural behavior of the panel is also focussed. In order to demonstrate fiber distribution, a series of experiments and analyses, including image processing/analysis and micro-mechanical analysis, was performed. The optimum mix composition of extruded ECC panel was determined in terms of water matrix ratio, the amount of cement, ECC powder, and silica powder. It was found that flexural behavior of extruded ECC panel was highly affected by the slight difference in mix composition of ECC panel. This is mainly because the difference in mix composition results in the change of micro-mechanical properties as well as fiber distribution characteristics, represented by fiber dispersion and orientation. In terms of the average fiber orientation, the fiber distribution was found to be similar to the assumption of two dimensional random distribution, irrespective of mix composition. In contrast, the probability density function for fiber orientation was measured to be quite different depending on the mix composition.

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.