It is essential to know the heat transfer characteristics at the absorber plate of Flat-plate solar collector for optimum design. For flat-plate solar collector, it is difficult to experimentally study the effect for the Reynolds number of riser considering low mass flow rate being applied into the collector with one riser tube. So, this study were performed to show the heat transfer characteristics of flat-plate solar collector with single absorber plate and riser for various Reynolds number at riser using commercial code FLUENT 6.0. The base collector size is chosen with $0.4m^2$ as 0.2m by 2m with single riser in this study, Reynolds number at riser is from 200 to 1200 including about 530 at typical flat-plate collector with 10 risers considering the mass flow rate of 0.02kg/s per collector area for the certificate test Through the simulation, the results were presented as the temperature distribution at the absorber plate for various flow rate and solar irradiance conditions, then showed the effective length scale of the absorber plate The real solar irradiation condition is assumed as the constant heat flux condition of $500w/m^2$ considering the annual average solar irradiance in Korea.
As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.
한국형차세대원자로 APR-1400의 안전감압계통이 작동하면 물, 공기 및 증기가 sparger를 통해 격납건물 내 핵연료재장전 수조로 차례로 방출된다. 방출 과정 중 생기는 여러 현상 중에서 수조 내의 공기 기포군은 저주파, 고진폭의 진동 하중을 발생하며, 주파수가 침수 구조물의 고유 주파수와 거의 같은 경우에는 구조물에 심각한 영향을 줄 수 있다. 이러한 현상은 복잡하기 때문에 주파수와 하중에 대한 규명은 주로 실험에 의존해 왔으며 수치해석적 연구는 이루어지지 않았다. 본 연구에서는 sparger를 통해 수조 내로 방출되는 공기 기포군의 거동에 대한 수치해석을 상용 열수력 해석 코드인 FLUENT Version 4.5를 사용하여 수행하였다. 다상유동 해석모델중 VOF(Volume Of Fluid)모델을 사용하여 물, 공기 및 증기 등의 다상유동을 모의하였다. 해석결과를 sparger 개발을 위해 ABB-Atom이 수행하였던 실험결과와 비교하여 만족할만한 결과를 얻었다.
IGCC용 가스터빈 연소기의 중발열량 가스 연료 대체성 및 호환성 검토를 위한 전산유체역학적 연구를 수행하였다. 연소기 전산해석 방법은 기존의 상용 CFD코드의 해석체계에 중발열량 가스연료의 화학반응 모델 및 fuel NOx 모델등을 추가적으로 결합하여 구성하였다. 본 해석방법을 이용하여, 천연가스와 IGCC 용 대체가스(석탄가스, 중잔사유 가스) 연소시의 연소기 내부 유동속도, 화학종, 온도 분포들과 화염 형상 및 거동을 비교하였고, 더 나아가 NOx 생성특성과 터빈과의 matching 조건도 분석하였다. 이러한 전산해석결과들을 바탕으로, 본 연구는 중발열량 가스를 대체연료로 사용하는 IGCC용 가스터빈 연소기의 설계 개선 및 재설계 방향을 제시하였다.
배선용 차단기(MCCB)는 과부하 및 단로 등의 이상 상태시 전류를 차단하는 기구로, 오작동시에는 중대사고를 초래한다. MCCB를 개발하는데 있어서 고전류 및 향상된 방열성능은 소형화 및 성능향상을 필요로 하는 기기의 안전기능 및 신뢰성을 확보하는데 그 중요성이 더해 가고 있다. 또한, MCCB를 설계하는데 있어 온도상승 요인을 고려하는 것은 매우 중요하다. 온도상승의 주된 원인은 기기 내부저항, 특히 접속부와 접촉부로부터의 저항을 들 수 있는데, 전류, 시간, 접촉면의 형상, 그리고 사용전압에 의하여 영향을 받는다 본 연구에서는 MCCB 내부 온도분포를 예측하기 위하여 상용코드ICEPAK을 이용하여 수치해석을 수행하였다. 해석결과의 타당성을 검증하기 위하여 동일 모델을 사용한 실험결과와 비교하였는데, 일치된 결과를 얻을 수 있었다.
국내에 천연가스버스가 보급된 이래 5차례의 용기파열 사고가 발생하였는데 그중 2005년 8월 전주 덕진충전소에서 발생한 용기파열사고는 CNG용기의 라이너를 감싸고 있는 복합재료가 손상되어 발생한 사고로 보고되었다. 복합재료용기의 외피손상이 원인이 되어 발생한 사고사례는 해외에서 약 13건이 보고되었다. CNG용기 외피손상은 용기룰 고정하는 스트랩과 밀접한 관련이 있다. 용기고정이 불완전하면 슬립이 발생하고 이는 복합재의 손상으로 이어진다. 본 연구에서는 ISO 19078, CGA C6.4 등 국제코드의 규정을 고려하여 국내에서 제조된 Type 2, 3, 4 용기와 외국에서 생산된 Type 3 용기를 대상으로 결함깊이, 길이, 넓이에 따른 복합재료 결함 내구성시험을 수행하여 CNG용기의 내구성능을 평가하였고, 시험과 동일한 조건으로 복합재료 손상결함 조건을 컴퓨터로 전산모사하여 시험결과의 타당성과 유효성을 비교 검증하였다. 실험결과, Type 2 용기의 경우, 11,250회의 최소반복가압 회수를 충족하였으나 외피손상부와 반복가압에 따른 실제누출부위가 일치하지 않아 실험조건을 달리한 추가실험이 요구되었다. Type 3 용기의 경우에는 복합재 결함부위와 누수부위가 일치된 시험용기의 수는 67%정도로, 복합재료 용기의 수명을 저하시키는 원인으로 라이너와 외피손상이 서로 밀접한 관련이 있음을 확인하였다. Type 4 용기는 국제기준에서 요구하는 반복횟수를 만족하였고, 손상깊이 0.75mm와 1.25mm에서 반복가압회수가 60,000회 이상이 되어도 누설이 발생되지 않았다. 이는 라이너의 재질이 폴리머로서 균일한데다 탄소섬유 복합재료층 위에 유리섬유 복합재료 층이 1.5mm 정도 추가로 적층되어 있어서 3등급의 손상결함(결함깊이 1.25mm)에서도 구조 층이 전혀 손상되지 않은 것으로 판단되며, 이는 Type 2 용기의 강재라이너나 Type 3의 알루미늄 라이너와 비교하여 Type 4 용기의 폴리에틸렌 라이너의 물성이 반복성능이 탁월함을 확인할 수 있었다.
진동수주형 파력발전장치에서 공기실 내의 수면 변화와 덕트 내 유량의 왕복유동은 시스템의 작동 성능을 결정짓는 매우 중요한 요소이다. 공기실 내의 수면 변화를 고찰하기 위하여 상용 CFD 코드인 Fluent 6.2를 이용하여 구현한 수치조파수조를 사용하였다. 수치조파수조의 지배방정식은 연속방정식과 Reynolds 평균 N-S 방정식이고 자유수면은 Two-phase VOF 기법을 이용하여 추적하였다. 공기실 내의 수면 변화와 공기실 윗부분에 설치된 덕트 내의 왕복유량을 계산하여 고찰하였고, 계산의 정확도를 검증하기 위하여 실험결과와 비교 분석을 수행하였다. 또한 동일한 입사파 조건에서 공기실 - 덕트 시스템의 노즐 비율이 시스템이 미치는 영향을 고찰하여 분석을 하였다.
본 논문은 조류발전을 위하여 가장 보편적으로 사용되는 수직축 조류발전 터빈의 하나인 다리우스 터빈의 효율에 미치는 다양한 설계변수의 영향을 살펴보기 위하여 수행하였다. 날개 수, 코드 길이, 피치 및 캠버를 설계변수로 채택하였으며, 2차원 및 3차원 비정상 난류유동해석을 위하여 FLUENT의 RANS방정식과 k-e 난류모델을, 격자계 모델링을 위하여 GAMBIT을 이용하였다. 기본적인 수치해석방법은 정현주 등(2009)을 참조하였다. 설계변수 변경에 따른 방대한 계산 량을 감안하여 수치해석의 신뢰도가 허락하는 범위에서 대부분 2차원 해석으로 결과를 도출하였다. 본 연구에서 제시한 설계변수의 최적화를 통하여 기준모형보다 월등한 성능을 보이는 고효율 수직축 터빈 모델을 제시할 수 있었다.
The interest of New Renewable Energy is increasing globally because of the increment of the uncertainty for the energy's supply and demand, and the increment of the frequency in weather anomaly and its damages. One of the New Renewable Energies, Hydrogen receives attention as the future energy that can deal with global environment regulation. Fuel Cell Electric Vehicle (FCEV) is an environment-friendly vehicle that uses Hydrogen as fuel. The electric power for FCEV is generated by chemical reaction with Oxygen from the air and Hydrogen. Hyundai Motor Company (HMC) has developed a proprietary fuel cell system since 2005. In 2012, HMC is the first car maker that mass-produces the ix35 FCEV to the worldwide such as North America, Europe, etc. In order to develop and improve the FCEV technology, data acquisition and analysis of the driving vehicle information is essential. Therefore, the monitoring system is developed, which is consist of datalogger, Automatic Vehicle Location (AVL) server and main server. Especially, WCDMA technology is integrated into the system which enables the data analysis without any restriction of time and region. The main function of the system is the analysis of the driving pattern and the component durability, and the safety monitoring. As a result, ix35 FCEV has successfully developed by using the developed monitoring system. The system is going to take an advantage of development in the future FCEV technology.
본 연구에서는 연구에서는 Ce:GAGG 섬광체, 광섬유 그리고 광전자증배관을 이용하여 광섬유 검출기를 제작하였다. 섬광체의 단결정 크기는 MCNPX 코드를 이용하여 섬광체 깊이에 따른 감마선 계수효율을 전산모사하여 $3{\times}3{\times}20mm^3$로 설정하였다. 제작된 검출기는 표준 감마선원인 $^{137}Cs$과 $^{133}Ba$을 이용하여 세기의 따른 선형성 평가와 거리 변화에 따른 계수량 변화 측정을 하였다. 그 결과 추세선식 R-square 값이 0.99741로 매우 좋은 응답선형성을 보였고, 거리에 따른 검출 특성 또한 MCNPX값과 비교하였을 때 2% 이하로 좋은 검출특성을 보였다. 또한 단일선원과 혼합선원에서의 감마선 에너지 분광 결과 $^{137}Cs$은 662keV에서 그리고 $^{133}Ba$은 356keV에서 감마선 에너지 피크를 확인하였다. 광섬유 검출기를 사용한다면 작업자의 작업시간과 피폭을 줄여줄 것으로 보인다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.